The VS7 pump is an API 610 vertical can‑type pump with a built‑in submersible motor, specially designed for volatile, low NPSH, flammable, and zero‑leakage process duties. Unlike conventional vertical pumps (VS1–VS6) that rely on external mechanical seals, the VS7 has no shaft penetrating the pressure boundary. The motor is fully enclosed inside a sealed can, eliminating the primary leak path. This makes the VS7 the ultimate solution for LPG, light hydrocarbons, ethylene, propylene, condensate, and other low‑boiling‑point liquids where zero emissions and ultra‑low NPSH are critical. Below we compare the VS7 against VS2 and VS5 pump types.
Core Advantages of VS7 Pump
Submersible Motor Inside Can → No External Shaft Seal, Zero Leakage
The motor and pump are completely enclosed within a pressure‑tight can. There is no dynamic seal where a shaft passes through the can wall – the primary source of leakage in conventional pumps. Zero emissions, zero product loss, zero fire hazard.
Pressure Tight Can Structure → Perfect for Volatile / Low Boiling Point Media
The can is a full pressure vessel rated up to 140 bar. It safely contains volatile liquids, even near their boiling point. No vapor release, no cavitation, no seal failure.
Ultra Low NPSH Design → Solve Cavitation of LPG and Light Hydrocarbon
The can is flooded from the suction vessel, keeping the pump fully submerged. Static liquid head provides positive suction pressure, allowing operation with available NPSH as low as 0.5 meters. Conventional pumps would cavitate under these conditions.
Integrated Cartridge → Easy Pull‑Out Maintenance
The entire motor‑pump assembly is a single cartridge. To service, remove the can cover and lift the cartridge vertically. The can body and piping stay in place – no pipe disconnection required.
Explosion‑Proof Standard → Suitable for Hazardous Area ATEX / IECEx
Motors are certified explosion‑proof (Ex d) for Class I, Division 1 or Zone 1/Zone 2 hazardous areas. Standard for petrochemical and gas plant use.
VS7 vs VS2 (Vertical Can‑Type with Top Mounted Motor)
| Feature | VS7 (Submersible Motor in Can) | VS2 (Top Mounted Motor) |
|---|---|---|
| Shaft seal | No external seal | Mechanical seal at top of can |
| Leakage risk | Zero | Possible seal wear/leakage |
| Volatile liquid suitability | Excellent (fully sealed) | Moderate (seal must be perfect) |
| NPSH performance | Ultra low (flooded can) | Ultra low (flooded can) |
| Maintenance | Pull cartridge | Pull cartridge (plus seal replacement) |
| Best for | LPG, light hydrocarbons, zero‑emission | General low NPSH, less volatile |
Verdict: Choose VS7 for absolute zero leakage when handling LPG, light ends, or any volatile/flamable liquid where emissions cannot be tolerated. Choose VS2 for low NPSH service with less stringent leakage requirements (e.g., hot condensate, water).
VS7 vs VS5 (Vertical Long Shaft Sump Pump with Top Motor)
| Feature | VS7 | VS5 |
|---|---|---|
| Motor location | Inside can (submersible) | Top deck (dry) |
| Shaft seal | None (sealed can) | Line shaft bearings + top mechanical seal |
| Leakage path | None | Potential seal & column flange leaks |
| Volatile liquid | Excellent | Poor (leakage risk along shaft) |
| NPSH | Ultra low (flooded can) | Moderate (submerged first stage) |
| Best for | Volatile, flammable, LPG | Deep sump, non‑volatile, high head |
Verdict: VS7 is the only choice for volatile liquids (LPG, propane, ethylene). VS5 is suitable for deep sump pumping of water, oily water, or other non‑volatile fluids where some leakage risk is acceptable.
VS7 vs Other VS Types (VS1, VS3, VS4, VS6)
Conventional VS pumps (VS1–VS6) all rely on an external mechanical seal somewhere between the pump and the atmosphere. For volatile, low‑boiling‑point liquids, these seals are a constant failure risk. The VS7 completely eliminates the seal, offering the ultimate in safety and environmental compliance.
Best Suitable Conditions for VS7 Pump
LPG, propane, butane, light hydrocarbons (C2–C5)
Ethylene, propylene, and other monomers
Low NPSH service (<2 m available)
Zero‑leakage requirement (VOC emissions control, safety)
Hazardous area (ATEX Zone 1/2, Class I Div 1)
High pressure can‑type pressurization (up to 140 bar)
Get a VS7 Pump vs VS2 / VS5 Comparison for Your Duty
Our engineering team provides free pump selection advisory. Send us your duty point:
Flow rate (m³/h or GPM)
Total head (m or ft)
Fluid (LPG, propane, ethylene, etc.) and temperature
Available NPSH (or specify “low NPSH”)
Any special requirement (zero leakage, ATEX, can pressure rating)
We will reply within 24 hours with:
Recommended pump type (VS7, VS2, or VS5)
Side‑by‑side comparison for your specific duty
Performance curve and API 610 data sheet
Can installation drawing (2D CAD) and 3D model
Factory direct price (EXW / FOB / CIF)
Email: info@hyrig.com
We are a professional API 610 pump manufacturer (OH1–OH6, BB1–BB5, VS1–VS7 types) serving global refineries, petrochemical plants, gas plants, and chemical facilities. Contact us for custom‑engineered VS7 vertical can‑type submersible motor pumps – the zero‑leakage, ultra‑low NPSH solution for volatile and flammable liquids – at factory direct wholesale pricing.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.