Amine Transfer Pump – API 610 OH2 / BB3 / VS4 for Lean & Rich Amine Service

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 amine transfer pump for lean amine, rich amine, and MDEA solutions in gas sweetening and refinery desulfurization. OH2 single-stage, BB3 multistage, and VS4 vertical sump configurations. Flow up to 1,000 m³/h, head up to 260 m (OH2) or higher with BB3. 316L stainless steel (S-8) wetted parts. API 682 dual pressurized seals Plan 53B for H₂S containment. 20-year design life.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Amine Transfer Pump is purpose-built for transporting lean amine (regenerated, low acid gas content) and rich amine (loaded with H₂S and CO₂) across gas sweetening units, refinery hydrodesulfurization (HDS) plants, Claus tail gas treatment units, and carbon capture (CCUS) facilities. These pumps handle corrosive, toxic, and sometimes high-temperature amine solutions including MDEA, MEA, and DEA.

All pumps are fully compliant with API 610 11th/12th edition (ISO 13709) standards, guaranteeing a minimum 3‑year uninterrupted operation and a 20‑year design life. The series covers all typical amine transfer duties – from inter-tank transfer and sump evacuation to high‑pressure lean amine circulation.

Pump Configurations for Amine Transfer

Depending on flow, head, and installation requirements, three API 610 configurations are available.

Pump TypeConfigurationBest Amine Transfer Application
OH2Overhung, centreline-mounted, single-stageLean amine transfer between regenerator and absorber; rich amine transfer; tank-to-process transfer; flow up to 1,000 m³/h, head up to 260 m
BB3Axially split, single casing, multistage, between bearingsHigh‑head lean amine charge (exceeding 260 m) where high pressure is required; also for rich amine service in tall columns
VS4Vertical suspended sump/can typeSump evacuation; tank transfer with low NPSHa; fire-code compliant vertical installation in amine storage areas

OH2 – Standard Amine Transfer Pump

The OH2 configuration is the most frequently specified for amine transfer duties. Characteristics include:

  • Single-stage overhung impeller, centreline mounted for thermal stability

  • Back pull-out design – rotating assembly removable without disturbing piping

  • API 610 bearing housing with oil bath lubrication; L10 bearing life ≥25,000 hours

  • Flow up to 1,000 m³/h (higher with larger frames)

  • Head up to 260 m

  • Temperature –45°C to +200°C

  • Standard wetted material: 316L stainless steel (API 610 Class S‑8)

Ideal for lean amine circulation, rich amine transfer from absorber to regenerator, MDEA solution handling, and general process transfer.

BB3 – High‑Head Amine Transfer

For applications requiring head above 260 m (e.g., tall regenerator feed into high-pressure absorbers), the BB3 multistage pump provides:

  • Horizontally split single casing, between bearings

  • Opposed (back-to-back) impellers for axial thrust self‑balancing – no balance disc or drum

  • Dual volute or diffuser stages balancing radial thrust

  • Flow up to 1,500 m³/h, head up to 1,500 m, pressure up to 150 bar

  • Same material flexibility as OH2 (S‑8 standard, duplex optional)

VS4 – Vertical Sump Amine Transfer

When amine needs to be pumped from below‑grade sumps, spill collection pits, or low NPSHa tanks, the VS4 vertical suspended pump offers:

  • Vertically suspended, single or multistage, diffuser-type pump

  • Wet pit installation – suction strainer optional

  • Flow up to 750 m³/h, head up to 280 m, pressure up to 40 bar

  • Temperature –46°C to +260°C

  • Ideal for amine tank farm sumps, collection basins, and emergency transfer

Key Technical Specifications

ParameterOH2BB3VS4
Flow rangeUp to 1,000 m³/hUp to 1,500 m³/hUp to 750 m³/h
Head rangeUp to 260 mUp to 1,500 mUp to 280 m
Pressure ratingUp to 64 barUp to 150 barUp to 40 bar
Temperature–45 to +200°C–45 to +200°C–46 to +260°C
Speed1,450 / 2,950 rpm1,450 / 2,950 rpm1,450 / 2,950 rpm
Stages13 – 141 – 8

Materials – API 610 Table H

Amines (especially rich amine containing H₂S and CO₂) are corrosive. Proper material selection is critical.

ComponentRecommended Material (API 610 Class)Remarks
Casing316L stainless steel (S‑8)CF3M casting; resists pitting and general corrosion
Impeller316L stainless steel (S‑8)Same as casing
Shaft316 SS or 4140 with coatingCorrosion-resistant or hardened
Wear rings316L SS + Stellite hard-facingExtended life
GasketsSpiral wound (graphite filled)For flanges and casing joints
Fasteners316 SSPrevents galvanic corrosion

Carbon steel (C‑6) is not recommended for amine transfer because water, H₂S, and CO₂ cause rapid general corrosion and pitting. 316L SS (S‑8) is the industry standard and has proven successful for decades.

For amine streams with chlorides (e.g., from cooling water contamination) or very high H₂S partial pressures, duplex (D‑1/D‑2) or super duplex can be specified. NACE MR0175 / ISO 15156 compliance is available for sour amine service.

Mechanical Seals – API 682 Compliance

Rich amine contains H₂S – a toxic, hazardous gas. Lean amine is less hazardous but still requires containment. Dual pressurised seals are strongly recommended for all amine transfer pumps.

ServiceRecommended SealAPI 682 PlanNotes
Lean amine (low H₂S)Tandem seal (Arr. 2)Plan 52Buffer fluid collects any leakage
Lean amine (premium) / Rich amineDual pressurised (Arr. 3)Plan 53B (bladder accumulator)Zero emissions; barrier fluid pressure > process
Lean amine booster (clean, low pressure)Single seal (Arr. 1)Plan 11 / 21Acceptable only where H₂S is negligible

Plan 53B with bladder accumulator is the preferred arrangement for all H₂S‑containing amine transfer. It provides:

  • Barrier fluid pressurised above process pressure (no process leakage)

  • No nitrogen entrainment into process (unlike Plan 53A)

  • Visual level indicator and low‑pressure alarm

  • Compliance with strict refinery HSE requirements

Seal faces: Silicon carbide (SiC) / SiC or tungsten carbide for abrasive service. Elastomers: FKM (Viton) or Aflas for high‑temperature amine.

NPSH and Suction Conditions

Amine transfer pumps often take suction from:

  • Atmospheric storage tanks (NPSHa 2–5 m)

  • Reflux drums (low NPSHa)

  • Sump pits (NPSHa may be near zero)

To ensure reliable operation:

  • Select pumps with low NPSHr (optimised first‑stage impeller, large eye)

  • Consider inducer option for very low NPSHa

  • Maintain NPSHa ≥ NPSHr + 1.0 m per API 610

  • Do not assume subcooling – calculate NPSHa at bubble point because amine contains dissolved gases (H₂S, CO₂, methane)

Minimum Flow Protection

During start‑up, shutdown, or low‑demand periods, amine transfer pumps must be protected from low‑flow operation. A minimum flow recirculation line (with orifice or automated recirculation valve) returns flow to the suction source (tank or drum). This prevents overheating, cavitation, and mechanical seal damage.

Applications for Amine Transfer Pump

ApplicationFluidTypical DutyRecommended Configuration
Lean amine from regenerator to absorberLean MDEA/MEAQ 50–500 m³/h, H 50–250 mOH2
Rich amine from absorber to regeneratorRich MDEA/MEA (H₂S)Q 50–500 m³/h, H 50–150 mOH2
High‑pressure lean amine chargeLean amineQ 100–1000 m³/h, H >260 mBB3
Amine transfer from tank farm to processMDEA/MEAQ 30–300 m³/h, H 30–80 mOH2
Amine sump evacuationLean/rich amineQ 10–100 m³/h, H 20–60 mVS4
Amine make‑up / dump transferFresh amineQ 10–50 m³/h, H 20–60 mOH2 or VS4 (vertical)
CCUS amine circulationLean MEAQ 100–600 m³/h, H 60–200 mOH2

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Continuous operation: Minimum 3 years uninterrupted service

  • Bearing life: L10 ≥25,000 hours (API 610 mandatory)

  • Critical speed: First lateral critical speed ≥120% of maximum operating speed

  • Centerline mounting (OH2/BB3): Maintains alignment during thermal cycling

  • Hydrostatic testing: Casing tested at 1.5x design pressure

  • Performance testing: Water performance test per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 (full traceability for pressure‑containing parts)

  • NACE MR0175 / ISO 15156 optional for sour amine service

Why Choose Our Amine Transfer Pump?

  • Full API 610 compliance (OH2/BB3/VS4) – 11th/12th edition ISO 13709, 20‑year life, 3‑year continuous run

  • 316L stainless steel (S‑8) as standard – field‑proven corrosion resistance for all amine services

  • API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S‑containing rich amine

  • Broad hydraulic coverage – flows 10–1,500 m³/h, heads 20–1,500 m

  • Low NPSH designs – inducer option for challenging suction conditions

  • Centerline mounting – thermal stability for hot amine (up to 200°C)

  • Back pull‑out (OH2) / axial split (BB3) / vertical withdrawable (VS4) – reduced maintenance downtime

  • Minimum flow provisions – protect pump during turndown

  • NACE MR0175 / ISO 15156 compliant materials available – for sour amine with H₂S

  • Proven field experience – thousands of API 610 amine transfer pumps in gas plants and refineries worldwide

Recommended Spare Parts

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set per pump
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller)1 set
Gasket / O-ring kit1 set per pump
Inducer (if fitted)1 set

Get a Quote or Engineering Support

For detailed selection of the correct Amine Transfer Pump for your gas sweetening or refinery application – including flow and head calculations, NPSHa verification, material selection (316L SS S‑8 or duplex D‑1/D‑2 for chlorides), API 682 seal plan (Plan 53B for rich amine H₂S service), and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support natural gas sweetening, refinery HDS, carbon capture, and amine regeneration projects worldwide with reliable API 610 amine transfer pumps – from lean amine circulation to rich amine transfer.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit