The Amine Sump Pump is specifically designed for collecting and transferring lean amine, rich amine, and MDEA (methyl diethanolamine) solutions from low-level sumps, equipment drain pits, spill collection basins, and other below-grade locations in gas sweetening units, refinery amine regeneration areas, and carbon capture facilities.
Amine sump pumps operate in demanding conditions: the fluid often contains residual H₂S and CO₂, is corrosive, and may be at elevated temperatures. To ensure safety, reliability, and environmental compliance, these pumps are manufactured to API 610 11th/12th edition (ISO 13709) standards, providing a minimum 3‑year uninterrupted operation and a 20‑year design life.
The API 610 standard offers two primary configurations for sump applications, with the VS4 being the most common for amine sump duty.
| Pump Type | Configuration | Best Amine Sump Application |
|---|---|---|
| VS4 (Preferred) | Vertical suspended, wet pit, single or multistage, diffuser type | Below‑grade sumps, drain pits, collection basins; low NPSHa; space-constrained or fire-code areas |
| OH2 | Overhung, centerline-mounted, horizontal | Dry pit installations where sump is adjacent to pump room; above‑grade transfer from small collection tanks |
The VS4 configuration is the industry standard for amine sump service. Key characteristics include:
Vertically suspended pump column with suction bell or strainer immersed in the sump liquid
Wet pit installation – no suction piping required
Motor mounted on a discharge head above grade for easy access
Single or multistage diffuser-type hydraulics
Pump column length customised to sump depth
Discharge pipe integral with column, transporting fluid up to the grade-level discharge flange
Also available in a steam‑jacketed variant for molten sulfur or high‑temperature amine applications
Advantages for amine sump service:
Eliminates priming issues – impeller is always submerged
No suction piping means no additional NPSH loss
Ideal for low NPSHa – the vertical column of liquid provides net positive suction head
Compliant with fire codes that prohibit horizontal pumps in certain sump areas
Space‑efficient – footprint is limited to the discharge head diameter
When a conventional horizontal pump is preferred (e.g., for a small above‑grade amine collection tank or for maintenance convenience), the OH2 configuration can be used, provided the NPSHa from the tank is adequate. This is the same overhung, centerline-mounted pump described in other sections.
| Parameter | Range |
|---|---|
| Flow rate | Up to 750 m³/h (3,300 gpm) |
| Head | Up to 280 m (920 ft) |
| Pressure rating | Up to 40 bar (580 psi) |
| Temperature range | –46°C to +260°C (–50°F to +500°F) |
| Discharge sizes | 50 mm to 200 mm (2" to 8") |
| Pump column length | Custom – up to 6 meters (longer available) |
| Stages | 1 to 8 (depending on head requirement) |
| Speed | 1,450 / 2,950 rpm (50 Hz) or 1,750 / 3,550 rpm (60 Hz) |
Double casing (optional): For high-pressure or high-temperature amine sump service, a VS6 (double casing vertical) may be specified, but VS4 (single casing) is adequate for typical atmospheric or low‑pressure sumps.
Line shaft construction: The motor drives a vertical shaft running inside the pump column, supported by line shaft bearings lubricated by the pumped fluid. For amine service, bearings are selected for compatibility with amine solutions (non‑degrading materials).
Discharge head: The motor is mounted on a fabricated steel or cast iron discharge head above grade. The head contains the discharge nozzle, stuffing box (seal chamber), and vent connections.
Thrust bearing: Located in the discharge head or motor adapter, handles the hydraulic down‑thrust of the rotating element. Sized for 25,000‑hour L10 life per API 610.
Seal chamber: Located at the discharge head, above the liquid level. This allows easy maintenance access and allows the mechanical seal to operate in a clean, non‑submerged environment.
Amine sump fluid is typically a mixture of water, amine (MDEA/MEA/DEA), H₂S, CO₂, and possibly hydrocarbon carryover. Corrosion resistance is essential.
| Component | Recommended Material (API 610 Class) | Remarks |
|---|---|---|
| Pump column / discharge pipe | 316L stainless steel (S‑8) | Resistance to amine and H₂S corrosion |
| Diffuser casings | 316L stainless steel (S‑8) | CF3M casting |
| Impellers | 316L stainless steel (S‑8) | Single or multistage |
| Impeller wear rings | 316L SS + Stellite hard‑facing | Abrasion resistance |
| Shaft (line shaft) | 316 SS or 17‑4 PH with coating | Corrosion‑resistant |
| Discharge head | 316L SS or carbon steel with 316L cladding | Carbon steel acceptable if not wetted |
| Fasteners | 316 SS | Prevents galvanic corrosion |
| Casing gaskets | Spiral wound (graphite filled) | For flanged joints |
For amine sumps with high chloride levels (e.g., from cooling water ingress), duplex (D‑1/D‑2) or super duplex materials may be specified. NACE MR0175 / ISO 15156 compliance is available for sour service (H₂S partial pressure exceeding limits).
316L stainless steel (S‑8) is the standard and most cost-effective material for amine sump pumps. Carbon steel casings will corrode rapidly in amine/H₂S/water service.
The sump pump mechanical seal is located in the discharge head, above the liquid level. However, the seal still contacts the pumped amine fluid via the stuffing box. Because the fluid may contain H₂S, dual seals are strongly recommended.
| Service | Recommended Seal | API 682 Plan | Notes |
|---|---|---|---|
| Lean amine sump (low H₂S) | Tandem seal (Arr. 2) | Plan 52 | Buffer fluid collects any leakage; acceptable for indoor/well‑ventilated areas |
| Rich amine sump (H₂S present) | Dual pressurized (Arr. 3) | Plan 53B (bladder accumulator) | Zero emissions; barrier fluid pressure > process; mandatory for H₂S containment |
| Any amine sump (premium specification) | Dual pressurized (Arr. 3) | Plan 53B | Recommended by major EPCs for all amine sump pumps |
Plan 53B provides barrier fluid pressurised above process pressure using a bladder accumulator (no nitrogen entrainment into process). It includes a reservoir with level indicator and low‑pressure alarm.
Because the seal is above the liquid level, it is not exposed to solids that may settle at the bottom of the sump. However, seal faces must still be corrosion and abrasion resistant: silicon carbide (SiC) / silicon carbide or tungsten carbide.
Elastomers: FKM (Viton) for moderate temperatures; Aflas for high‑temperature amine sump service.
The VS4 pump takes suction from a bellmouth or strainer at the bottom of the pump column, submerged in the sump liquid. The available NPSH is calculated as:
NPSHa = (atmospheric pressure) + (vertical height of liquid above impeller inlet) – (vapour pressure of fluid at sump temperature) – (suction strainer and friction losses)
In amine sump service, the sump may be shallow or liquid level may vary. To ensure reliable operation:
Minimum submergence must be maintained (per API 610 and pump manufacturer data) to prevent vortexing.
A low‑level shutdown switch is recommended to protect the pump from running dry.
For sumps with very low or fluctuating levels, consider a larger column extension or a float-controlled level system.
Because amine solutions can be foaming, special attention to suction strainer design and column venting is required.
Amine sump pumps are typically intermittent duty – they start when sump level reaches a high setpoint and stop at low level. To prevent damage during low‑flow or no‑flow conditions:
A minimum flow recirculation line is not normally required for intermittent sump service, as the pump does not operate continuously against a closed valve.
However, a thermal protection device (temperature switch on discharge head) or a power monitoring relay can detect dry run.
Level control interlock must ensure the pump stops before the impeller is uncovered.
For continuous duty applications (e.g., pumping from a constantly filling sump), a minimum flow bypass to the sump may be required.
| Application | Description | Typical Fluid |
|---|---|---|
| Amine drain sump | Collecting drips, leaks, and drains from amine pumps, valves, and flanges around regenerator and absorber | Lean/rich amine, water |
| Spill collection basin | Emergency containment area around amine storage tanks or process vessels | MDEA, MEA, DEA |
| Amine tank farm drain pit | From amine storage tank sumps or dike drains | Lean amine |
| Regenerator bottom sump | Collecting amine from regenerator bottoms during maintenance or from seal leaks | Hot rich amine, H₂S |
| Sample station drain | Collection of amine samples from sampling points | Lean/rich amine |
| Carbon capture amine sump | Drain collection from amine‑based CO₂ capture systems | MEA solution |
Design life: 20 years minimum
Continuous operation (if required): Minimum 3 years uninterrupted service
Bearing life (thrust bearing): L10 ≥25,000 hours (API 610 mandatory)
Critical speed: First lateral critical speed ≥120% of maximum operating speed
Hydrostatic testing: Discharge head and column tested at 1.5x design pressure
Performance testing: Water performance test per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 (full traceability for pressure‑containing parts)
NACE MR0175 / ISO 15156 optional for sour amine sump service
Full API 610 VS4 compliance – 11th/12th edition ISO 13709, 20‑year life
Vertical wet pit design – eliminates priming, suction piping, and low NPSH concerns
316L stainless steel (S‑8) wetted parts – field‑proven corrosion resistance for all amine services
API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S‑containing amine sump
Custom column lengths – suited to your sump depth
Low NPSHr – reliable operation even with shallow sumps
Single or multistage – covers low to medium head requirements (up to 280 m)
Easy maintenance – seal and bearings accessible at grade level without removing the pump column
Level control options – float switches, transducers, or level controllers available
NACE MR0175 / ISO 15156 compliance available – for sour amine sump service
Proven installations – thousands of VS4 amine sump pumps in gas plants, refineries, and CCUS facilities worldwide
Installation:
The sump must be clean and free of debris before installation.
Column length must be selected so the suction strainer is at least 0.5 m above sump bottom to avoid sludge ingestion.
Minimum submergence at start‑up must be maintained per manufacturer's curve.
Discharge piping should be independently supported to avoid loads on the pump discharge head.
Maintenance:
The entire rotating assembly (shaft, impellers, column, line shaft bearings) can be withdrawn upward through the discharge head.
Seal replacement: access at grade level – remove motor and adapter, then withdraw the seal cartridge.
Bearing replacement: thrust bearing located in discharge head or motor adapter – accessible from top.
For heavy pumps, a davit or small crane is required for removing the column assembly.
Recommended Spare Parts
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 53B ready) | 1 set per pump |
| Thrust bearing set | 1 set |
| Line shaft bearing set | 1 set per column section |
| Wear ring set | 1 set |
| Gasket / O-ring kit | 1 set per pump |
For detailed selection of the correct Amine Sump Pump for your gas sweetening or refinery amine unit – including sump depth and NPSHa calculation, material selection (316L SS S‑8 standard, duplex for high chlorides), API 682 seal plan (Plan 53B for H₂S service), level control integration, and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
Our engineers support natural gas sweetening, refinery HDS, carbon capture, and amine regeneration projects worldwide with reliable API 610 amine sump pumps – safe, corrosion‑resistant, and emissions‑compliant.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.