The Amine Regeneration Reflux Pump is a critical component in the amine sweetening process, specifically located in the regeneration section (stripper / regenerator column). After rich amine is stripped of acid gases (H₂S and CO₂) in the regenerator, the overhead vapour passes through a condenser where water, residual amine, and condensed hydrocarbons are liquefied. The reflux pump returns this liquid stream – known as reflux – back to the top of the regenerator column to control column temperature, maintain proper vapour-liquid equilibrium, and recover amine.
All pumps in this series are fully engineered and manufactured to API 610 11th/12th edition (ISO 13709) standards, ensuring minimum 3-year uninterrupted operation and a 20-year design life. The reflux service is relatively low head compared to lean amine charge pumps, but the fluid often contains H₂S, CO₂, and hydrocarbons, requiring corrosion-resistant materials and tight sealing to prevent fugitive emissions.
The Amine Regeneration Reflux Pump is most commonly supplied as an OH2 (overhung, centerline-mounted, single-stage) pump due to the moderate head requirement (typically 60–150 m). In some high-head cases (e.g., tall regenerator columns with significant elevation), a BB3 (axial split, multistage) pump may be selected.
| Pump Type | Configuration | Best Reflux Pump Application |
|---|---|---|
| OH2 (Preferred) | Overhung, centerline-mounted, single-stage | Moderate head (≤260 m), moderate flow (10–400 m³/h); standard for most amine regenerator reflux services |
| BB3 | Axially split, single casing, multistage, between bearings | Higher head (260–500 m) where regenerator pressure or elevation demands additional head |
The OH2 configuration is the industry standard for amine regeneration reflux duty. Characteristics include:
Single-stage overhung impeller with centerline mounting
Back pull-out design – rotating assembly removable without disconnecting piping
API 610 bearing housing with oil bath lubrication; L10 bearing life ≥25,000 hours
Flow range: 10 – 400 m³/h (higher flows possible with larger frame sizes)
Head range: 30 – 260 m
Temperature range: –45°C to +200°C
Standard materials: 316L stainless steel (S-8) for corrosion resistance to amine, H₂S, and CO₂
The reflux pump typically takes suction from the regenerator overhead accumulator (reflux drum) and discharges back to the top of the column, overcoming column pressure and static head.
For very tall regenerator columns or applications with significant pressure differential, a BB3 multistage pump provides:
Horizontally split single casing, between bearings
Opposed (back-to-back) impellers for axial thrust self-balancing
Head up to 1,500 m (though reflux rarely exceeds 500 m)
Same material selection as OH2 (S-8 standard)
| Parameter | OH2 (Standard) | BB3 (Optional) |
|---|---|---|
| Flow range | 10 – 400 m³/h | 20 – 500 m³/h |
| Head range | 30 – 260 m | 60 – 500 m (higher if required) |
| Pressure rating | Up to 64 bar | Up to 150 bar |
| Temperature | –45°C to +200°C | –45°C to +200°C |
| Speed | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm |
| NPSHr | Optimized (inducer optional) | Optimized first stage |
In an amine regeneration system:
Rich amine (loaded with H₂S/CO₂) enters the regenerator column near the top.
Steam from the reboiler strips acid gases as the amine flows downward.
Overhead vapour (acid gases + water vapour + amine vapour + hydrocarbons) exits the column.
The vapour passes through the regenerator overhead condenser, condensing water, amine, and hydrocarbons.
The condensed liquid collects in the reflux accumulator / reflux drum.
The Amine Regeneration Reflux Pump returns this liquid to the top of the regenerator column as reflux.
The reflux serves three purposes:
Controls column temperature by returning cooled liquid
Maintains vapour-liquid equilibrium for efficient stripping
Recovers amine that would otherwise be lost with the acid gas stream
The reflux fluid contains water, condensed amine (typically MDEA, MEA, or DEA), residual H₂S and CO₂, and sometimes light hydrocarbons. Corrosion can occur – especially in the presence of heat-stable salts or oxygen ingress.
| Component | Recommended API 610 Class | Material | Remarks |
|---|---|---|---|
| Casing | S-8 | 316L stainless steel (CF3M) | Resistance to amine corrosion and pitting from chlorides/salts |
| Impeller | S-8 | 316L stainless steel | Same as casing |
| Shaft | A-8 / C-6 | 316 SS or 4140 with coating | Corrosion-resistant or hardened |
| Wear rings | S-8 with hard facing | 316L SS + Stellite | Extend service life |
| Gaskets | — | Spiral wound (graphite filled) | For flange sealing |
Carbon steel (C-6) is NOT recommended for amine regeneration reflux because:
The fluid contains water and H₂S, which can cause severe corrosion in carbon steel
Condensed amine can be aggressive at elevated temperatures
316L SS (S-8) is the proven, reliable choice
For reflux circuits that also contain high chlorides (e.g., from cooling water leakage into the overhead condenser), duplex (D-1/D-2) may be specified.
The reflux stream contains H₂S, which is toxic and hazardous. Fugitive emissions are strictly regulated. Therefore, a dual pressurised mechanical seal arrangement is strongly recommended.
| Seal Arrangement | API 682 Plan | Suitability for Reflux Pump |
|---|---|---|
| Single seal (Arr. 1) | Plan 11 / 21 | NOT recommended – H₂S risk |
| Tandem seal (Arr. 2) | Plan 52 | Acceptable – buffer fluid collects leakage |
| Dual pressurized (Arr. 3) | Plan 53B (bladder accumulator) | Recommended – barrier fluid pressure > process, zero emissions |
Plan 53B with bladder accumulator provides:
Barrier fluid pressurised above process pressure using a nitrogen-charged bladder
No nitrogen entrainment into process (unlike Plan 53A with pressurised reservoir)
Visual level indicator and low pressure alarm
Absolute containment of H₂S-containing reflux fluid
Seal face materials: Silicon carbide (SiC) or tungsten carbide. Secondary seals: FKM (Viton) or Aflas for higher temperatures.
The reflux pump suction is typically taken from an atmospheric or low-pressure overhead accumulator / reflux drum. NPSHa is usually limited to 2–5 meters (drum elevation relative to pump centerline).
To ensure reliable operation without cavitation:
Select a pump with low NPSHr (optimized first-stage impeller design)
Consider an inducer option if NPSHa is marginal (<1.5 m above NPSHr)
Ensure NPSHa ≥ NPSHr + 1.0 m per API 610 recommendation
The fluid is near its bubble point (contains dissolved gases), so do NOT assume subcooling in NPSHa calculation
During start-up, shutdown, or low-demand periods, the reflux pump must be protected from operating below Minimum Continuous Stable Flow (MCSF). A minimum flow recirculation line (with orifice or automated recirculation valve) returns flow to the reflux drum to maintain safe pump operation.
| Application | Process | Typical Flow / Head |
|---|---|---|
| Natural gas sweetening | MDEA/MEA reflux after H₂S/CO₂ stripping | 20–300 m³/h @ 60–150 m |
| Refinery hydrodesulfurization (HDS) amine unit | Reflux of lean amine regenerator | 30–350 m³/h @ 80–180 m |
| Claus tail gas treatment (TGTU) | Amine regenerator reflux | 10–150 m³/h @ 50–120 m |
| CCUS (carbon capture) | Amine-based CO₂ capture regeneration | 40–400 m³/h @ 60–200 m |
| Syngas / ammonia plant | Amine wash unit regenerator reflux | 10–200 m³/h @ 40–120 m |
Design life: 20 years minimum
Continuous operation: Minimum 3 years uninterrupted service
Bearing life: L10 ≥25,000 hours (API 610 mandatory)
Critical speed: First lateral critical speed ≥120% of maximum operating speed
Centerline mounting (OH2): Accommodates thermal expansion in hot reflux service (up to 150°C)
Hydrostatic testing: Casing tested at 1.5x design pressure
Performance testing: Water performance test per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 (full traceability for all pressure-containing and wetted parts)
Full API 610 11th/12th edition compliance (ISO 13709) – 20-year life, 3-year continuous run
OH2 configuration – the industry standard for regenerator reflux duty; compact, easy to maintain
316L stainless steel (S-8) wetted parts – proven corrosion resistance in hot amine/H₂S/water service
API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S containment
Low NPSHr design – reliable operation even with limited suction head from reflux drum
Centerline mounting – maintains alignment during thermal cycling (reflux at 60–150°C)
Back pull-out design – rotor and seal replacement without disturbing piping
Minimum flow recirculation provisions – protects pump during turndown
Broad hydraulic coverage – flows 10–400 m³/h, heads 30–260 m, covering virtually all amine regenerator reflux applications
Field proven – thousands of API 610 OH2 pumps in amine reflux service worldwide
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 53B ready) | 1 set per pump |
| Bearing set (radial + thrust) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Gasket / O-ring kit | 1 set per pump |
| Inducer (if fitted) | 1 set |
For detailed selection of the correct Amine Regeneration Reflux Pump for your gas sweetening or refinery amine unit – including reflux flow and head calculation, NPSHa verification from overhead accumulator, material selection (316L SS or duplex for high-chloride service), API 682 seal plan (Plan 53B with bladder accumulator for H₂S service), and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
Our engineers support natural gas sweetening, refinery HDS, and carbon capture projects worldwide with reliable API 610 amine regeneration reflux pumps – ensuring safe, efficient regenerator operation.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.