The XQ89/3C hydraulic power tong is widely used in oil well workover operations for tubing make-up and break-out. To help you maintain peak performance and minimize downtime, this guide provides a systematic approach to fault diagnosis, repair, and prevention.
| Parameter | Value |
|---|---|
| Tubing range | 2⅜", 2⅞", 3½" |
| High gear speed (@80 L/min) | 100 r/min |
| Low gear speed (@80 L/min) | 30 r/min |
| High gear rated torque (@10 MPa) | 1.1 kN·m |
| Low gear rated torque (@10 MPa) | 3.0 kN·m |
| Low gear max torque (@12.5 MPa) | 4.0 kN·m |
| Rated pressure | 10 MPa |
| Max pressure | 12.5 MPa |
| Rated flow | 80 L/min |
| Weight (master + backup) | 122 kg + 58 kg |
Safety first – Always disconnect hydraulic power and wait for the tong to stop completely before inspection or repair. Never touch moving parts while the tong is running.
Logical sequence – Start with external and simple checks (hoses, worn parts, operation errors) before moving to internal components.
Genuine parts only – Use only original TEDA replacement parts. Non‑standard parts may cause repeated failures.
Professional support – For hydraulic motor, main control valve, or transmission assembly faults, contact the manufacturer’s after‑sales service.
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Debris in jaw grooves; Worn jaws (tooth height worn >1mm) or wrong jaw type; Insufficient braking torque (spring fatigue); Tong not leveled; Hydraulic pressure below 10 MPa | Inspect jaw surface for debris or wear; Check jaw type matches tubing size; Check brake spring (3C1-33) for deformation/looseness; Verify leveling with gauge; Read pressure gauge (4) | Clean jaw grooves with diesel/kerosene; Replace with correct genuine jaws; Tighten spring bolt or replace spring; Adjust leveling screw (3C1-89(1)); Increase supply pressure to 10 MPa | Clean jaws after each job; Inspect jaws every 300 hours; Check brake spring every 6 months; Re‑level after each installation; Calibrate pressure gauge regularly |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Reset knobs (3C1-54/3C2-2) not correctly set; Retaining pins (3C1-93/3C2-5) not locked; Return spring (3C1-108) deformed/broken; Internal jamming (roller shaft rust, foreign objects) | Check knob arrow points to correct direction (make-up/break-out); Verify retaining pin fully engaged in knob slot; Manually rotate jaw to feel resistance; Remove cover and inspect return spring | Rotate reset knob 180° then back to locked position; Replace broken/deformed return spring (3C1-108); Clean roller shaft (3C1-106) and jaw carrier with diesel, apply grease; Disassemble jaw assembly (Fig.8) if heavily jammed | Reset knobs properly after each job; Inspect return springs every 800 hours; Regularly grease rotating parts |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Backup hydraulic hoses reversed (pressure/return swapped); Backup cylinder leak (O-ring failure); Backup jaw carrier rotates opposite to master; Low backup hydraulic pressure | Compare hose connections (3C2-40) with master tong; Check cylinder (3C2-19A) for oil seepage; Manually operate backup and observe rotation direction; Read backup pressure gauge if equipped | Swap the two backup hoses (3C2-40) to correct direction; Replace damaged O-rings (3C2-53/3C2-54), tighten cylinder bolts; Adjust backup gear mesh to synchronize with master; Increase backup pressure to rated value (same as master) | Mark hoses during installation to avoid reversal; Check hoses and seals every 600 hours; Perform no‑load test after installation |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Weak shift spring (3C1-133); Worn or bent shift fork (3C1-129); Debris or worn gear teeth; Shifting attempted at high speed | Remove shift handle assembly (3C1-136) and check spring; Inspect shift fork for bending or tooth wear; Open gearbox cover and inspect gear mesh; Ask operator about shifting conditions | Replace shift spring, adjust preload; Replace bent/worn shift fork (3C1-129); Clean gearbox interior with diesel, replace gear oil; Replace damaged gears (refer to Fig.11) if severe wear; Always shift at low speed or when stopped | Shift gently; Inspect shift mechanism every 1000 hours; Replace gearbox oil annually |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Contaminated oil; Blocked hoses or filter; Cooler malfunction (dirty radiator, fan not running); Prolonged over‑pressure operation (>12.5 MPa); Wrong hydraulic oil grade | Check oil color (dark brown indicates contamination); Inspect hoses for kinks/flattening, check filter; See if radiator surface is clogged; Verify pressure gauge readings during operation; Confirm oil grade against specification | Replace with new anti‑wear hydraulic oil (ISO VG 46), clean tank and filter; Straighten hoses, replace filter element; Clean radiator, check fan, replace if needed; Keep operating pressure ≤12.5 MPa; Use recommended oil grade | Change oil every 500 hours, clean filter regularly; Check hose routing before each job; Clean radiator periodically; Monitor oil temperature – stop if >60°C |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Hydraulic power source not turned on; Main control valve (3C1-110) clogged or stuck; Hydraulic motor failure (internal leakage, bearing seized); Emergency stop button not reset; Loose electrical/hydraulic connections | Check power switch and oil supply valve; Operate handle – feel for sticking; Inspect motor (3C1-44) for leaks or abnormal noise; Check emergency stop button; Inspect all connections | Turn on power/oil supply; Remove main valve, clean spool (3C1-112) with diesel, reinstall; Contact service for motor repair/replacement; Press emergency stop then reset; Tighten loose fittings, replace old seals | Pre‑operation check of power source, switches, connections; Clean main valve regularly; Overhaul motor annually |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Low hydraulic oil level; Poor gear engagement (wear or foreign objects); Low motor torque output; Gear not fully engaged (half‑shift) | Check oil level in tank; Open gearbox cover, inspect gear mesh and foreign objects; Measure motor inlet/outlet pressure; Re‑shift to ensure full engagement with “click” sound | Top up oil to specified level, check for leaks; Remove foreign objects, replace worn gears; Repair motor (seals or complete unit); Adjust shift mechanism clearance for reliable lock | Check oil level regularly; Keep debris away from gearbox; Always shift fully – never half‑engaged |
| Possible Causes | Diagnostic Steps | Corrective Actions | Preventive Measures |
|---|---|---|---|
| Loose fitting, aged seal; Hose damaged (cracked or abraded); Damaged threads on fitting | Locate leak – fitting or hose body?; Check threads for wear/stripping; Inspect seal washer (e.g., copper washer 3C1-143) for deformation | Tighten fitting, replace aged seal; Replace damaged hose (use genuine part 3C2-40); Repair or replace fitting with damaged threads | Inspect fittings every 100 hours; Protect hoses from crushing/abrasion; Replace seals every 6 months |
Basic – Screwdrivers (flat/cross), hex keys (M6–M12), combo wrenches (10–24mm), pliers, torque wrench
Special – Jaw removal tool, hydraulic hose fitting wrench, gearbox cover tool
Testing – Pressure gauge (0–20 MPa), spirit level, tape measure, oil contamination meter (optional)
Cleaning – Diesel, kerosene, rags, brushes
Sealing – O‑rings (36×3.5, 26×2.4, etc.), copper washers, sealant
Lubrication – High‑temp grease, anti‑wear hydraulic oil ISO VG 46
Wear parts – Jaws (dies), brake spring, return spring, seal washers (stock common sizes)
To assist future troubleshooting and factory support, maintain a Fault Log with the following information:
| Field | Description |
|---|---|
| Date & time | When the fault occurred |
| Operating conditions | Tubing size, working pressure, ambient temperature |
| Fault description | Detailed symptom (e.g., “Jaw slipping – tubing rotated during make‑up”) |
| Diagnosis process | Steps taken to identify cause |
| Parts replaced | Part numbers and quantities |
| Corrective action | What was done to fix |
| Result | Verification (e.g., “Normal gripping after 30 hours of operation”) |
| Personnel | Operator and technician signatures |
This log helps optimize maintenance schedules and provides precise data when contacting after‑sales service.
For technical support, genuine parts, or on‑site service, please contact:
info@hyrig.com
We offer fast response and professional troubleshooting assistance.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.