The Regenerator Sump Pump is a dedicated pump for collecting and transferring amine solutions – primarily lean amine – from sumps, drain pits, and collection basins located around the regenerator (stripper) column in gas sweetening plants, refinery hydrodesulfurization (HDS) units, and carbon capture (CCUS) facilities. The regenerator area collects drips from flanges, valve packing, pump seals, sample points, and occasional spillage during maintenance. These liquids are typically hot (up to 120°C), may contain residual H₂S, and are corrosive.
To ensure safe, emissions‑free, and reliable collection of these hazardous fluids, the pump is manufactured to API 610 11th/12th edition (ISO 13709) standards – guaranteeing a 20‑year design life and minimum 3‑year uninterrupted operation. The VS4 vertical suspended sump pump is the preferred configuration, with an OH2 horizontal option for dry‑pit installations.
| Pump Type | Configuration | Best Application |
|---|---|---|
| VS4 (Preferred) | Vertical suspended, wet pit, single or multistage, diffuser type | Below‑grade sumps and drain pits adjacent to regenerator; low NPSHa; fire‑code compliance; space‑constrained areas |
| OH2 (Alternative) | Overhung, centreline‑mounted, horizontal | Above‑grade small collection tanks or dry pits where sump is pumped via short suction line |
| Parameter | Range |
|---|---|
| Flow range | 5 – 400 m³/h (customisable) |
| Head range | 15 – 150 m (typical for sump evacuation) |
| Pressure rating | Up to 40 bar (580 psi) |
| Temperature range | –46°C to +260°C |
| Discharge sizes | 40 mm to 150 mm (1.5" to 6") |
| Pump column length | Custom – up to 6 meters (longer available) |
| Stages | 1 to 6 (depending on head) |
| Speed | 1,450 / 2,950 rpm |
Regenerator sump fluid is typically lean amine (MDEA, MEA, DEA) with residual H₂S, water, and possibly heat‑stable salts. The fluid is hot (80–120°C). 316L stainless steel (API 610 Class S‑8) is the minimum standard.
| Component | Material (Standard) | Upgrade Option |
|---|---|---|
| Pump column / discharge pipe | 316L stainless steel | Duplex (D‑1) |
| Diffuser casings | 316L SS (CF3M) | Duplex |
| Impellers | 316L SS | Duplex, Super Duplex |
| Shaft (line shaft) | 316 SS | 17‑4 PH, Duplex |
| Discharge head | 316L SS or carbon steel with 316L cladding | Alloy 20 |
| Wear rings | 316L SS + Stellite hard‑facing | Tungsten carbide |
| Fasteners | 316 SS | – |
For sumps that may also collect rich amine (higher H₂S), or if chloride contamination is expected (cooling water ingress), duplex (D‑1/D‑2) is recommended. NACE MR0175 / ISO 15156 compliance is available for sour service.
In the VS4 configuration, the mechanical seal is located in the discharge head above grade, not submerged. However, the seal still contacts the pumped fluid via the stuffing box. Because the fluid may contain H₂S, a dual pressurised seal is strongly recommended.
| Seal Arrangement | API 682 Plan | Application |
|---|---|---|
| Dual pressurised (Arr. 3) | Plan 53B | Recommended – zero emissions, barrier fluid pressure > process, ideal for H₂S service |
| Tandem seal (Arr. 2) | Plan 52 | Acceptable for low H₂S, but Plan 53B is preferred |
| Single seal (Arr. 1) | Plan 11 / 21 | Not recommended for regenerator sump due to H₂S risk |
Plan 53B provides a barrier fluid (typically glycol‑water or oil) pressurised above process pressure using a bladder accumulator. Seal faces: silicon carbide (SiC) / SiC. Elastomers: FKM (Viton) for up to 120°C; Aflas for higher temperatures.
The VS4 pump is installed vertically in a sump or pit located near the regenerator column. Key installation considerations:
Sump depth and column length: Must be sufficient to keep the suction strainer submerged at the lowest anticipated liquid level.
Minimum submergence: Per API 610 and manufacturer’s data, to prevent vortexing and air ingestion.
Suction strainer: Recommended to prevent debris from entering the pump.
Level control: The pump is typically started by a float switch or level transmitter at high sump level and stopped at low level.
Dry run protection: A low‑level switch or temperature sensor on the discharge head prevents damage.
Because the sump is in the regenerator area, the liquid can be hot. Insulation of the discharge head and column may be required for operator safety.
The VS4 pump has a submerged suction bell, so NPSHa is provided by the vertical height of liquid above the impeller inlet. Because the sump may have shallow depth, NPSHa can be limited. The liquid is hot and near its bubble point (dissolved gases flash easily). Select a pump with low NPSHr and ensure minimum submergence is maintained.
Regenerator sump pumps operate intermittently – they start when the sump fills and stop when it empties. Because the pump does not run continuously against a closed valve, a minimum flow recirculation line is typically not required. However, the control system must prevent short cycling. A time delay on start‑up and a low‑level stop interlock are standard.
| Application | Fluid | Typical Duty |
|---|---|---|
| Regenerator area drain sump | Lean amine (MDEA/MEA), hot | 5–100 m³/h @ 20–80 m |
| Reboiler area spill collection | Hot lean amine, steam condensate | 5–50 m³/h @ 15–60 m |
| Amine sample station drains | Lean amine, sometimes rich | 5–30 m³/h @ 30–80 m |
| Seal leak collection (regenerator pumps) | Amine (lean and rich) | 5–50 m³/h @ 20–60 m |
| Regenerator platform drains | Amine with water | 10–150 m³/h @ 20–100 m |
Design life: 20 years minimum
Bearing life (thrust bearing): L10 ≥25,000 hours
Critical speed: ≥120% of maximum operating speed
Hydrostatic test: 1.5x design pressure
Performance test: Water per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 (full traceability)
NACE MR0175 / ISO 15156 available for sour service
Full API 610 VS4 compliance – 11th/12th edition ISO 13709, 20‑year life
Vertical wet pit design – eliminates priming issues, handles low NPSHa
316L stainless steel (S‑8) as standard – proven corrosion resistance in hot amine service
API 682 Plan 53B dual pressurised seals – zero emissions, safe H₂S containment
Custom column lengths – sized to your sump depth
Low NPSHr – reliable even with shallow sumps or hot liquids
Level control integration – automatic start/stop based on sump level
Easy maintenance – seal and bearings accessible at grade level without removing column
NACE MR0175 / ISO 15156 compliant options available
Field proven – thousands of VS4 sump pumps in amine regenerator areas worldwide
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 53B ready) | 1 set |
| Thrust bearing set | 1 set |
| Line shaft bearing set (per column section) | 1 set |
| Wear ring set | 1 set |
| Gasket / O‑ring kit (full set) | 1 set |
| Suction strainer (spare) | 1 |
For selection of the correct Regenerator Sump Pump for your amine regenerator area – including sump depth, fluid composition (lean amine, temperature, H₂S residual), NPSHa calculation, material selection (316L SS or duplex with NACE MR0175), API 682 seal plan (Plan 53B), level control integration, and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
Our engineers support gas sweetening, refinery HDS, and carbon capture projects worldwide with reliable API 610 regenerator sump pumps – safe, corrosion‑resistant collection of amine drains from the stripper area.