Amine Regeneration Reflux Pump – API 610 OH2 / BB3 for Gas Sweetening Reflux Service

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 amine regeneration reflux pump (reflux pump for amine regenerator column). Single-stage OH2 or multistage BB3 configurations. Returns condensed reflux (water, amine, hydrocarbons) from regenerator overhead condenser to top of regeneration column. Flow up to 500 m³/h, head up to 260 m (OH2) or 1,500 m (BB3). Materials: 316L SS (S-8), duplex. API 682 Plan 53B dual seals for H₂S service.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Amine Regeneration Reflux Pump is a critical component in the amine sweetening process, specifically located in the regeneration section (stripper / regenerator column). After rich amine is stripped of acid gases (H₂S and CO₂) in the regenerator, the overhead vapour passes through a condenser where water, residual amine, and condensed hydrocarbons are liquefied. The reflux pump returns this liquid stream – known as reflux – back to the top of the regenerator column to control column temperature, maintain proper vapour-liquid equilibrium, and recover amine.

All pumps in this series are fully engineered and manufactured to API 610 11th/12th edition (ISO 13709) standards, ensuring minimum 3-year uninterrupted operation and a 20-year design life. The reflux service is relatively low head compared to lean amine charge pumps, but the fluid often contains H₂S, CO₂, and hydrocarbons, requiring corrosion-resistant materials and tight sealing to prevent fugitive emissions.

Pump Configurations for Amine Regeneration Reflux

The Amine Regeneration Reflux Pump is most commonly supplied as an OH2 (overhung, centerline-mounted, single-stage) pump due to the moderate head requirement (typically 60–150 m). In some high-head cases (e.g., tall regenerator columns with significant elevation), a BB3 (axial split, multistage) pump may be selected.

Pump TypeConfigurationBest Reflux Pump Application
OH2 (Preferred)Overhung, centerline-mounted, single-stageModerate head (≤260 m), moderate flow (10–400 m³/h); standard for most amine regenerator reflux services
BB3Axially split, single casing, multistage, between bearingsHigher head (260–500 m) where regenerator pressure or elevation demands additional head

OH2 – Standard Reflux Pump

The OH2 configuration is the industry standard for amine regeneration reflux duty. Characteristics include:

  • Single-stage overhung impeller with centerline mounting

  • Back pull-out design – rotating assembly removable without disconnecting piping

  • API 610 bearing housing with oil bath lubrication; L10 bearing life ≥25,000 hours

  • Flow range: 10 – 400 m³/h (higher flows possible with larger frame sizes)

  • Head range: 30 – 260 m

  • Temperature range: –45°C to +200°C

  • Standard materials: 316L stainless steel (S-8) for corrosion resistance to amine, H₂S, and CO₂

The reflux pump typically takes suction from the regenerator overhead accumulator (reflux drum) and discharges back to the top of the column, overcoming column pressure and static head.

BB3 – For High-Head or Elevated Columns

For very tall regenerator columns or applications with significant pressure differential, a BB3 multistage pump provides:

  • Horizontally split single casing, between bearings

  • Opposed (back-to-back) impellers for axial thrust self-balancing

  • Head up to 1,500 m (though reflux rarely exceeds 500 m)

  • Same material selection as OH2 (S-8 standard)

Key Technical Specifications

ParameterOH2 (Standard)BB3 (Optional)
Flow range10 – 400 m³/h20 – 500 m³/h
Head range30 – 260 m60 – 500 m (higher if required)
Pressure ratingUp to 64 barUp to 150 bar
Temperature–45°C to +200°C–45°C to +200°C
Speed1,450 / 2,950 rpm1,450 / 2,950 rpm
NPSHrOptimized (inducer optional)Optimized first stage

Reflux Service – Process Description

In an amine regeneration system:

  1. Rich amine (loaded with H₂S/CO₂) enters the regenerator column near the top.

  2. Steam from the reboiler strips acid gases as the amine flows downward.

  3. Overhead vapour (acid gases + water vapour + amine vapour + hydrocarbons) exits the column.

  4. The vapour passes through the regenerator overhead condenser, condensing water, amine, and hydrocarbons.

  5. The condensed liquid collects in the reflux accumulator / reflux drum.

  6. The Amine Regeneration Reflux Pump returns this liquid to the top of the regenerator column as reflux.

The reflux serves three purposes:

  • Controls column temperature by returning cooled liquid

  • Maintains vapour-liquid equilibrium for efficient stripping

  • Recovers amine that would otherwise be lost with the acid gas stream

Materials – API 610 Table H

The reflux fluid contains water, condensed amine (typically MDEA, MEA, or DEA), residual H₂S and CO₂, and sometimes light hydrocarbons. Corrosion can occur – especially in the presence of heat-stable salts or oxygen ingress.

ComponentRecommended API 610 ClassMaterialRemarks
CasingS-8316L stainless steel (CF3M)Resistance to amine corrosion and pitting from chlorides/salts
ImpellerS-8316L stainless steelSame as casing
ShaftA-8 / C-6316 SS or 4140 with coatingCorrosion-resistant or hardened
Wear ringsS-8 with hard facing316L SS + StelliteExtend service life
Gaskets—Spiral wound (graphite filled)For flange sealing

Carbon steel (C-6) is NOT recommended for amine regeneration reflux because:

  • The fluid contains water and H₂S, which can cause severe corrosion in carbon steel

  • Condensed amine can be aggressive at elevated temperatures

  • 316L SS (S-8) is the proven, reliable choice

For reflux circuits that also contain high chlorides (e.g., from cooling water leakage into the overhead condenser), duplex (D-1/D-2) may be specified.

Mechanical Seals – API 682 Compliance

The reflux stream contains H₂S, which is toxic and hazardous. Fugitive emissions are strictly regulated. Therefore, a dual pressurised mechanical seal arrangement is strongly recommended.

Seal ArrangementAPI 682 PlanSuitability for Reflux Pump
Single seal (Arr. 1)Plan 11 / 21NOT recommended – H₂S risk
Tandem seal (Arr. 2)Plan 52Acceptable – buffer fluid collects leakage
Dual pressurized (Arr. 3)Plan 53B (bladder accumulator)Recommended – barrier fluid pressure > process, zero emissions

Plan 53B with bladder accumulator provides:

  • Barrier fluid pressurised above process pressure using a nitrogen-charged bladder

  • No nitrogen entrainment into process (unlike Plan 53A with pressurised reservoir)

  • Visual level indicator and low pressure alarm

  • Absolute containment of H₂S-containing reflux fluid

Seal face materials: Silicon carbide (SiC) or tungsten carbide. Secondary seals: FKM (Viton) or Aflas for higher temperatures.

NPSH Considerations for Reflux Pump

The reflux pump suction is typically taken from an atmospheric or low-pressure overhead accumulator / reflux drum. NPSHa is usually limited to 2–5 meters (drum elevation relative to pump centerline).

To ensure reliable operation without cavitation:

  • Select a pump with low NPSHr (optimized first-stage impeller design)

  • Consider an inducer option if NPSHa is marginal (<1.5 m above NPSHr)

  • Ensure NPSHa ≥ NPSHr + 1.0 m per API 610 recommendation

  • The fluid is near its bubble point (contains dissolved gases), so do NOT assume subcooling in NPSHa calculation

Minimum Flow Protection

During start-up, shutdown, or low-demand periods, the reflux pump must be protected from operating below Minimum Continuous Stable Flow (MCSF). A minimum flow recirculation line (with orifice or automated recirculation valve) returns flow to the reflux drum to maintain safe pump operation.

Applications for Amine Regeneration Reflux Pump

ApplicationProcessTypical Flow / Head
Natural gas sweeteningMDEA/MEA reflux after H₂S/CO₂ stripping20–300 m³/h @ 60–150 m
Refinery hydrodesulfurization (HDS) amine unitReflux of lean amine regenerator30–350 m³/h @ 80–180 m
Claus tail gas treatment (TGTU)Amine regenerator reflux10–150 m³/h @ 50–120 m
CCUS (carbon capture)Amine-based CO₂ capture regeneration40–400 m³/h @ 60–200 m
Syngas / ammonia plantAmine wash unit regenerator reflux10–200 m³/h @ 40–120 m

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Continuous operation: Minimum 3 years uninterrupted service

  • Bearing life: L10 ≥25,000 hours (API 610 mandatory)

  • Critical speed: First lateral critical speed ≥120% of maximum operating speed

  • Centerline mounting (OH2): Accommodates thermal expansion in hot reflux service (up to 150°C)

  • Hydrostatic testing: Casing tested at 1.5x design pressure

  • Performance testing: Water performance test per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 (full traceability for all pressure-containing and wetted parts)

Why Choose Our Amine Regeneration Reflux Pump?

  • Full API 610 11th/12th edition compliance (ISO 13709) – 20-year life, 3-year continuous run

  • OH2 configuration – the industry standard for regenerator reflux duty; compact, easy to maintain

  • 316L stainless steel (S-8) wetted parts – proven corrosion resistance in hot amine/H₂S/water service

  • API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S containment

  • Low NPSHr design – reliable operation even with limited suction head from reflux drum

  • Centerline mounting – maintains alignment during thermal cycling (reflux at 60–150°C)

  • Back pull-out design – rotor and seal replacement without disturbing piping

  • Minimum flow recirculation provisions – protects pump during turndown

  • Broad hydraulic coverage – flows 10–400 m³/h, heads 30–260 m, covering virtually all amine regenerator reflux applications

  • Field proven – thousands of API 610 OH2 pumps in amine reflux service worldwide

Recommended Spare Parts

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set per pump
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller)1 set
Gasket / O-ring kit1 set per pump
Inducer (if fitted)1 set

Get a Quote or Engineering Support

For detailed selection of the correct Amine Regeneration Reflux Pump for your gas sweetening or refinery amine unit – including reflux flow and head calculation, NPSHa verification from overhead accumulator, material selection (316L SS or duplex for high-chloride service), API 682 seal plan (Plan 53B with bladder accumulator for H₂S service), and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support natural gas sweetening, refinery HDS, and carbon capture projects worldwide with reliable API 610 amine regeneration reflux pumps – ensuring safe, efficient regenerator operation.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit