The OH1 pump is an API 610 horizontal single-stage overhung foot-mounted centrifugal pump – the most widely used general-purpose process pump across industries. Its back pull-out design, high efficiency, low NPSH, and compact footprint make it the preferred choice for clean to slightly contaminated, low-to-medium viscosity, neutral or corrosive media. Below are the primary application scenarios.
1. Oil Refinery
Process fluid transfer – Moving crude oil, intermediate streams, and finished products between process units.
Crude oil boosting – Increasing pressure for pipeline transport to distillation units.
Distillation circulation – Reflux pumps for atmospheric and vacuum towers.
Amine / caustic service – Circulating lean/rich amine for H₂S removal; caustic wash for sweetening.
Product export – Pumping gasoline, diesel, jet fuel, naphtha to storage or loading racks.
Tank farm transfer – Moving hydrocarbons between storage tanks and process units.
Why OH1 for refinery: API 610 reliability, back pull-out for quick seal/impeller changes, wide material selection (carbon steel, 316L, duplex) for sour or corrosive services.
2. Petrochemical & Chemical
Ethylene / propylene plant auxiliaries – Cooling water circulation, quench water, process water transfer.
Solvent circulation – Pumping methanol, ethanol, acetone, MEG, and other solvents.
Neutral / corrosive media – Acids (dilute), alkalis, salts, and chemical intermediates.
Low-to-medium temperature process – Suitable for temperatures up to 250°C (425°C with cooling).
Why OH1 for chemical: Material flexibility (316L, duplex, high-chrome, PTFE gaskets), API 682 seal options for fugitive emission control, ATEX/IECEx available.
3. Power Generation
Cooling water – Circulating water for condenser cooling, auxiliary cooling, and intake water pumps.
Boiler feed (low/medium pressure) – Supplying demineralized water to deaerators or medium-pressure boilers (not ultra-high pressure – use BB3/BB4/BB5 for that).
Condensate return – Pumping condensate from hotwell or collection tanks back to deaerator.
Fire water – Emergency firefighting water supply – reliable, quick start.
Plant utility – General wash water, sump transfer, service water.
Why OH1 for power: High efficiency reduces energy cost, compact design fits in plant utility areas, 24/7 continuous duty rating.
4. Oil & Gas
Produced water – Pumping water separated from crude oil for treatment or reinjection.
Seawater injection – Lifting seawater for reservoir pressure maintenance (low to medium pressure – use BB4/BB5 for high pressure).
LPG transfer – Liquid petroleum gas – requires low NPSH and leak-tight seals (dual seals or dry gas).
MEG recovery – Monoethylene glycol circulation in hydrate inhibition systems.
Pipeline boosting – Intermediate booster stations for crude or refined products.
Why OH1 for oil & gas: Low NPSH designs for light hydrocarbons, API 682 dual seals for emission control, compact skid-mountable footprint.
5. Water & General Industry
Water supply – Municipal raw water intake, treated water distribution, booster stations.
Desalination RO feed – Low-pressure feed to reverse osmosis systems (for high-pressure RO, use BB3/BB4/BB5).
Pulp & paper – Black liquor, white liquor, process water circulation (corrosion-resistant materials).
Sugar – Juice transfer, syrup pumping, condensate return.
Mining – Dewatering, slurry water transfer, process water.
HVAC – Chilled water, hot water circulation for building heating/cooling.
Wastewater – Effluent transfer, lift station pumps.
Why OH1 for general industry: Cost-effective, easy maintenance (back pull-out), long service life, global spare parts availability.
Customization for Your Exact Duty
We provide OH1 pumps tailored to your specific operating conditions:
Flow / head – Select from our hydraulic range or custom engineer for off-design points.
Materials – Carbon steel, 304/316L, duplex, super duplex, cast iron, bronze.
Sealing – API 682 all plans (single, dual, tandem) or gland packing.
Temperature – Standard up to 250°C; with cooling jacket up to 425°C.
Impeller type – Closed (clean fluids), semi-open (slight solids), open (viscous).
Baseplate – Grouted or non-grouted (pre-engineered), API heavy-duty.
Get an Application-Specific OH1 Pump Recommendation
To help you select the right OH1 pump for your refinery, petrochemical plant, power station, or general industrial application, please send us:
Application name (e.g., "cooling water circulation" or "amine service")
Flow rate (m³/h or GPM)
Total head (m or ft)
Fluid name and temperature (°C)
Any special requirement (corrosive, solids, low NPSH, ATEX, etc.)
Our engineering team will respond within 24 hours with:
Recommended OH1 pump model (size, impeller trim, materials)
Performance curve with duty point
API 610 data sheet
CAD drawing (2D) and 3D model
Factory direct price (EXW / FOB / CIF)
Email: info@hyrig.com
We are a professional API 610 pump manufacturer (OH1, BB1, BB2, BB3, BB4, BB5 types) serving global refineries, petrochemical complexes, power utilities, oil & gas operators, and general industries. Contact us for custom-engineered OH1 pumps at factory direct wholesale pricing.