API 610 amine sump pump for collecting and transferring lean amine, rich amine, and MDEA solutions from sumps, drain pits, and spill collection basins. VS4 vertical suspended configuration (standard), with OH2 option for dry pit installations. 316L stainless steel (S-8) wetted parts. API 682 dual pressurized seals Plan 53B for H₂S containment. Flow up to 750 m³/h, head up to 280 m. 20-year design life, 3-year continuous run.

Conatct For Details
DetailReview(0)Additional

Product Overview

The Amine Sump Pump is specifically designed for collecting and transferring lean amine, rich amine, and MDEA (methyl diethanolamine) solutions from low-level sumps, equipment drain pits, spill collection basins, and other below-grade locations in gas sweetening units, refinery amine regeneration areas, and carbon capture facilities.

Amine sump pumps operate in demanding conditions: the fluid often contains residual H₂S and CO₂, is corrosive, and may be at elevated temperatures. To ensure safety, reliability, and environmental compliance, these pumps are manufactured to API 610 11th/12th edition (ISO 13709) standards, providing a minimum 3‑year uninterrupted operation and a 20‑year design life.

Pump Configurations for Amine Sump Service

The API 610 standard offers two primary configurations for sump applications, with the VS4 being the most common for amine sump duty.

Pump TypeConfigurationBest Amine Sump Application
VS4 (Preferred)Vertical suspended, wet pit, single or multistage, diffuser typeBelow‑grade sumps, drain pits, collection basins; low NPSHa; space-constrained or fire-code areas
OH2Overhung, centerline-mounted, horizontalDry pit installations where sump is adjacent to pump room; above‑grade transfer from small collection tanks

VS4 – Vertical Sump Pump (Preferred)

The VS4 configuration is the industry standard for amine sump service. Key characteristics include:

  • Vertically suspended pump column with suction bell or strainer immersed in the sump liquid

  • Wet pit installation – no suction piping required

  • Motor mounted on a discharge head above grade for easy access

  • Single or multistage diffuser-type hydraulics

  • Pump column length customised to sump depth

  • Discharge pipe integral with column, transporting fluid up to the grade-level discharge flange

  • Also available in a steam‑jacketed variant for molten sulfur or high‑temperature amine applications

Advantages for amine sump service:

  • Eliminates priming issues – impeller is always submerged

  • No suction piping means no additional NPSH loss

  • Ideal for low NPSHa – the vertical column of liquid provides net positive suction head

  • Compliant with fire codes that prohibit horizontal pumps in certain sump areas

  • Space‑efficient – footprint is limited to the discharge head diameter

OH2 – Horizontal Dry Pit Option

When a conventional horizontal pump is preferred (e.g., for a small above‑grade amine collection tank or for maintenance convenience), the OH2 configuration can be used, provided the NPSHa from the tank is adequate. This is the same overhung, centerline-mounted pump described in other sections.

Key Technical Specifications (VS4 Amine Sump Pump)

ParameterRange
Flow rateUp to 750 m³/h (3,300 gpm)
HeadUp to 280 m (920 ft)
Pressure ratingUp to 40 bar (580 psi)
Temperature range–46°C to +260°C (–50°F to +500°F)
Discharge sizes50 mm to 200 mm (2" to 8")
Pump column lengthCustom – up to 6 meters (longer available)
Stages1 to 8 (depending on head requirement)
Speed1,450 / 2,950 rpm (50 Hz) or 1,750 / 3,550 rpm (60 Hz)

Sump Pump Design Features – API 610 VS4

Double casing (optional): For high-pressure or high-temperature amine sump service, a VS6 (double casing vertical) may be specified, but VS4 (single casing) is adequate for typical atmospheric or low‑pressure sumps.

Line shaft construction: The motor drives a vertical shaft running inside the pump column, supported by line shaft bearings lubricated by the pumped fluid. For amine service, bearings are selected for compatibility with amine solutions (non‑degrading materials).

Discharge head: The motor is mounted on a fabricated steel or cast iron discharge head above grade. The head contains the discharge nozzle, stuffing box (seal chamber), and vent connections.

Thrust bearing: Located in the discharge head or motor adapter, handles the hydraulic down‑thrust of the rotating element. Sized for 25,000‑hour L10 life per API 610.

Seal chamber: Located at the discharge head, above the liquid level. This allows easy maintenance access and allows the mechanical seal to operate in a clean, non‑submerged environment.

Materials – API 610 Table H

Amine sump fluid is typically a mixture of water, amine (MDEA/MEA/DEA), H₂S, CO₂, and possibly hydrocarbon carryover. Corrosion resistance is essential.

ComponentRecommended Material (API 610 Class)Remarks
Pump column / discharge pipe316L stainless steel (S‑8)Resistance to amine and H₂S corrosion
Diffuser casings316L stainless steel (S‑8)CF3M casting
Impellers316L stainless steel (S‑8)Single or multistage
Impeller wear rings316L SS + Stellite hard‑facingAbrasion resistance
Shaft (line shaft)316 SS or 17‑4 PH with coatingCorrosion‑resistant
Discharge head316L SS or carbon steel with 316L claddingCarbon steel acceptable if not wetted
Fasteners316 SSPrevents galvanic corrosion
Casing gasketsSpiral wound (graphite filled)For flanged joints

For amine sumps with high chloride levels (e.g., from cooling water ingress), duplex (D‑1/D‑2) or super duplex materials may be specified. NACE MR0175 / ISO 15156 compliance is available for sour service (H₂S partial pressure exceeding limits).

316L stainless steel (S‑8) is the standard and most cost-effective material for amine sump pumps. Carbon steel casings will corrode rapidly in amine/H₂S/water service.

Mechanical Seals – API 682 Compliance

The sump pump mechanical seal is located in the discharge head, above the liquid level. However, the seal still contacts the pumped amine fluid via the stuffing box. Because the fluid may contain H₂S, dual seals are strongly recommended.

ServiceRecommended SealAPI 682 PlanNotes
Lean amine sump (low H₂S)Tandem seal (Arr. 2)Plan 52Buffer fluid collects any leakage; acceptable for indoor/well‑ventilated areas
Rich amine sump (H₂S present)Dual pressurized (Arr. 3)Plan 53B (bladder accumulator)Zero emissions; barrier fluid pressure > process; mandatory for H₂S containment
Any amine sump (premium specification)Dual pressurized (Arr. 3)Plan 53BRecommended by major EPCs for all amine sump pumps

Plan 53B provides barrier fluid pressurised above process pressure using a bladder accumulator (no nitrogen entrainment into process). It includes a reservoir with level indicator and low‑pressure alarm.

Because the seal is above the liquid level, it is not exposed to solids that may settle at the bottom of the sump. However, seal faces must still be corrosion and abrasion resistant: silicon carbide (SiC) / silicon carbide or tungsten carbide.

Elastomers: FKM (Viton) for moderate temperatures; Aflas for high‑temperature amine sump service.

Suction and NPSH for VS4 Sump Pumps

The VS4 pump takes suction from a bellmouth or strainer at the bottom of the pump column, submerged in the sump liquid. The available NPSH is calculated as:

NPSHa = (atmospheric pressure) + (vertical height of liquid above impeller inlet) – (vapour pressure of fluid at sump temperature) – (suction strainer and friction losses)

In amine sump service, the sump may be shallow or liquid level may vary. To ensure reliable operation:

  • Minimum submergence must be maintained (per API 610 and pump manufacturer data) to prevent vortexing.

  • A low‑level shutdown switch is recommended to protect the pump from running dry.

  • For sumps with very low or fluctuating levels, consider a larger column extension or a float-controlled level system.

Because amine solutions can be foaming, special attention to suction strainer design and column venting is required.

Minimum Flow and Dry Run Protection

Amine sump pumps are typically intermittent duty – they start when sump level reaches a high setpoint and stop at low level. To prevent damage during low‑flow or no‑flow conditions:

  • A minimum flow recirculation line is not normally required for intermittent sump service, as the pump does not operate continuously against a closed valve.

  • However, a thermal protection device (temperature switch on discharge head) or a power monitoring relay can detect dry run.

  • Level control interlock must ensure the pump stops before the impeller is uncovered.

For continuous duty applications (e.g., pumping from a constantly filling sump), a minimum flow bypass to the sump may be required.

Applications for Amine Sump Pump

ApplicationDescriptionTypical Fluid
Amine drain sumpCollecting drips, leaks, and drains from amine pumps, valves, and flanges around regenerator and absorberLean/rich amine, water
Spill collection basinEmergency containment area around amine storage tanks or process vesselsMDEA, MEA, DEA
Amine tank farm drain pitFrom amine storage tank sumps or dike drainsLean amine
Regenerator bottom sumpCollecting amine from regenerator bottoms during maintenance or from seal leaksHot rich amine, H₂S
Sample station drainCollection of amine samples from sampling pointsLean/rich amine
Carbon capture amine sumpDrain collection from amine‑based CO₂ capture systemsMEA solution

API 610 Compliance Highlights

  • Design life: 20 years minimum

  • Continuous operation (if required): Minimum 3 years uninterrupted service

  • Bearing life (thrust bearing): L10 ≥25,000 hours (API 610 mandatory)

  • Critical speed: First lateral critical speed ≥120% of maximum operating speed

  • Hydrostatic testing: Discharge head and column tested at 1.5x design pressure

  • Performance testing: Water performance test per API 610 Grade 1 or 2

  • Material certification: EN 10204 3.1 (full traceability for pressure‑containing parts)

  • NACE MR0175 / ISO 15156 optional for sour amine sump service

Why Choose Our Amine Sump Pump?

  • Full API 610 VS4 compliance – 11th/12th edition ISO 13709, 20‑year life

  • Vertical wet pit design – eliminates priming, suction piping, and low NPSH concerns

  • 316L stainless steel (S‑8) wetted parts – field‑proven corrosion resistance for all amine services

  • API 682 Plan 53B dual pressurised seals – zero emissions, mandatory for H₂S‑containing amine sump

  • Custom column lengths – suited to your sump depth

  • Low NPSHr – reliable operation even with shallow sumps

  • Single or multistage – covers low to medium head requirements (up to 280 m)

  • Easy maintenance – seal and bearings accessible at grade level without removing the pump column

  • Level control options – float switches, transducers, or level controllers available

  • NACE MR0175 / ISO 15156 compliance available – for sour amine sump service

  • Proven installations – thousands of VS4 amine sump pumps in gas plants, refineries, and CCUS facilities worldwide

Installation and Maintenance Considerations

Installation:

  • The sump must be clean and free of debris before installation.

  • Column length must be selected so the suction strainer is at least 0.5 m above sump bottom to avoid sludge ingestion.

  • Minimum submergence at start‑up must be maintained per manufacturer's curve.

  • Discharge piping should be independently supported to avoid loads on the pump discharge head.

Maintenance:

  • The entire rotating assembly (shaft, impellers, column, line shaft bearings) can be withdrawn upward through the discharge head.

  • Seal replacement: access at grade level – remove motor and adapter, then withdraw the seal cartridge.

  • Bearing replacement: thrust bearing located in discharge head or motor adapter – accessible from top.

  • For heavy pumps, a davit or small crane is required for removing the column assembly.

Recommended Spare Parts

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set per pump
Thrust bearing set1 set
Line shaft bearing set1 set per column section
Wear ring set1 set
Gasket / O-ring kit1 set per pump

Get a Quote or Engineering Support

For detailed selection of the correct Amine Sump Pump for your gas sweetening or refinery amine unit – including sump depth and NPSHa calculation, material selection (316L SS S‑8 standard, duplex for high chlorides), API 682 seal plan (Plan 53B for H₂S service), level control integration, and complete API 610 data sheet – please contact our engineering team.

Email: info@hyrig.com

Our engineers support natural gas sweetening, refinery HDS, carbon capture, and amine regeneration projects worldwide with reliable API 610 amine sump pumps – safe, corrosion‑resistant, and emissions‑compliant.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit