This page presents verified field cases of our API 610 VS1 vertical submerged multistage pumps operating reliably inside tanks, sumps, and vessels. Each case demonstrates the pump's ultra-low NPSH capability, high head performance, and maintenance-free submerged design.
Case 1 – Refinery Process Tank Pumping (Middle East)
Background: A refinery needed to pump hot intermediate product from a large process tank. The liquid level was low relative to the pump centerline, and available NPSH was insufficient for conventional horizontal pumps, causing cavitation and seal failures.
VS1 Pump Solution:
Flow: 280 m³/h
Head: 480 m
Temperature: 220°C
Column length: 4,500 mm
Material: Carbon steel casing, 316L impellers
Stages: 6
Results:
Low NPSH – fully submerged design eliminated cavitation completely
Stable high head output – multistage delivered required pressure smoothly
No suction piping – reduced leak paths and installation cost
Continuous operation for over 2 years without pump-related downtime
Available references: Tank installation layout drawing, site photo, NPSH calculation sheet.
Case 2 – Petrochemical Corrosive Tank Service (Southeast Asia)
Background: A petrochemical plant stored aggressive organic solvents in a large tank. The required transfer head was 520 m, but the liquid level was low. Standard stainless steel pumps showed corrosion, and submerged bearings failed frequently.
VS1 Pump Solution:
Flow: 150 m³/h
Head: 520 m
Temperature: 65°C
Column length: 3,800 mm
Material: Duplex stainless steel (casing, impeller, shaft)
Stages: 7
Bearings: PTFE liquid-lubricated
Results:
Long service life – duplex resisted pitting and crevice corrosion for 3+ years
No leakage – no submerged seal; top discharge seal only
Low maintenance – internal liquid-lubricated bearings required no external oil
The plant standardized duplex VS1 pumps for all corrosive tank services
Available references: Material certificate (EN 10204 3.1), installation photo, corrosion inspection report.
Case 3 – Power Plant Condensate Tank (Asia)
Background: A combined cycle power plant experienced cavitation and performance loss in their condensate transfer system. The condensate hotwell had a low liquid level, and the existing horizontal pump could not maintain stable operation during load changes.
VS1 Pump Solution:
Flow: 210 m³/h
Head: 380 m
Temperature: 85°C
Column length: custom 3,200 mm
Material: Carbon steel casing, stainless steel impellers
Stages: 5
Results:
24h continuous stable operation – no cavitation even at minimum hotwell level
Custom submerged length matched exact tank depth
No foundation required – pump hung from tank nozzle, saving civil work
Energy efficient – multistage design eliminated need for booster pump
Available references: Tank installation drawing, site photo, DCS pressure log.
Case 4 – Chemical Deep Sump High Lift (Europe)
Background: A chemical facility had a deep underground sump collecting waste acid from multiple process drains. The sump depth was 6 meters, and the required discharge head to the treatment plant was 280 m. Horizontal pumps could not suction lift from that depth.
VS1 Pump Solution:
Flow: 85 m³/h
Head: 280 m
Temperature: 40°C
Column length: 6,200 mm
Material: 316L stainless steel
Stages: 4
Results:
Solved low liquid level high head delivery – VS1 lifted from 6 m depth to 280 m head
Reduced civil construction cost – no separate pump house or suction pit required
Simple installation – pump inserted directly into sump cover flange
Low maintenance – annual pull-out inspection, bearings still in good condition
Available references: Sump layout drawing, site photo, head versus flow test data.
What You Can Request From Us for Each Case
Tank installation layout drawings (2D CAD)
Site photos and installation images
Project parameter sheet (flow, head, stages, column length, material)
Performance test data and NPSH calculations
Why Real Project Cases Matter
Field references prove that our VS1 pumps deliver:
No cavitation in low NPSH refinery tank services (fully submerged advantage)
Long life and leak-free operation in corrosive petrochemical tanks (duplex materials)
24/7 stable condensate boosting in power plants (custom submerged length)
Low liquid level high head solution for chemical deep sumps (multistage + submerged)
Get the Complete VS1 Pump Case Study Package
We can match your tank depth, liquid level, and head requirement to similar successful installations. Request the VS1 pump project case PDF or ask for references in your specific industry.
Email: info@hyrig.com
Please specify your industry (refinery / petrochemical / power / chemical) and we will send relevant case studies, tank installation drawings, and technical data within 24 hours. We also welcome inquiries for custom VS1 vertical submerged multistage pump selection and factory direct pricing.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.