This manual is dedicated to the XQ140/12A Hydraulic Power Tong, intended for field operators, maintenance personnel, and technical training. It follows equipment design standards and oilfield safety regulations, detailing operating procedures, maintenance schedules, fault diagnosis, and safety instructions. The goal is to help users operate correctly, reduce failures, extend service life, and ensure safe and efficient operations. All procedures have been factory-verified. Do not modify equipment parameters or violate operating rules.
Environment check:
No obstacles, no flammable/explosive materials. Ground level (on offshore platforms, confirm equipment is securely fixed).
Ambient temperature within -20°C to +60°C – take temperature control measures if outside range.
Equipment inspection:
Appearance: No deformation, damage, or oil leaks. Jaw opens/closes freely, no sticking.
Connections: Hydraulic hoses firmly attached. Quick couplers tight, no aging. Electrical cables intact.
Lubrication: Check oil level in jaw and rotating parts. Top up with ISO VG46 anti-wear hydraulic oil if low.
Control device: Remote panel buttons responsive. Display shows no fault codes. Batteries fully charged (for wireless remote).
Parameter setting:
Based on pipe diameter, preset torque via control panel (reference: small pipe 20–80 kN·m, large pipe 100–140 kN·m). Confirm rotation direction (clockwise for make-up, counter-clockwise for break-out).
| Step | Action |
|---|---|
| 1. Power on | Press main power switch. Hydraulic pressure rises to 12MPa. Wait for display to show “Ready”. |
| 2. Position pipe | Place tubing at work position. Align jaw opening with pipe center. |
| 3. Grip pipe | Press “Open/Close” button on remote. Jaw closes to grip pipe. Confirm secure grip (no slip). Release button. |
| 4. Make-up | Press “Make-up” button. Tong rotates to preset torque. Auto-stop when torque reached. Display shows “Make-up complete”. |
| 5. Release jaw | Press “Open/Close” button. Jaw opens. Move tong or pipe for next joint. |
Break-out procedure: Switch rotation direction to “Counter-clockwise”. Press “Break-out” button. Tong first loosens, then unscrews until pipe separates. Other steps same as above.
Stop: Press main power switch. Close hydraulic system. Release residual pressure (press relief valve until pressure reads 0).
Clean: Wipe oil and dirt from surfaces. Clean debris from jaw gripper slots.
Inspect: Check for oil leaks or loose parts. Record operating hours and pipe count. Fill equipment log.
Store: Coil hydraulic hoses neatly. Place remote in tool box. For long-term storage, drain hydraulic oil, cover with dust cover, store in dry ventilated area.
Emergency stop: In case of abnormality (pipe deformation, unusual noise, oil leak), immediately press red “Emergency Stop” button on remote or main unit. Power and hydraulic supply cut. Investigate fault before restart.
Pipe size change: Stop tong first. Adjust jaw opening and re‑preset torque. Do not switch during operation.
Manual operation: If remote fails, use local control panel. Same steps. Ensure operator stays at safe distance (≥1.5m).
| Item | Action | Standard | Correction |
|---|---|---|---|
| Cleaning | Wipe surfaces, jaw, hose fittings | No oil, no debris | Wipe with diesel then dry. Do not wash electrical parts with water. |
| Leak check | Check hydraulic system, fittings, seals | No drip or seepage | Tighten fittings for minor seepage; replace seals for major leak. |
| Lubrication | Check oil level in jaw and rotating bearings | At or above sight glass midline | Top up with ISO VG46 anti-wear hydraulic oil. |
| Remote/panel | Button response, display | Quick response, no garbled display | Clean buttons. Replace remote batteries. |
Remove jaw grippers, clean debris and wear particles. Check gripper tooth wear – replace if wear >1mm.
Inspect hydraulic hoses for cracks or bulges – replace immediately (recommended replacement every 12 months).
Tighten bolts on main body and mounting base to prevent vibration damage.
Test emergency stop function – ensure immediate power cut.
Check hydraulic oil contamination – if oil is dark or has particles, filter or replace oil.
Replace hydraulic filter element (model HF6501). Clean sediment from tank bottom.
Check jaw rotating bearing clearance – if >0.5mm, adjust or replace bearing.
Calibrate torque accuracy with torque tester – if deviation exceeds ±5%, contact factory.
Inspect FKM seals for aging – replace any hardened or deformed seals.
Remove rust from welded areas and structural parts. Reapply anti-corrosion coating if rust found.
Fully disassemble tong. Inspect core components (gears, hydraulic pump, motor) – replace if worn.
Replace all hydraulic oil and lubricating oil. Clean tank and hoses.
Perform full anti-corrosion treatment (sandblasting + electrostatic powder coating).
Fully calibrate equipment parameters (torque, speed, pressure) to factory standards.
Issue maintenance report with component replacement records and next maintenance recommendations.
| Fault | Possible Cause | Diagnosis Steps | Solution | Factory support needed? |
|---|---|---|---|---|
| Unit won’t start, display blank | 1. No power 2. Blown fuse 3. Panel failure | 1. Check plug/switch 2. Open control box, check fuse (10A) 3. Test panel power | 1. Connect power 2. Replace with same rating fuse 3. Replace panel | Yes for #3 |
| Low hydraulic pressure, insufficient torque | 1. Low oil level 2. Pump failure 3. Pressure regulator valve stuck | 1. Check tank level 2. Listen for abnormal pump noise 3. Test pressure with gauge | 1. Top up oil 2. Replace pump filter or pump 3. Calibrate or replace valve | Yes for #2,3 |
| Jaw slips, cannot grip pipe | 1. Worn gripper inserts 2. Pipe too oily 3. Jaw opening incorrect | 1. Check gripper teeth 2. Clean pipe surface 3. Verify jaw opening matches pipe OD | 1. Replace grippers 2. Clean pipe with diesel 3. Adjust jaw opening | No |
| Unusual noise during operation | 1. Bearing dry 2. Gear wear 3. Pipe off‑center | 1. Check bearing oil 2. Stop, rotate jaw manually, listen 3. Check pipe alignment | 1. Add oil 2. Replace gear (contact factory) 3. Re‑position pipe | Yes for #2 |
| Oil leak at hose fitting | 1. Loose fitting 2. Seal老化 3. Hose damaged | 1. Tighten fitting nut 2. Inspect seal for deformation 3. Check hose surface | 1. Tighten until no seepage 2. Replace seal 3. Replace hose | No |
| Remote no response, local works | 1. Remote battery dead 2. Signal interference 3. Remote module fault | 1. Replace battery 2. Move away from high‑power devices, shorten distance 3. Check module wiring | 1. Replace battery 2. Adjust position 3. Repair/replace module | Yes for #3 |
Personnel protection: Hard hat, steel‑toe boots, protective gloves required. No loose clothing or jewelry – risk of entanglement.
Safe distance: Non‑operators must stay ≥1.5m away. Do not stand under or near rotating jaw.
Do not operate when:
Equipment fault not resolved
Thunderstorm or wind speed > Force 6 (onshore) / > Force 8 (offshore platform)
Hydraulic oil temperature exceeds 60°C (without cooler)
Poor lighting or unclear visibility
Modifications prohibited: Do not modify structure, change hydraulic pressure, or use non‑genuine parts – warranty voided and safety at risk.
Emergency response: If tong jams or pipe breaks, immediately stop power, evacuate surrounding personnel, contact technical support. Do not force restart.
Training required: Operators must be trained and approved by factory. Untrained personnel are prohibited from operating.
Torque wrench (0–200 kN·m)
Hex key set
Pipe wrench (300mm)
Hydraulic oil filter machine
Seal installation tool
Rags, diesel (for cleaning)
Lubrication oil can
| Item | Quantity recommended |
|---|---|
| ISO VG46 anti-wear hydraulic oil (5L pail) | 1‑2 pails |
| Special lubricating oil (1L bottle) | 1 bottle |
| Gripper inserts (for 2⅜″–5½″ pipe, each size) | 1‑2 sets per size |
| FKM seal kit | 1 kit |
| Hydraulic hose (5m length) | 2‑3 hoses |
| Fuse (10A) | 10 pcs |
| Remote battery (CR2032) | 5 pcs |
Need the full TEDA power tong range or genuine spare parts?
We supply all TEDA models and all related accessories.
Contact us today:
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.