VS5 Pump Project Cases – API 610 Vertical Multistage Long Shaft Sump Pump for Refinery, Power, Chemical & Mining

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Four VS5 pump successful cases. Case 1: Refinery deep sump recovery – custom long column VS5 pump in deep oily sump, high head stable delivery, low maintenance frequency. Case 2: Power plant condensate sump – multistage VS5 pump for condensate high-head lifting, 24h continuous operation, high efficiency. Case 3: Chemical plant corrosive deep pit – 316L material VS5 vertical pump, anti-corrosion and reliable for underground deep pit medium transfer. Case 4: Mining deep water drainage – long shaft VS5 pump matched mine deep well condition, solves high-lift long-distance water delivery. Top motor design – no submerged motor. Multistage up to 1000 m head, custom column length. We provide installation layout drawing, site photos, and project reference parameters.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 VS5 vertical multistage long shaft sump pumps operating reliably in deep sump, high head, and challenging environments. Each case demonstrates the pump's top motor design (no submerged motor), custom long column capability, multistage high head performance, and low maintenance in refineries, power plants, chemical facilities, and mining operations.


Case 1 – Refinery Deep Sump Recovery (Middle East)

Background: A refinery had a deep oily water sump (5.5 m depth) collecting runoff from process units and tank farm drains. The required discharge head was 220 m to send the oily water to treatment. Submersible pumps failed frequently due to motor flooding and seal leaks. Horizontal pumps could not suction lift from that depth.

VS5 Pump Solution:

  • Flow: 120 m³/h

  • Head: 220 m

  • Column length: 5,800 mm

  • Stages: 5

  • Material: Carbon steel column, 316L impellers

  • Motor: Top mounted, dry, above grade

Results:

  • High head stable delivery – multistage achieved required 220 m lift consistently

  • Low maintenance frequency – after 2 years, only routine bearing inspection required (no motor failures)

  • No submerged motor – eliminated electrical and flooding risks

  • Easy access – motor and pull-out shaft serviced from grade level, no confined space entry

Available references: Installation layout drawing, site photo, maintenance log.


Case 2 – Power Plant Condensate Sump (Southeast Asia)

Background: A combined cycle power plant required a pump to lift hot condensate (85°C) from a deep hotwell (4.2 m depth) to the deaerator at 180 m head. Available NPSH was very low due to condensate near boiling point.

VS5 Pump Solution:

  • Flow: 160 m³/h

  • Head: 180 m

  • Column length: 4,500 mm

  • Stages: 4

  • Material: Cast iron column, bronze fitted impellers

  • Bearing: Water-lubricated line shaft bearings

Results:

  • 24h continuous operation – pump ran for over 18 months without failure

  • High efficiency (83%) – lower energy cost compared to previous submersible units

  • Low NPSH – submerged first stage eliminated cavitation on hot condensate

  • Simple maintenance – annual pull-out inspection completed in 4 hours

Available references: Installation drawing, site photo, efficiency comparison chart.


Case 3 – Chemical Plant Corrosive Deep Pit (China)

Background: A chemical plant had an underground deep pit (6 m depth) collecting slightly corrosive acidic waste. The required lift was 150 m to the neutralization tank. Standard 316L submersible pumps corroded at the motor housing seals.

VS5 Pump Solution:

  • Flow: 85 m³/h

  • Head: 150 m

  • Column length: 6,200 mm

  • Stages: 3

  • Material: 316L stainless steel (column, impeller, shaft, hardware)

  • Motor: Top mounted, dry, explosion-proof (ATEX)

Results:

  • Anti-corrosion – 316L material withstood acidic environment for 2.5 years with no pitting

  • Reliable for underground deep pit – top motor stayed in clean, dry area above ground

  • No seal leakage at motor end – motor not submerged, eliminating that failure mode

  • Low maintenance – annual bearing check; no corrosion on wetted parts

Available references: Material certificate (EN 10204 3.1), site photo, corrosion inspection report.


Case 4 – Mining Deep Water Drainage (South America)

Background: An open pit mine needed to dewater from a deep well (8 m below grade) with total required head of 420 m to discharge water to the surface treatment plant. Submersible pumps had limited lift and were difficult to retrieve for maintenance.

VS5 Pump Solution:

  • Flow: 200 m³/h

  • Head: 420 m

  • Column length: 8,200 mm (custom)

  • Stages: 9

  • Material: High chrome alloy impellers (for abrasive mine water)

  • Shaft: High strength alloy steel

Results:

  • Matched mine deep well condition – custom long column reached 8 m depth

  • Solved high-lift long-distance water delivery – 420 m head achieved with single pump

  • Top motor accessible – no need to pull motor from deep pit for routine service

  • Wear-resistant – high chrome impellers showed minimal erosion after 1 year in abrasive water

Available references: Installation layout drawing, site photo, wear inspection report.


What You Can Request From Us for Each Case

  • Installation layout drawings (2D CAD, column and pit details)

  • Site photos and pump assembly images

  • Project parameter sheet (flow, head, stages, column length, material)

  • Operating data (vibration, bearing temperature, performance)

Why Real Project Cases Matter

Field references prove that our VS5 pumps deliver:

  • High head, stable delivery, low maintenance in refinery deep oily sumps

  • 24/7 high efficiency, low NPSH performance in power plant condensate lifting

  • Corrosion resistance and reliability in chemical deep pits (316L, top motor)

  • High-lift, long-distance mine dewatering with custom long columns

Get the Complete VS5 Pump Case Study Package

We can match your deep sump depth and high head requirement to similar successful installations. Request the VS5 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery / power / chemical / mining) and we will send relevant case studies, installation drawings, and technical data within 24 hours. We also welcome inquiries for custom VS5 vertical long shaft multistage pump selection and factory direct pricing.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit