HYRIG can supply the FESTO VSVA-B-P53U-ZD-A1-1T1L solenoid valve. The FESTO VSVA-B-P53U-ZD-A1-1T1L is a 5/3 pressurised directional control valve with a standard nominal flow rate of 1000 l/min, a 26 mm valve width to ISO 15407-2, and a 24 VDC solenoid with an M12 central plug. In the centre position, both actuator ports remain connected to supply, holding a double-acting cylinder actively pressurised on both sides — and the -0.9 bar lower pressure limit allows the valve to be used in vacuum circuits as well as compressed air systems.
| Valve function | 5/3 pressurised (mid-position pressure) |
| Standard nominal flow rate | 1000 l/min |
| Valve width | 26 mm (ISO 15407-2) |
| Operating pressure | -0.9 bar … 10 bar |
| Pilot pressure | 3 bar … 10 bar |
| Supply voltage | 24 VDC |
| Electrical connection | M12 central plug |
| Protection class | IP65 |
| Order code | 539160 |
| Model | Function | Flow rate | Standard | Pressure range | Order code |
|---|---|---|---|---|---|
| VSVA-B-P53U-ZD-A1-1T1L | 5/3 pressurised | 1000 l/min | ISO 15407-2 | -0.9-10 bar | 539160 |
| VSVA-B-P53E-ZD-A1-1T1L | 5/3 exhausted | 1000 l/min | ISO 15407-2 | -0.9-10 bar | 539161 |
| VSVA-B-M52-MZD-A1-1T1L | 5/2 monostable | 1100 l/min | ISO 15407-2 | -0.9-10 bar | 539159 |
Explore the full range in the FESTO VSVA valve terminal overview.
Data source: Technical data table.
| Item | Value |
|---|---|
| Valve width | 26 mm |
| Pneumatic connection | Sub-base, 26 mm to ISO 15407-2 |
| Electrical connection | M12 central plug |
| Protection class | IP65 |
| Operating temperature | -5 °C … +50 °C |
| Media | Compressed air to ISO 8573-1:2010 [7:4:4] |
The VSVA-B-P53U-ZD-A1-1T1L is a 5/3 pressurised piston spool valve on the ISO 15407-2 sub-base. In the centre position, port 1 (supply) remains connected to both port 4 and port 2, so a double-acting cylinder is held by supply pressure on both sides. The ISO 15407-2 standard differs from ISO 15407-1 in the pilot port arrangement and the sub-base interface, so this valve cannot be mixed with ISO 15407-1 slices on the same manifold without an adapter.
The operating pressure range extends to -0.9 bar, which means the valve can also be used to control vacuum circuits — for example, a vacuum ejector or a vacuum holding circuit — in addition to compressed air actuators up to 10 bar. The 26 mm width provides a 1000 l/min standard nominal flow rate, and the M12 central plug carries both solenoid signals and LED status indicators.
Not sure whether the ISO 15407-2 interface matches your existing manifold, or need the ISO 15407-1 variant instead? Send your manifold standard, cylinder bore, holding requirement, and vacuum requirement, and we will confirm the valve function and interface.
Q: What is the flow rate of the Festo VSVA-B-P53U-ZD-A1-1T1L?
A: 1000 l/min standard nominal flow rate, standardised to DIN 1343.
Q: What is the difference between ISO 15407-1 and ISO 15407-2 for VSVA valves?
A: ISO 15407-1 and ISO 15407-2 use different sub-base interfaces and pilot port arrangements. A valve on one standard cannot be mounted directly on a manifold for the other without an adapter. Confirm the manifold standard before ordering.
Q: Can the VSVA-B-P53U-ZD-A1-1T1L be used in vacuum circuits?
A: Yes. The operating pressure range extends to -0.9 bar, so the valve can control vacuum ejectors and vacuum holding circuits in addition to compressed air actuators.
Q: Does the VSVA-B-P53U-ZD-A1-1T1L use the same manifold as the P53E-ZD exhausted-centre variant?
A: Yes. Both use the 26 mm ISO 15407-2 sub-base. Confirm the function-specific port pattern before mixing centre functions on one manifold.
Q: What is the lead time for Festo VSVA-B-P53U-ZD-A1-1T1L?
A: Standard lead time is 5–6 weeks from order confirmation, based on the quoted supply status.
For FESTO VSVA-B-P53U-ZD-A1-1T1L selection and manifold configuration, contact HYRIG: info@hyrig.com.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.