OH5 Pump Applications – API 610 High Speed Integral Gear Drive Pump for Refinery, Gas Plant & Chemical Process

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
OH5 pump serves high head low flow applications. Oil refinery: light naphtha, LPG and light hydrocarbon transfer, high-head low-flow process boosting, refinery auxiliary fluid pumping. Petrochemical & gas plant: ethylene, propylene and gas separation process, condensate high-speed boosting, low flow high head circulation. Power generation: high-pressure condensate return, auxiliary high head process water, small flow high lift circulating system. Chemical industry: low-flow high-head solvent delivery, light organic medium transfer, high-speed process pressurization. Industrial utility: compact skid-mounted system, limited space installation, high-speed fluid boosting service. Integral gear drive eliminates alignment, compact monoblock design, high speed up to 6000+ rpm, API 682 seals. Custom gear ratio, material (316L, duplex) and sealing solution for special high-speed working conditions.

Conatct For Details
DetailReview(0)Additional

The OH5 pump is an API 610 horizontal overhung integral gear drive pump, specifically designed for high head, low flow, high speed applications where conventional pumps are inadequate. Its unitized construction (pump + gearbox integrated) eliminates alignment issues, saves space, and delivers high-speed operation up to 6,000+ rpm. Below are the primary application scenarios.


1. Oil Refinery

  • Light naphtha, LPG and light hydrocarbon transfer – Pumping volatile, low-viscosity hydrocarbons at high pressure with low flow rates.

  • High-head low-flow process boosting – Increasing pressure of small process streams between units.

  • Refinery auxiliary fluid pumping – Chemical injection, additive dosing, and small-volume catalyst feed.

Why OH5 for refinery: High speed achieves required head with a single stage. API 682 mechanical seals (dual or dry gas) handle light hydrocarbon leakage risks. Compact design fits in crowded refinery skids.


2. Petrochemical & Gas Plant

  • Ethylene, propylene and gas separation process – Pumping light olefins and refrigeration duty loops at low flow, high head.

  • Condensate high-speed boosting – Raising pressure of hydrocarbon condensate from gas processing trains.

  • Low flow high head circulation – Circulation loops in fractionation columns or heat exchanger networks.

Why OH5 for gas plant: Integral gear drive handles high speeds without external alignment. Low NPSH design for light ends. Explosion-proof and ATEX options available.


3. Power Generation

  • High-pressure condensate return – Pumping hot condensate back to deaerator or boiler feed system at low flow, high head.

  • Auxiliary high head process water – Small-volume high-pressure water for spray, cooling, or wash systems.

  • Small flow high lift circulating system – Closed loop circulation with limited flow but high pressure requirement.

Why OH5 for power: High efficiency at low flow reduces energy cost. Compact footprint for plant auxiliary skids.


4. Chemical Industry

  • Low-flow high-head solvent delivery – Pumping organic solvents at precise high pressure for reactor feeding.

  • Light organic medium transfer – Moving alcohols, ketones, aromatics at low flow rates against high system pressure.

  • High-speed process pressurization – Generating high pressure for membrane separation or small-scale processes.

Why OH5 for chemical: Corrosion-resistant materials (316L, duplex) available. API 682 dual seals for fugitive emission control.


5. Industrial Utility

  • Compact skid-mounted system – Plants with limited footprint require integrated pump + gearbox units.

  • Limited space installation – Existing facilities where horizontal pump + motor + gearbox cannot fit.

  • High-speed fluid boosting service – Any application requiring moderate pressure rise at low flow with high reliability.

Why OH5 for utility: One-piece unit reduces piping complexity and installation time. Factory alignment eliminates field adjustments.


Custom Solutions for Special High-Speed Working Conditions

  • Custom gear ratio – Tailored to your speed requirement (3,000–12,000+ rpm)

  • Material upgrades – Carbon steel, 316L, duplex, super duplex, high-strength alloy

  • Sealing solutions – API 682 Plan 11, 21, 23, 52, 53, 54; dry gas seals for LPG/light ends

  • Impeller design – Closed or semi-open; inducer for low NPSH

  • Motor options – Explosion-proof, VFD-ready, high-speed motor


Get an Application-Specific OH5 Pump Recommendation

Send us your operating conditions:

  • Application name (e.g., "LPG transfer" or "condensate boosting")

  • Flow rate (m³/h or GPM)

  • Total head (m or ft)

  • Fluid name and temperature (°C)

  • Any special requirement (low NPSH, seal plan, ATEX, etc.)

Our engineering team will respond within 24 hours with:

  • Recommended OH5 pump model (gear ratio, impeller trim)

  • High-speed performance curve with duty point

  • API 610 data sheet

  • CAD drawing (2D) and 3D model

  • Material and seal recommendations

  • Factory direct price (EXW / FOB / CIF)

Email: info@hyrig.com

We are a professional API 610 pump manufacturer (OH1, OH2, OH3, OH4, OH5, BB1, BB2, BB3, BB4, BB5, VS types) serving global refineries, petrochemical plants, gas plants, chemical facilities, and power utilities. Contact us for custom-engineered OH5 integral gear drive pumps at factory direct wholesale pricing.