The TEDA XQ140/12A Hydraulic Power Tong comes with a complete operation & maintenance manual. Covers pre-start checks, remote-controlled make/break procedures, daily/weekly/monthly maintenance, and a fault troubleshooting table. Features emergency stop, IP54 protection, and easy gripper replacement. Extends service life to 8‑10 years with proper care. Safety rules included. For manual or spare parts, contact info@hyrig.com.

Conatct For Details
DetailReview(0)Additional

Preface

This manual is dedicated to the XQ140/12A Hydraulic Power Tong, intended for field operators, maintenance personnel, and technical training. It follows equipment design standards and oilfield safety regulations, detailing operating procedures, maintenance schedules, fault diagnosis, and safety instructions. The goal is to help users operate correctly, reduce failures, extend service life, and ensure safe and efficient operations. All procedures have been factory-verified. Do not modify equipment parameters or violate operating rules.


I. Operating Procedures (Preparation → Operation → Shutdown)

(A) Pre-Start Check (5 minutes)

Environment check:

  • No obstacles, no flammable/explosive materials. Ground level (on offshore platforms, confirm equipment is securely fixed).

  • Ambient temperature within -20°C to +60°C – take temperature control measures if outside range.

Equipment inspection:

  • Appearance: No deformation, damage, or oil leaks. Jaw opens/closes freely, no sticking.

  • Connections: Hydraulic hoses firmly attached. Quick couplers tight, no aging. Electrical cables intact.

  • Lubrication: Check oil level in jaw and rotating parts. Top up with ISO VG46 anti-wear hydraulic oil if low.

  • Control device: Remote panel buttons responsive. Display shows no fault codes. Batteries fully charged (for wireless remote).

Parameter setting:
Based on pipe diameter, preset torque via control panel (reference: small pipe 20–80 kN·m, large pipe 100–140 kN·m). Confirm rotation direction (clockwise for make-up, counter-clockwise for break-out).

(B) Standard Operating Procedure (remote control preferred – tubing make-up example)

StepAction
1. Power onPress main power switch. Hydraulic pressure rises to 12MPa. Wait for display to show “Ready”.
2. Position pipePlace tubing at work position. Align jaw opening with pipe center.
3. Grip pipePress “Open/Close” button on remote. Jaw closes to grip pipe. Confirm secure grip (no slip). Release button.
4. Make-upPress “Make-up” button. Tong rotates to preset torque. Auto-stop when torque reached. Display shows “Make-up complete”.
5. Release jawPress “Open/Close” button. Jaw opens. Move tong or pipe for next joint.

Break-out procedure: Switch rotation direction to “Counter-clockwise”. Press “Break-out” button. Tong first loosens, then unscrews until pipe separates. Other steps same as above.

(C) Post-Operation Shutdown

  1. Stop: Press main power switch. Close hydraulic system. Release residual pressure (press relief valve until pressure reads 0).

  2. Clean: Wipe oil and dirt from surfaces. Clean debris from jaw gripper slots.

  3. Inspect: Check for oil leaks or loose parts. Record operating hours and pipe count. Fill equipment log.

  4. Store: Coil hydraulic hoses neatly. Place remote in tool box. For long-term storage, drain hydraulic oil, cover with dust cover, store in dry ventilated area.

(D) Special Operation Notes

  • Emergency stop: In case of abnormality (pipe deformation, unusual noise, oil leak), immediately press red “Emergency Stop” button on remote or main unit. Power and hydraulic supply cut. Investigate fault before restart.

  • Pipe size change: Stop tong first. Adjust jaw opening and re‑preset torque. Do not switch during operation.

  • Manual operation: If remote fails, use local control panel. Same steps. Ensure operator stays at safe distance (≥1.5m).


II. Daily & Periodic Maintenance

(A) Daily Maintenance (before and after each operation – 5 minutes)

ItemActionStandardCorrection
CleaningWipe surfaces, jaw, hose fittingsNo oil, no debrisWipe with diesel then dry. Do not wash electrical parts with water.
Leak checkCheck hydraulic system, fittings, sealsNo drip or seepageTighten fittings for minor seepage; replace seals for major leak.
LubricationCheck oil level in jaw and rotating bearingsAt or above sight glass midlineTop up with ISO VG46 anti-wear hydraulic oil.
Remote/panelButton response, displayQuick response, no garbled displayClean buttons. Replace remote batteries.

(B) Weekly Maintenance (after operation – 30 minutes)

  • Remove jaw grippers, clean debris and wear particles. Check gripper tooth wear – replace if wear >1mm.

  • Inspect hydraulic hoses for cracks or bulges – replace immediately (recommended replacement every 12 months).

  • Tighten bolts on main body and mounting base to prevent vibration damage.

  • Test emergency stop function – ensure immediate power cut.

  • Check hydraulic oil contamination – if oil is dark or has particles, filter or replace oil.

(C) Monthly Maintenance (by qualified personnel – 1 hour)

  • Replace hydraulic filter element (model HF6501). Clean sediment from tank bottom.

  • Check jaw rotating bearing clearance – if >0.5mm, adjust or replace bearing.

  • Calibrate torque accuracy with torque tester – if deviation exceeds ±5%, contact factory.

  • Inspect FKM seals for aging – replace any hardened or deformed seals.

  • Remove rust from welded areas and structural parts. Reapply anti-corrosion coating if rust found.

(D) Annual Maintenance (factory service or professional team)

  • Fully disassemble tong. Inspect core components (gears, hydraulic pump, motor) – replace if worn.

  • Replace all hydraulic oil and lubricating oil. Clean tank and hoses.

  • Perform full anti-corrosion treatment (sandblasting + electrostatic powder coating).

  • Fully calibrate equipment parameters (torque, speed, pressure) to factory standards.

  • Issue maintenance report with component replacement records and next maintenance recommendations.


III. Common Fault Troubleshooting (Table Format)

FaultPossible CauseDiagnosis StepsSolutionFactory support needed?
Unit won’t start, display blank1. No power 2. Blown fuse 3. Panel failure1. Check plug/switch 2. Open control box, check fuse (10A) 3. Test panel power1. Connect power 2. Replace with same rating fuse 3. Replace panelYes for #3
Low hydraulic pressure, insufficient torque1. Low oil level 2. Pump failure 3. Pressure regulator valve stuck1. Check tank level 2. Listen for abnormal pump noise 3. Test pressure with gauge1. Top up oil 2. Replace pump filter or pump 3. Calibrate or replace valveYes for #2,3
Jaw slips, cannot grip pipe1. Worn gripper inserts 2. Pipe too oily 3. Jaw opening incorrect1. Check gripper teeth 2. Clean pipe surface 3. Verify jaw opening matches pipe OD1. Replace grippers 2. Clean pipe with diesel 3. Adjust jaw openingNo
Unusual noise during operation1. Bearing dry 2. Gear wear 3. Pipe off‑center1. Check bearing oil 2. Stop, rotate jaw manually, listen 3. Check pipe alignment1. Add oil 2. Replace gear (contact factory) 3. Re‑position pipeYes for #2
Oil leak at hose fitting1. Loose fitting 2. Seal老化 3. Hose damaged1. Tighten fitting nut 2. Inspect seal for deformation 3. Check hose surface1. Tighten until no seepage 2. Replace seal 3. Replace hoseNo
Remote no response, local works1. Remote battery dead 2. Signal interference 3. Remote module fault1. Replace battery 2. Move away from high‑power devices, shorten distance 3. Check module wiring1. Replace battery 2. Adjust position 3. Repair/replace moduleYes for #3

IV. Safety Instructions (Strictly Follow)

  • Personnel protection: Hard hat, steel‑toe boots, protective gloves required. No loose clothing or jewelry – risk of entanglement.

  • Safe distance: Non‑operators must stay ≥1.5m away. Do not stand under or near rotating jaw.

  • Do not operate when:

    • Equipment fault not resolved

    • Thunderstorm or wind speed > Force 6 (onshore) / > Force 8 (offshore platform)

    • Hydraulic oil temperature exceeds 60°C (without cooler)

    • Poor lighting or unclear visibility

  • Modifications prohibited: Do not modify structure, change hydraulic pressure, or use non‑genuine parts – warranty voided and safety at risk.

  • Emergency response: If tong jams or pipe breaks, immediately stop power, evacuate surrounding personnel, contact technical support. Do not force restart.

  • Training required: Operators must be trained and approved by factory. Untrained personnel are prohibited from operating.


V. Maintenance Tools & Consumables List

Required Tools

  1. Torque wrench (0–200 kN·m)

  2. Hex key set

  3. Pipe wrench (300mm)

  4. Hydraulic oil filter machine

  5. Seal installation tool

  6. Rags, diesel (for cleaning)

  7. Lubrication oil can

Recommended Spare Consumables

ItemQuantity recommended
ISO VG46 anti-wear hydraulic oil (5L pail)1‑2 pails
Special lubricating oil (1L bottle)1 bottle
Gripper inserts (for 2⅜″–5½″ pipe, each size)1‑2 sets per size
FKM seal kit1 kit
Hydraulic hose (5m length)2‑3 hoses
Fuse (10A)10 pcs
Remote battery (CR2032)5 pcs

Need the full TEDA power tong range or genuine spare parts?
We supply all TEDA models and all related accessories.

Contact us today:
info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit