Four OH5 pump successful cases. Case 1: Refinery light hydrocarbon transfer – API 610 OH5 integral gear drive pump for LPG and naphtha transfer, high speed stable operation, small footprint. Case 2: Gas plant condensate boosting – high-speed OH5 pump for condensate pressurization, low flow high head perfectly matched process requirement. Case 3: Petrochemical process skid – compact OH5 pump integrated on process skid, reliable long-term running, easy maintenance. Case 4: Power plant high head auxiliary system – OH5 high speed pump for high-head low-flow circulating water, high efficiency and stable performance. We provide skid layout drawing, site reference and performance data for each installation.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 OH5 horizontal overhung integral gear drive pumps operating reliably in high speed, low flow, high head applications. Each case demonstrates the pump's compact footprint, factory-aligned unitized construction, and ability to achieve high head without multiple stages or external gearboxes.


Case 1 – Refinery Light Hydrocarbon Transfer (Middle East)

Background: A refinery needed a reliable pump for LPG (propane/butane) and light naphtha transfer from storage spheres to process units. Flow was low, but head requirement was high due to system backpressure. Conventional OH1 pumps at 2,980 rpm could not achieve the required head without adding a gearbox.

OH5 Pump Solution:

  • Flow: 35 m³/h

  • Head: 380 m

  • Speed: 5,800 rpm (gear increased)

  • Material: 316L stainless steel casing and impeller

  • Seal: API 682 Plan 53B dual mechanical seal (for LPG leak prevention)

Results:

  • High speed stable operation – achieved required head with single stage

  • Small footprint – unitized OH5 replaced pump + external gearbox + baseplate, saving 40% skid space

  • Factory alignment – no field alignment issues, reduced installation time

  • Zero leakage – dual seal with barrier fluid contained LPG safely

Available references: Skid layout drawing, site photo, seal performance log.


Case 2 – Gas Plant Condensate Boosting (Southeast Asia)

Background: A gas processing plant required a condensate boosting pump to raise pressure of hydrocarbon condensate (C3+) from the deethanizer bottom to the next fractionator. Flow was low (35–50 m³/h), but required head was high (320 m). The existing multistage pump was oversized and suffered from seal failures.

OH5 Pump Solution:

  • Flow: 45 m³/h

  • Head: 320 m

  • Speed: 5,200 rpm

  • Material: Carbon steel casing, 17-4PH impeller

  • Seal: API 682 Plan 21 with cooled flush

Results:

  • Low flow high head perfectly matched process requirement – single stage OH5 replaced 6-stage BB3 pump

  • Higher efficiency at low flow – reduced energy consumption by 15%

  • Maintenance simplified – back pull-out design without disturbing piping

  • No seal failures – API 682 Plan 21 provided adequate cooling

Available references: Performance curve comparison, installation photo, efficiency report.


Case 3 – Petrochemical Process Skid (Europe)

Background: An engineering company was designing a modular process skid for a petrochemical plant. Space was extremely limited, and the skid required a compact high head pump for chemical injection service (methanol at 25 m³/h, 280 m head).

OH5 Pump Solution:

  • Flow: 25 m³/h

  • Head: 280 m

  • Speed: 6,200 rpm

  • Material: 316L stainless steel

  • Seal: API 682 Plan 52 dual seal

  • Integration: Direct skid-mounted, motor coupled via flexible spacer coupling

Results:

  • Compact OH5 pump integrated on process skid – fit within tight footprint (1.2m x 0.8m)

  • Reliable long-term running – over 18 months continuous operation without failure

  • Easy maintenance – back pull-out design allowed seal replacement without removing pump from skid

  • The skid supplier standardized on OH5 pumps for all high head low flow services

Available references: Skid layout drawing (PDF/DWG), site photo, maintenance log.


Case 4 – Power Plant High Head Auxiliary System (Asia)

Background: A thermal power plant needed a small-flow, high-head circulating pump for an auxiliary cooling loop (high-pressure spray water). Flow was only 12 m³/h, but head required was 450 m. Standard pumps could not meet the duty without multistage designs.

OH5 Pump Solution:

  • Flow: 12 m³/h

  • Head: 450 m

  • Speed: 7,200 rpm

  • Material: Duplex stainless steel (for corrosion resistance)

  • Seal: API 682 Plan 23 jacketed seal

Results:

  • High efficiency (68% at low flow) – better than multistage alternatives

  • Stable performance – vibration levels below API 610 limits

  • Minimal maintenance – only annual bearing and seal inspection

  • Compact design – easily fit into existing auxiliary skid without modification

Available references: Skid layout drawing, performance test report, site photo.


What You Can Request From Us for Each Case

  • Skid layout drawing (PDF/DWG) – showing pump footprint and connections

  • Site photos and installation images

  • Project parameter sheet (flow, head, speed, material, seal)

  • Performance data (efficiency, vibration, power consumption)

  • User reference contact (with prior permission)

Why Real Project Cases Matter

Field references prove that our OH5 pumps deliver:

  • High speed, stable operation for light hydrocarbon transfer (LPG, naphtha)

  • Perfect low flow high head matching for gas plant condensate boosting

  • Compact, reliable integration on petrochemical process skids

  • High efficiency, stable performance for power plant auxiliary high head systems

Get the Complete OH5 Pump Case Study Package

We can match your high speed, low flow, high head conditions to similar successful installations. Request the OH5 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery / gas plant / petrochemical skid / power plant) and we will send relevant case studies, skid layout drawings, and performance data within 24 hours. We also welcome inquiries for custom OH5 integral gear drive pump selection and factory direct pricing.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit