Four OH4 pump successful cases. Case 1: Refinery high temperature sump – API 610 OH4 centerline sump pump for 320°C hot oily water recovery, no thermal displacement, long stable operation. Case 2: Petrochemical high temp corrosive sump – duplex material OH4 pump handles corrosive high-temperature medium, anti-corrosion and leakage-free. Case 3: Power plant thermal sump system – multiple OH4 pump sets for high temperature condensate pit, low vibration, reliable running. Case 4: Chemical deep sump pumping – custom long sump depth OH4 pump for underground deep tank liquid recovery, efficient and low maintenance. Centerline mount eliminates thermal deformation up to 400°C. No submerged bearing ensures reliability. We provide site photos, installation drawings, and project reference data.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 OH4 vertical overhung centerline mounted sump pumps operating reliably in high temperature sump and pit services up to 400°C. Each case demonstrates the pump's key advantages – centerline mounting for thermal stability, no submerged bearing for low maintenance, and custom sump depth capability for challenging installations.


Case 1 – Refinery High Temperature Sump (Middle East)

Background: A refinery required a reliable pump for recovering hot oily water from a process unit sump at 320°C (608°F). Foot-mounted pumps experienced thermal misalignment, seal failures, and bearing distress. Conventional OH3 pumps could not handle the temperature.

OH4 Pump Solution:

  • Flow: 160 m³/h

  • Head: 35 m

  • Temperature: 320°C

  • Sump depth: 2,200 mm

  • Material: Carbon steel (high temp grade), 316L impeller

  • Features: Centerline mounting, cooling jacket on bearing housing, dry-run protection

Results:

  • No thermal displacement – centerline mount eliminated misalignment even after repeated heat cycles

  • Long stable operation – over 2.5 years without unplanned downtime

  • No submerged bearing – no failures from sand or hot water contamination

  • Maintenance reduced to annual upper bearing lubrication only

Available references: Site photo, installation drawing, thermal expansion record.


Case 2 – Petrochemical High Temp Corrosive Sump (Southeast Asia)

Background: A petrochemical plant had a sump collecting high temperature (280°C) corrosive process medium containing chlorides. Standard 316L pumps showed pitting after 6 months. The plant needed a corrosion-resistant, leak-free solution.

OH4 Pump Solution:

  • Flow: 95 m³/h

  • Head: 28 m

  • Temperature: 280°C

  • Sump depth: 1,500 mm

  • Material: Duplex stainless steel (casing, impeller, shaft)

  • Features: Centerline mount, no submerged seal, cooling jacket

Results:

  • Anti-corrosion – duplex material withstood chlorides at high temperature without pitting (2+ years)

  • Leakage-free – no submerged seal means zero leakage of hazardous chemicals

  • Reliable high temp operation – centerline mount prevented thermal distortion

  • The plant standardized on OH4 duplex pumps for all high temp corrosive sumps

Available references: Material certificate (EN 10204 3.1), installation photo, corrosion inspection report.


Case 3 – Power Plant Thermal Sump System (Asia)

Background: A thermal power plant needed multiple pumps for a high temperature condensate pit collecting hot condensate (160°C) from HRSG and turbine drains. Low vibration and automatic control were required.

OH4 Pump Solution:

  • Four OH4 pump sets (2 duty + 2 standby across two pits)

  • Flow per pump: 220 m³/h

  • Head: 22 m

  • Temperature: 160°C

  • Sump depth: 1,800 mm

  • Material: Carbon steel casing, stainless steel impeller

  • Features: Centerline mount, automatic level control system

Results:

  • Low vibration – well within API 610 limits, thanks to rigid cantilever design

  • Reliable running – continuous operation for 18 months without any pump failure

  • Automatic control – level sensors started/stops pumps as sump filled

  • No submerged bearings – pumps handled intermittent operation without issue

Available references: Control system schematic, site photos, vibration log.


Case 4 – Chemical Deep Sump Pumping (Europe)

Background: A chemical facility had an underground deep sump (3,200 mm) collecting residual liquid from tank cleaning operations. The liquid was slightly corrosive at 90°C. Access was limited to the top of the sump.

OH4 Pump Solution:

  • Flow: 55 m³/h

  • Head: 18 m

  • Temperature: 90°C

  • Sump depth: Custom 3,200 mm

  • Material: 316L stainless steel

  • Features: Extra-long cantilever shaft, strainer, dry-run protection

Results:

  • Efficient and low maintenance – custom long sump depth matched exact pit depth

  • No intermediate bearings – simple, reliable, no submerged components to fail

  • Easy top access – entire rotating assembly pulls from above, no need to enter sump

  • The facility reduced tank cleaning downtime by 40%

Available references: Custom installation drawing, site photo, maintenance log.


What You Can Request From Us for Each Case

  • Site photos and installation images

  • Installation drawings (sump pit layout, mounting details)

  • Project parameter sheet (flow, head, temperature, depth, material)

  • Operation reference data (run hours, maintenance intervals)

Why Real Project Cases Matter

Field references prove that our OH4 pumps deliver:

  • No thermal displacement at 320°C+ in refinery hot oily sump service (centerline mount advantage over OH3)

  • Corrosion resistance and leak-free performance in high temp corrosive sumps (duplex)

  • Low vibration, reliable operation in power plant condensate pits

  • Efficient deep sump recovery with custom long cantilever shafts

Get the Complete OH4 Pump Case Study Package

We can match your high temperature sump conditions to similar successful installations. Request the OH4 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery hot sump / petrochemical corrosive / power plant condensate / chemical deep sump) and we will send relevant case studies, installation drawings, and technical data within 24 hours. We also welcome inquiries for custom OH4 high temperature sump pump selection and factory direct pricing.