The Regenerator Base Pump is a critical pump located at the bottom (base) of a regenerator (stripper) column in gas sweetening, refinery hydrodesulfurization (HDS), carbon capture (CCUS), and solvent regeneration processes. Its primary function is to continuously remove the stripped liquid – typically hot lean amine (MDEA, MEA, DEA that has been regenerated) – from the column base and transfer it either to the reboiler for steam generation or to the lean amine charge pump for circulation back to the absorber. The pump may also handle other regenerator base liquids such as stripped sour water or glycol.
The fluid at the regenerator base is hot (typically 100–130°C), may contain residual H₂S and CO₂, is corrosive, and must be handled safely and reliably to maintain continuous plant operation. All pumps are fully compliant with API 610 11th/12th edition (ISO 13709) standards – ensuring a 20‑year design life and a minimum 3‑year uninterrupted operation. Available in three API 610 configurations – OH2 (single‑stage overhung), BB3 (multistage between bearings), and VS4 (vertical sump) – the Regenerator Base Pump covers all typical column bottom transfer duties.
| Pump Type | Configuration | Best Regenerator Base Application |
|---|---|---|
| OH2 (Preferred) | Overhung, centreline‑mounted, single‑stage | Standard lean amine transfer to reboiler or lean charge pump (heads ≤150 m, flows 10–600 m³/h) |
| BB3 | Axially split, multistage, between bearings | High‑head transfer (>150 m) when the reboiler is elevated or the charge pump requires high suction pressure |
| VS4 | Vertical suspended sump / can type | Low NPSHa at column base (e.g., shallow sump or vacuum column); fire‑code or space‑constrained installations |
| Parameter | OH2 | BB3 | VS4 |
|---|---|---|---|
| Flow range | 10 – 600 m³/h | 50 – 1500 m³/h | 10 – 750 m³/h |
| Head range | 20 – 260 m (typical 50–150 m) | 100 – 1500 m | 15 – 280 m |
| Pressure rating | Up to 64 bar | Up to 150 bar | Up to 40 bar |
| Temperature | –45 to +200°C | –45 to +200°C | –46 to +260°C |
| Speed | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm |
Lean amine at regenerator base temperature (100–130°C) is corrosive, especially in the presence of residual H₂S, CO₂, and heat‑stable salts. 316L stainless steel (API 610 Class S‑8) is the minimum standard. Carbon steel is not acceptable.
| Component | Material (Standard) | Upgrade Option |
|---|---|---|
| Casing | 316L SS (CF3M) | Duplex (D‑1/D‑2), Super Duplex (U‑8) |
| Impeller | 316L SS | Duplex, Super Duplex, 17‑4 PH |
| Shaft | 316 SS or 4140 with coating | 17‑4 PH, Duplex SS |
| Wear rings | 316L SS + Stellite hard‑facing | Tungsten carbide |
| Gaskets / O‑rings | Spiral wound (graphite) / FKM | Aflas for higher temperature |
For lean amine with H₂S partial pressure above NACE limits, NACE MR0175 / ISO 15156 certification is required.
Although lean amine has lower H₂S concentration than rich amine, residual H₂S plus high temperature requires robust sealing. Dual pressurized seals (API 682 Arrangement 3) with Plan 53B are strongly recommended. For very low H₂S and well‑ventilated areas, a tandem seal (Plan 52) may be acceptable, but Plan 53B is the industry standard for safety and emissions compliance.
| Seal Arrangement | API 682 Plan | Application |
|---|---|---|
| Dual pressurised (Arr. 3) | Plan 53B | Recommended – zero emissions, barrier fluid pressure > process, ideal for hot lean amine |
| Tandem seal (Arr. 2) | Plan 52 | Acceptable only for lowest H₂S residual, not preferred |
| Single seal (Arr. 1) | Plan 11 / 23 | Not recommended for hot amine (Plan 23 cooled may be used for non‑H₂S service) |
Plan 53B provides barrier fluid pressurised above process pressure using a bladder accumulator, eliminating any leakage of amine or H₂S. Seal faces: silicon carbide (SiC) / SiC. Elastomers: FKM (Viton) for up to 120°C; Aflas for higher temperatures.
The regenerator base pump typically takes suction from the bottom of a column operating near atmospheric pressure (or slight vacuum in some designs). The liquid level above the pump centreline may be only 2–6 meters, providing limited NPSHa. The fluid is hot and near its bubble point – dissolved gases (CO₂, H₂S, methane) flash easily.
Keep suction piping as short and direct as possible, properly insulated.
Calculate NPSHa at the bubble point – do not assume subcooling.
Select a low‑NPSHr impeller or add an inducer if margin is insufficient.
Ensure NPSHa ≥ NPSHr + 1.0 m per API 610.
Consider a VS4 vertical pump if NPSHa from horizontal OH2 is inadequate.
The regenerator base pump operates continuously while the plant is online. If the downstream valve (to reboiler or charge pump) closes, the pump must be protected. An automatic recirculation valve (ARC) or a continuous bypass line with orifice must return the minimum required flow to the column base.
| Industry | Process | Fluid | Pump Configuration |
|---|---|---|---|
| Natural gas sweetening | Amine regeneration | Lean MDEA / MEA (100–130°C) | OH2 (standard) |
| Refinery HDS | Amine stripping | Lean MDEA / DEA | OH2 or BB3 |
| CCUS (carbon capture) | MEA regeneration | Lean MEA | OH2 |
| Sour water stripping | Sour water stripper | Stripped sour water | OH2 (316L SS or duplex) |
| Glycol dehydration | Glycol regenerator | Lean glycol | OH2 (carbon steel or 316L) |
Design life: 20 years minimum
Continuous operation: Minimum 3 years uninterrupted service
Bearing life: L10 ≥25,000 hours
Critical speed: ≥120% of maximum operating speed
Centreline mounting (OH2/BB3): Essential for hot service (100–130°C)
Hydrostatic test: 1.5x design pressure
Performance test: Water per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 full traceability
NACE MR0175 / ISO 15156 available for sour lean amine
Full API 610 compliance (OH2 / BB3 / VS4) – 11th/12th edition ISO 13709, 20‑year life
316L stainless steel (S‑8) as standard – proven corrosion resistance in hot lean amine
API 682 Plan 53B dual pressurised seals – zero emissions, safe containment of residual H₂S
Broad hydraulic coverage – flows 10–1500 m³/h, heads 20–1500 m
Low NPSH designs – inducer option for low‑elevation column bases
Centreline mounting – maintains alignment during thermal cycling (up to 200°C)
Easy maintenance – back pull‑out (OH2), axial split (BB3), vertical withdrawable (VS4)
Minimum flow protection – ARC or bypass integrated
NACE MR0175 / ISO 15156 compliant options
Field proven – thousands of regenerator base pumps in gas plants and refineries worldwide
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 53B ready) | 1 set |
| Bearing set (radial + thrust) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Gasket / O‑ring kit (full set) | 1 set |
| Inducer (if fitted) | 1 set |
For selection of the correct Regenerator Base Pump for your amine or solvent regeneration unit – including column bottom conditions (temperature, pressure, fluid composition, H₂S residual), NPSHa calculation, material selection (316L SS, duplex, or NACE MR0175), API 682 seal plan (Plan 53B), and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
Our engineers support gas sweetening, refinery HDS, carbon capture, and solvent regeneration projects worldwide with reliable API 610 regenerator base pumps – safe, corrosion‑resistant transfer of hot lean amine from column base to reboiler or charge pump.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.