Lean Amine Regenerator Bottom Pump – API 610 OH2 / BB3 / VS4 for Stripped Amine Transfer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 lean amine regenerator bottom pump for continuous removal of hot stripped lean amine (MDEA/MEA/DEA) from the bottom of an amine stripper/regenerator. OH2 single‑stage, BB3 high‑head multistage, VS4 vertical sump. 316L stainless steel (S‑8) wetted parts. API 682 Plan 53B dual pressurized seals. Handles temperatures to 130°C. Flows 10–1500 m³/h, heads 20–1500 m. 20‑year design life.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Lean Amine Regenerator Bottom Pump is specifically designed to continuously remove the regenerated (stripped) lean amine from the bottom of an amine regenerator (stripper) column in natural gas sweetening plants, refinery hydrodesulfurization (HDS) units, and carbon capture (CCUS) facilities. After rich amine is stripped of H₂S and CO₂ using heat and steam, the resulting hot lean amine collects at the column base. This pump transfers the lean amine either to the lean amine charge pump for re‑circulation to the absorber, or directly to the reboiler to generate stripping steam.

The service is demanding: the fluid is hot (100–130°C), corrosive, may contain residual H₂S, and must be handled with absolute reliability to prevent plant shutdown. All pumps are fully compliant with API 610 11th/12th edition (ISO 13709) standards – guaranteeing a 20‑year design life and minimum 3‑year uninterrupted operation. Available in three API 610 configurations (OH2, BB3, VS4), the lean amine regenerator bottom pump covers all column base transfer requirements.

Pump Configurations for Lean Amine Regenerator Bottom Service

Pump TypeConfigurationBest Application
OH2 (Preferred)Overhung, centreline‑mounted, single‑stageStandard lean amine transfer to reboiler or charge pump (heads ≤150 m, flows 10–600 m³/h)
BB3Axially split, multistage, between bearingsHigh‑head transfer (>150 m) where lean amine must be pumped to an elevated reboiler or distant charge pump
VS4Vertical suspended sump / can typeLow NPSHa at column base (shallow sump or vacuum operation); space‑constrained or fire‑code installations

Key Technical Specifications

ParameterOH2BB3VS4
Flow range10 – 600 m³/h50 – 1500 m³/h10 – 750 m³/h
Head range20 – 260 m (typical 50–150 m)100 – 1500 m15 – 280 m
Pressure ratingUp to 64 barUp to 150 barUp to 40 bar
Temperature–45 to +200°C–45 to +200°C–46 to +260°C
Speed1,450 / 2,950 rpm1,450 / 2,950 rpm1,450 / 2,950 rpm

Materials – API 610 Table H

Lean amine at regenerator base temperature (100–130°C) is corrosive due to residual H₂S, CO₂, and heat‑stable salts. 316L stainless steel (API 610 Class S‑8) is the minimum standard. Carbon steel is not acceptable.

ComponentMaterial (Standard)Upgrade Option
Casing316L SS (CF3M)Duplex (D‑1/D‑2), Super Duplex (U‑8)
Impeller316L SSDuplex, Super Duplex, 17‑4 PH
Shaft316 SS or 4140 with coating17‑4 PH, Duplex SS
Wear rings316L SS + Stellite hard‑facingTungsten carbide
Gaskets / O‑ringsSpiral wound (graphite) / FKMAflas for higher temperatures

For lean amine with H₂S partial pressure above NACE limits, NACE MR0175 / ISO 15156 certification is required.

Mechanical Seals – API 682 Compliance

Residual H₂S and high temperature demand robust sealing. Dual pressurized seals (API 682 Arrangement 3) with Plan 53B are strongly recommended.

Seal ArrangementAPI 682 PlanApplication
Dual pressurised (Arr. 3)Plan 53BRecommended – zero emissions, barrier fluid pressure > process, ideal for hot lean amine
Tandem seal (Arr. 2)Plan 52Acceptable only for very low H₂S, not preferred
Single seal (Arr. 1)Plan 11 / 23Not recommended for hot H₂S service

Plan 53B uses a bladder accumulator to keep barrier fluid pressure above process pressure, eliminating amine/H₂S leakage. Seal faces: silicon carbide (SiC) / SiC. Elastomers: FKM for up to 120°C; Aflas for higher temperatures.

NPSH Considerations

The pump takes suction from the regenerator base. Column pressure is typically near atmospheric, liquid level may be limited (2–6 meters), and the fluid is hot with dissolved gases. Low NPSH is a common challenge.

  • Use short, insulated suction piping.

  • Calculate NPSHa at bubble point – do not assume subcooling.

  • Select low‑NPSHr impeller or inducer.

  • Maintain NPSHa ≥ NPSHr + 1.0 m per API 610.

  • If NPSHa is insufficient, use a VS4 vertical pump.

Minimum Flow Protection

The pump runs continuously. An automatic recirculation valve (ARC) or bypass line with orifice must return minimum flow to the column base if the main discharge valve closes.

Applications for Lean Amine Regenerator Bottom Pump

IndustryProcessFluidConfiguration
Natural gas sweeteningAmine regenerationHot lean MDEA / MEAOH2
Refinery HDSAmine strippingHot lean MDEA / DEAOH2 (or BB3 for high head)
CCUS (carbon capture)MEA regenerationHot lean MEAOH2
Claus tail gas treatmentTGTU amine regeneratorHot lean MDEAOH2

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Continuous operation: Minimum 3 years uninterrupted service

  • Bearing life: L10 ≥25,000 hours

  • Critical speed: ≥120% of maximum operating speed

  • Centreline mounting (OH2/BB3): Essential for hot service (100–130°C)

  • Hydrostatic test: 1.5x design pressure

  • Performance test: Water per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 full traceability

  • NACE MR0175 / ISO 15156 available for sour lean amine

Why Choose Our Lean Amine Regenerator Bottom Pump?

  • Full API 610 compliance (OH2 / BB3 / VS4) – 11th/12th edition ISO 13709, 20‑year life

  • 316L stainless steel (S‑8) as standard – proven resistance to hot lean amine corrosion

  • API 682 Plan 53B dual pressurised seals – zero emissions, safe residual H₂S containment

  • Broad hydraulic coverage – flows 10–1500 m³/h, heads 20–1500 m

  • Low NPSH designs – inducer option for low‑elevation column bases

  • Centreline mounting – maintains alignment through thermal cycling

  • Easy maintenance – back pull‑out (OH2), axial split (BB3), vertical withdrawable (VS4)

  • Minimum flow protection – ARC or bypass integrated

  • NACE MR0175 / ISO 15156 compliant options

  • Field proven – thousands operating in gas plants, refineries, and CCUS facilities

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller)1 set
Gasket / O‑ring kit (full set)1 set
Inducer (if fitted)1 set

Get a Quote or Engineering Support

For selection of the correct Lean Amine Regenerator Bottom Pump for your amine regeneration unit – including column base conditions (temperature, pressure, fluid composition, NPSHa), material selection (316L SS, duplex, or NACE MR0175), API 682 seal plan (Plan 53B), and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support gas sweetening, refinery HDS, carbon capture, and tail gas treatment projects worldwide with reliable API 610 lean amine regenerator bottom pumps – safe, efficient transfer of hot stripped lean amine from regenerator base to reboiler or charge pump.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit