OH1 pump API 610 technical specifications. Performance: flow 5–2600 m³/h, head 10–360 m, speed 1480/2980 up to 3600 rpm, temperature -40°C to +250°C (425°C with cooling), design pressure up to 25 bar, low NPSH design with inducer optional. Construction: horizontal single-stage overhung (OH1), radial split foot-mounted casing, closed/semi-open/open impeller, single suction, forged alloy shaft meeting API 610 stiffness, oil-lubricated bearing housing, API 682 cartridge seal or gland packing, heavy-duty API baseplate (grouted/non-grouted). Materials: carbon steel, 304/316L, duplex, super duplex for casing; stainless steel/high-Cr/duplex for impeller; 4140/420/duplex forged shaft; replaceable anti-wear wear rings. Documents: API data sheet, dimensional drawing, performance curve, 3D model, material certificate, test report.

Conatct For Details
DetailReview(0)Additional

This page provides complete technical parameters for our OH1 API 610 horizontal single-stage overhung centrifugal pump. The OH1 is the most widely used general-purpose process pump with foot-mounted, radial split, end-suction design – ideal for refinery, petrochemical, chemical, power, and general industrial services.


Performance Range

ParameterValue
Flow rate5 ~ 2,600 m³/h (22 ~ 11,500 GPM)
Total head10 ~ 360 m (33 ~ 1,180 ft)
Speed1480 / 2980 rpm (50/60 Hz) – up to 3,600 rpm available
Temperature-40°C ~ +250°C (-40°F ~ +482°F) standard; up to +425°C (797°F) with cooling jacket
Design pressureUp to 25 bar (2.5 MPa / 360 psi) – higher on request
NPSHrLow NPSH hydraulic design – inducer optional for very low suction pressure

Construction Details

  • Type: Horizontal single-stage overhung (API 610 OH1 designation)

  • Casing: Radial split, foot-mounted – casing feet integrated with base for stable foundation or baseplate mounting

  • Impeller: Closed (standard for clean fluids), semi-open (for slight solids), or open (for high viscosity) – single suction

  • Shaft: Forged alloy steel, designed to meet API 610 Appendix K stiffness requirements (minimum deflection limits)

  • Bearings: Oil-lubricated bearing housing (splash or forced feed options) – heavy-duty for 24/7 continuous service

  • Seal: API 682 cartridge mechanical seal (all plans) – gland packing option available for non-critical services

  • Baseplate: Heavy-duty API design – grouted or non-grouted (pre-engineered) options

  • Back Pull-Out Design: Complete rotating assembly (impeller, shaft, bearing housing, seal) removable without disturbing suction/discharge piping – typical maintenance downtime reduced to hours


Material Options

ComponentStandard MaterialsUpgrade Options
CasingCarbon steel (WCB), 304, 316L stainless steelDuplex, super duplex, cast iron (for water)
ImpellerStainless steel (304/316L), high-chromium alloyDuplex, CD4MCu, bronze
ShaftForged 4140, 420 stainless steelDuplex, K500, 17-4PH
Wear ringsAnti-wear alloy, replaceableColmonoy-coated, Stellite, hardened 316L
GasketsSpiral wound graphite, PTFEFlexitallic, Kammprofile

Available Technical Documents (Free Request)

  • API 610 data sheet (fully filled with your operating conditions)

  • Dimensional drawing (2D CAD, PDF/DWG) – includes footprint, nozzle coordinates, baseplate details

  • Performance curve (head, efficiency, NPSHr vs flow with multiple impeller trims)

  • 3D model (STEP/IGES for plant design integration)

  • Material certificate (EN 10204 3.1 or 3.2)

  • Hydrostatic test and performance test report (per ISO 9906 Grade 2)


Key Design Features Explained

Back Pull-Out Maintenance
The OH1 pump allows removal of the entire rotating element and bearing housing without disconnecting the piping. This reduces maintenance downtime by up to 70% compared to pumps requiring full disassembly.

API 610 Shaft Stiffness
Shaft diameter is selected per API 610 Appendix K, ensuring shaft deflection at the seal face is well within allowable limits – critical for mechanical seal life.

Double Volute Option
For larger sizes (>75 mm discharge), a double volute casing balances radial thrust, extending bearing and seal life under off-peak operating conditions.

Low NPSH Design
Hydraulic optimization of the impeller inlet and casing volute provides exceptionally low NPSHr. For extremely low suction pressure, an inducer stage can be added.


Typical Industry Applications

  • Refinery: crude transfer, light hydrocarbon, reflux, product pumps

  • Petrochemical: amine, caustic, MEG, solvents, catalyst slurry

  • Chemical: acids, alkalis, salts, process water

  • Power: cooling water, fire water, boiler feed (low to medium pressure), seawater lift

  • Oil & gas: produced water, LPG, condensate, utility water

  • General industry: wash water, transfer, sump, irrigation


Get Your OH1 Pump Technical Specification Package

To request a complete documentation package with a formal quotation, please send us your operating conditions:

  • Flow rate (m³/h or GPM)

  • Total head (m or ft)

  • Fluid name and temperature (°C)

  • Any special requirement (material, seal plan, inducer, high temp, etc.)

Our engineering team will respond within 24 hours with:

  • Recommended OH1 pump model (size, trim, impeller type)

  • Performance curve PDF

  • API 610 data sheet

  • 2D CAD drawing and 3D model link

  • Material and seal recommendations

  • Factory direct price (EXW / FOB / CIF)

Email: info@hyrig.com

We are a professional API 610 pump manufacturer (OH1, BB1, BB2, BB3, BB4, BB5 types) serving global refineries, petrochemical complexes, power plants, chemical factories, and industrial facilities. Contact us for factory direct pricing and full technical support.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit