Four VS7 pump successful cases. Case 1: Refinery LPG pumping – API 610 VS7 can‑type pump for LPG transfer, ultra low NPSH no cavitation, zero leakage safe operation. Case 2: Gas plant condensate service – duplex material VS7 pump for volatile condensate medium, sealed can design avoids vaporization and leakage. Case 3: Petrochemical low boiling point medium – integrated VS7 cartridge pump installed on tank top, compact layout, long‑term maintenance‑free running. Case 4: Hazardous area sealed process – explosion‑proof VS7 pump matched petrochemical hazardous area standard, safe and stable 24/7 operation. Submersible motor inside sealed can – no external shaft seal, zero leakage. Ultra‑low NPSH handles LPG and light hydrocarbons. We provide can layout drawing, site reference, and performance test data.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 VS7 vertical can‑type submersible motor pumps operating in volatile, low NPSH, and zero‑leakage applications. Each case demonstrates the pump’s ability to handle LPG, light hydrocarbons, condensate, and other low‑boiling‑point liquids with absolute safety, no shaft seal leakage, and ultra‑low NPSH performance.


Case 1 – Refinery LPG Pumping (Middle East)

Background: A refinery needed a reliable pump for LPG (propane/butane) transfer from storage spheres to a gasification unit. The available NPSH was less than 1.5 meters, and any leakage of flammable LPG was absolutely unacceptable due to fire risk and environmental regulations.

VS7 Pump Solution:

  • Flow: 65 m³/h

  • Head: 210 m

  • Pressure rating: 30 bar

  • Material: Carbon steel can, 316L impeller

  • Motor: Ex d explosion‑proof, inside can

  • Seal: No external seal – sealed can design

Results:

  • Ultra low NPSH – operated reliably with 1.2 m available NPSH, no cavitation

  • Zero leakage safe operation – no product loss, no vapor release, no fire hazard

  • Stable performance – discharge pressure maintained within ±1.5% over 2 years

  • Easy maintenance – cartridge pulled for inspection without removing can from piping

Available references: Can layout drawing, site photo, NPSH calculation sheet.


Case 2 – Gas Plant Condensate Service (Southeast Asia)

Background: A natural gas processing plant required a pump for volatile condensate (rich in C3+ hydrocarbons) from a low‑pressure separator. The liquid was near boiling point, and conventional mechanical seal pumps failed due to vaporization at the seal face.

VS7 Pump Solution:

  • Flow: 95 m³/h

  • Head: 320 m

  • Temperature: 45°C (near boiling point of light ends)

  • Material: Duplex stainless steel (can, impeller, internal parts)

  • Motor: Explosion‑proof, can‑type submersible

Results:

  • Sealed can design avoids vaporization and leakage – no seal face to fail

  • Handled volatile condensate reliably – no cavitation despite low NPSH

  • Zero emissions – met strict environmental permit requirements

  • Long service life – duplex material resisted sour gas corrosion

Available references: Material certificate (EN 10204 3.1), site photo, seal‑less operation log.


Case 3 – Petrochemical Low Boiling Point Medium (Asia)

Background: A petrochemical plant needed a pump for low‑boiling‑point solvent (pentane) transfer from a storage tank. Space was limited, and the pump had to be mounted on the tank top. Zero leakage was required due to flammability.

VS7 Pump Solution:

  • Flow: 35 m³/h

  • Head: 150 m

  • Can length: 2,800 mm (tank top‑mounted)

  • Material: 316L stainless steel

  • Installation: Integrated cartridge pump on tank top nozzle

Results:

  • Compact layout – tank top installation saved ground space, no external foundation

  • Long‑term maintenance‑free running – over 2 years without any service intervention

  • No shaft seal – eliminated leakage risk at tank top (fire safety)

  • Quick pull‑out – annual inspection completed in 3 hours

Available references: Can layout drawing, tank top installation photo, maintenance record.


Case 4 – Hazardous Area Sealed Process (Europe)

Background: A chemical plant in an ATEX Zone 1 area needed a pump for a flammable, low‑vapor‑pressure solvent (methyl tert‑butyl ether, MTBE). The process required 24/7 continuous pumping with zero emissions and absolute safety.

VS7 Pump Solution:

  • Flow: 55 m³/h

  • Head: 280 m

  • Temperature: 60°C

  • Material: 316L can and impeller

  • Motor: ATEX/IECEx certified Ex d IIC, Zone 1

  • Seal: None (fully sealed can)

Results:

  • Explosion‑proof VS7 pump matched petrochemical hazardous area standard – certified for Zone 1

  • Safe and stable 24/7 operation – no unplanned downtime over 18 months

  • Zero leakage – no VOC emissions, no safety incidents

  • Silent, vibration‑free – can design dampened noise and vibration

Available references: ATEX certificate, site photo, safety inspection report.


What You Can Request From Us for Each Case

  • Can layout drawing (2D CAD – tank or vessel installation)

  • Site photos and pump assembly images

  • Project parameter sheet (flow, head, pressure, material, motor rating)

  • Performance test data (NPSHr, efficiency, vibration)

Why Real Project Cases Matter

Field references prove that our VS7 pumps deliver:

  • Ultra low NPSH, zero leakage for refinery LPG service

  • Reliable, sealed operation for gas plant volatile condensate (duplex materials)

  • Compact, maintenance‑free tank top installation for low boiling point media

  • ATEX‑certified, 24/7 safe operation in hazardous areas

Get the Complete VS7 Pump Case Study Package

We can match your volatile, low NPSH, or zero‑leakage conditions to similar successful installations. Request the VS7 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery / gas plant / petrochemical / hazardous area) and we will send relevant case studies, can layout drawings, and technical data within 24 hours. We also welcome inquiries for custom VS7 can‑type submersible motor pump selection and factory direct pricing.