Standard horizontal pumps struggle with low Net Positive Suction Head (NPSH) – they cavitate when the liquid pressure at the impeller eye falls below vapour pressure. Vertical barrel pumps solve this by submerging the first‑stage impeller inside a cylindrical outer barrel (can) that is either buried or installed in a tank/sump. The liquid level above the pump provides positive suction head, eliminating cavitation even for boiling liquids (e.g., LNG) or high‑temperature boiler feed water.
The pump consists of two concentric casings:
Outer barrel (can) – A pressure‑retaining vessel (forged steel or fabricated) that surrounds the inner pump assembly. It is sealed at the top by a discharge head.
Inner pump assembly (cartridge) – Contains the multistage diffuser and impeller stack, shaft, and radial bearings. It can be withdrawn upward for maintenance without removing the outer barrel.
This double‑casing construction allows the outer barrel to withstand high pressures (up to 350 bar) while the inner assembly is optimised for hydraulic performance.
Liquid enters through the suction bell at the bottom of the outer barrel, fully submerged.
First‑stage impeller accelerates the liquid into the first diffuser, which converts velocity to pressure.
Flow passes through successive stages (typically 4 to 20) – each impeller adds more pressure.
Total head = head per stage × number of stages (minus small losses). For example, 10 stages × 100 m/stage = 1,000 m head.
Liquid exits through the discharge head at the top, routed to the process.
Because the suction bell is submerged below the minimum operating liquid level, the pump sees positive NPSHa equal to the vertical height of liquid above the first‑stage impeller. This allows the pump to handle:
Boiler feed water from a deaerator operating at 3‑5 m head – no cavitation.
LNG at near‑boiling point – the submerged suction prevents flashing.
Seawater lift from offshore platform caissons – pump can be set 10‑20 m below sea level.
| Parameter | Typical range |
|---|---|
| Flow | Up to 3,000 m³/h (13,200 GPM) |
| Head | Up to 3,500 m (11,500 ft) |
| Pressure rating | Up to 350 bar (5,000 psi) |
| Temperature range | –196°C to +250°C (LNG to hot water) |
| Number of stages | 2 – 20 |
| Speed | Up to 6,000 rpm |
| Design life | 20 years minimum |