API 610 regenerator sump pump for collecting amine drips, seal leaks, sample drains, and spillage from the regenerator (stripper) area in gas sweetening and refinery amine units. VS4 vertical suspended sump configuration (standard), OH2 horizontal option for dry pits. 316L stainless steel (S-8) wetted parts. API 682 Plan 53B dual seals for H₂S containment. Flows 5–400 m³/h, heads 15–150 m. 20-year design life.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Regenerator Sump Pump is a dedicated pump for collecting and transferring amine solutions – primarily lean amine – from sumps, drain pits, and collection basins located around the regenerator (stripper) column in gas sweetening plants, refinery hydrodesulfurization (HDS) units, and carbon capture (CCUS) facilities. The regenerator area collects drips from flanges, valve packing, pump seals, sample points, and occasional spillage during maintenance. These liquids are typically hot (up to 120°C), may contain residual H₂S, and are corrosive.

To ensure safe, emissions‑free, and reliable collection of these hazardous fluids, the pump is manufactured to API 610 11th/12th edition (ISO 13709) standards – guaranteeing a 20‑year design life and minimum 3‑year uninterrupted operation. The VS4 vertical suspended sump pump is the preferred configuration, with an OH2 horizontal option for dry‑pit installations.

Pump Configurations for Regenerator Sump Service

Pump TypeConfigurationBest Application
VS4 (Preferred)Vertical suspended, wet pit, single or multistage, diffuser typeBelow‑grade sumps and drain pits adjacent to regenerator; low NPSHa; fire‑code compliance; space‑constrained areas
OH2 (Alternative)Overhung, centreline‑mounted, horizontalAbove‑grade small collection tanks or dry pits where sump is pumped via short suction line

Key Technical Specifications (VS4 Standard)

ParameterRange
Flow range5 – 400 m³/h (customisable)
Head range15 – 150 m (typical for sump evacuation)
Pressure ratingUp to 40 bar (580 psi)
Temperature range–46°C to +260°C
Discharge sizes40 mm to 150 mm (1.5" to 6")
Pump column lengthCustom – up to 6 meters (longer available)
Stages1 to 6 (depending on head)
Speed1,450 / 2,950 rpm

Materials – API 610 Table H

Regenerator sump fluid is typically lean amine (MDEA, MEA, DEA) with residual H₂S, water, and possibly heat‑stable salts. The fluid is hot (80–120°C). 316L stainless steel (API 610 Class S‑8) is the minimum standard.

ComponentMaterial (Standard)Upgrade Option
Pump column / discharge pipe316L stainless steelDuplex (D‑1)
Diffuser casings316L SS (CF3M)Duplex
Impellers316L SSDuplex, Super Duplex
Shaft (line shaft)316 SS17‑4 PH, Duplex
Discharge head316L SS or carbon steel with 316L claddingAlloy 20
Wear rings316L SS + Stellite hard‑facingTungsten carbide
Fasteners316 SS–

For sumps that may also collect rich amine (higher H₂S), or if chloride contamination is expected (cooling water ingress), duplex (D‑1/D‑2) is recommended. NACE MR0175 / ISO 15156 compliance is available for sour service.

Mechanical Seals – API 682 Compliance

In the VS4 configuration, the mechanical seal is located in the discharge head above grade, not submerged. However, the seal still contacts the pumped fluid via the stuffing box. Because the fluid may contain H₂S, a dual pressurised seal is strongly recommended.

Seal ArrangementAPI 682 PlanApplication
Dual pressurised (Arr. 3)Plan 53BRecommended – zero emissions, barrier fluid pressure > process, ideal for H₂S service
Tandem seal (Arr. 2)Plan 52Acceptable for low H₂S, but Plan 53B is preferred
Single seal (Arr. 1)Plan 11 / 21Not recommended for regenerator sump due to H₂S risk

Plan 53B provides a barrier fluid (typically glycol‑water or oil) pressurised above process pressure using a bladder accumulator. Seal faces: silicon carbide (SiC) / SiC. Elastomers: FKM (Viton) for up to 120°C; Aflas for higher temperatures.

Sump Design and Installation

The VS4 pump is installed vertically in a sump or pit located near the regenerator column. Key installation considerations:

  • Sump depth and column length: Must be sufficient to keep the suction strainer submerged at the lowest anticipated liquid level.

  • Minimum submergence: Per API 610 and manufacturer’s data, to prevent vortexing and air ingestion.

  • Suction strainer: Recommended to prevent debris from entering the pump.

  • Level control: The pump is typically started by a float switch or level transmitter at high sump level and stopped at low level.

  • Dry run protection: A low‑level switch or temperature sensor on the discharge head prevents damage.

Because the sump is in the regenerator area, the liquid can be hot. Insulation of the discharge head and column may be required for operator safety.

NPSH for VS4 Sump Pump

The VS4 pump has a submerged suction bell, so NPSHa is provided by the vertical height of liquid above the impeller inlet. Because the sump may have shallow depth, NPSHa can be limited. The liquid is hot and near its bubble point (dissolved gases flash easily). Select a pump with low NPSHr and ensure minimum submergence is maintained.

Minimum Flow and Intermittent Operation

Regenerator sump pumps operate intermittently – they start when the sump fills and stop when it empties. Because the pump does not run continuously against a closed valve, a minimum flow recirculation line is typically not required. However, the control system must prevent short cycling. A time delay on start‑up and a low‑level stop interlock are standard.

Applications for Regenerator Sump Pump

ApplicationFluidTypical Duty
Regenerator area drain sumpLean amine (MDEA/MEA), hot5–100 m³/h @ 20–80 m
Reboiler area spill collectionHot lean amine, steam condensate5–50 m³/h @ 15–60 m
Amine sample station drainsLean amine, sometimes rich5–30 m³/h @ 30–80 m
Seal leak collection (regenerator pumps)Amine (lean and rich)5–50 m³/h @ 20–60 m
Regenerator platform drainsAmine with water10–150 m³/h @ 20–100 m

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Bearing life (thrust bearing): L10 ≥25,000 hours

  • Critical speed: ≥120% of maximum operating speed

  • Hydrostatic test: 1.5x design pressure

  • Performance test: Water per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 (full traceability)

  • NACE MR0175 / ISO 15156 available for sour service

Why Choose Our Regenerator Sump Pump?

  • Full API 610 VS4 compliance – 11th/12th edition ISO 13709, 20‑year life

  • Vertical wet pit design – eliminates priming issues, handles low NPSHa

  • 316L stainless steel (S‑8) as standard – proven corrosion resistance in hot amine service

  • API 682 Plan 53B dual pressurised seals – zero emissions, safe H₂S containment

  • Custom column lengths – sized to your sump depth

  • Low NPSHr – reliable even with shallow sumps or hot liquids

  • Level control integration – automatic start/stop based on sump level

  • Easy maintenance – seal and bearings accessible at grade level without removing column

  • NACE MR0175 / ISO 15156 compliant options available

  • Field proven – thousands of VS4 sump pumps in amine regenerator areas worldwide

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set
Thrust bearing set1 set
Line shaft bearing set (per column section)1 set
Wear ring set1 set
Gasket / O‑ring kit (full set)1 set
Suction strainer (spare)1

Get a Quote or Engineering Support

For selection of the correct Regenerator Sump Pump for your amine regenerator area – including sump depth, fluid composition (lean amine, temperature, H₂S residual), NPSHa calculation, material selection (316L SS or duplex with NACE MR0175), API 682 seal plan (Plan 53B), level control integration, and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support gas sweetening, refinery HDS, and carbon capture projects worldwide with reliable API 610 regenerator sump pumps – safe, corrosion‑resistant collection of amine drains from the stripper area.