The Flare Knockout Pump is designed to remove accumulated liquids from the flare knockout drum (also called flare KO drum or flare scrubber) in refinery, petrochemical, and gas plant flare systems. The flare header collects relief and blowdown gases from multiple sources during normal operation, start‑up, shutdown, or emergency depressurisation. Entrained liquids – including hydrocarbon condensate, water, caustic, sour water, and amine carryover – must be removed from the gas stream before flaring to prevent liquid carryover to the flare tip (which causes smoking, burning rain, and environmental violations). The knockout drum separates these liquids, and the flare knockout pump transfers them to slop, drain, or recovery systems.
Given the intermittent duty, variable liquid composition (hydrocarbons, water, H₂S, caustic, and sometimes solids), and potentially low NPSHa, these pumps are engineered to API 610 11th/12th edition (ISO 13709) standards for reliability, safety, and environmental compliance. The design life is 20 years with minimum 3‑year uninterrupted operation, despite the challenging service.
The choice of pump type depends on installation layout, NPSHa, and maintenance philosophy.
| Pump Type | Configuration | Best Flare Knockout Application |
|---|---|---|
| OH2 (Preferred) | Overhung, centerline-mounted, single-stage | Above‑grade installation near KO drum; adequate NPSHa (drum elevation typically 3–6 m above pump centreline); easy access for maintenance |
| VS4 | Vertical suspended sump (wet pit) | Below‑grade sump or tight footprint; fire‑code requirement; drum located at grade with pump in adjacent pit |
| BB3 (rare) | Axially split multistage | Only required if very high head needed (e.g., pumping to distant storage); rarely used for KO drum |
The OH2 horizontal pump is the most common selection. Characteristics include:
Single-stage overhung impeller, centreline mounted
Back pull-out design – rotating assembly removable without disturbing piping
API 610 bearing housing with oil bath; L10 bearing life ≥25,000 hours
Flow range: 10 – 500 m³/h (larger KO drums may require higher flows)
Head range: 30 – 150 m (typically 50–100 m, depending on discharge routing)
Temperature range: –45°C to +200°C
Materials: Carbon steel (C-6) for clean hydrocarbon; 316L SS (S-8) for sour/corrosive service
The pump normally operates intermittently – started by a level switch on the knockout drum. It may be arranged with an automatic recirculation valve to prevent dead‑heading if the downstream line is blocked.
When the knockout drum is at grade and no space or NPSHa for a horizontal pump exists, a VS4 vertical sump pump can be installed in a small pit adjacent to the drum, taking suction directly from the drum via a short pipe or from a small sump collecting the KO drum liquid. This configuration is less common for flare KO drums but is selected for offshore platforms or space‑constrained revamps.
VS4 features include:
Vertically suspended, single or multistage, diffuser type
Wet pit or direct‑connected to drum nozzle
Motor above grade for easy access
Flow up to 400 m³/h, head up to 150 m
Material same as OH2
| Parameter | OH2 (Standard) | VS4 (Optional) |
|---|---|---|
| Flow range | 10 – 500 m³/h | 10 – 400 m³/h |
| Head range | 30 – 150 m | 20 – 150 m |
| Pressure rating | Up to 64 bar | Up to 40 bar |
| Temperature | –45 to +200°C | –46 to +200°C |
| Speed | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm |
| Duty | Intermittent (level controlled) | Intermittent / continuous |
The liquid accumulated in the knockout drum is a variable mixture that depends on upstream unit operations. Typical components include:
Hydrocarbons (gasoline, diesel, heavy oils, naphtha)
Sour water (H₂S and NH₃)
Caustic solutions (from caustic wash units)
Amine solutions (MDEA/MEA from amine regeneration vents)
Condensed steam or water
Small amounts of solids (catalyst fines, rust, coke)
Because the composition is unpredictable, the pump must tolerate a wide range of density, viscosity, pH, and potential H₂S levels. Corrosion and erosion considerations vary.
| Liquid Type | Corrosiveness | Material Recommendation |
|---|---|---|
| Clean hydrocarbon condensate | Low | Carbon steel (C-6) |
| Sour hydrocarbon + H₂O + H₂S | High | 316L SS (S-8) with NACE MR0175 |
| Caustic carryover | Moderate to high | 316L SS (S-8) – avoid carbon steel |
| Amine carryover | Moderate | 316L SS (S-8) |
| Water + chlorides + H₂S | High | Duplex (D-1/D-2) with NACE |
316L stainless steel (S-8) is recommended for most flare knockout pumps because the liquid composition is rarely known with certainty, and carbon steel may fail prematurely if H₂S or caustic appears unexpectedly.
Flare knockout liquids can be hazardous (H₂S, flammable hydrocarbons). Seal selection must ensure containment.
| Service Severity | Recommended Seal | API 682 Plan | Notes |
|---|---|---|---|
| Hydrocarbon condensate (non‑H₂S) | Single seal (Arr. 1) | Plan 11 / 21 | Self‑flush from pump discharge |
| Sour / H₂S service | Dual pressurized (Arr. 3) | Plan 53B | Zero emissions; bladder accumulator |
| Variable composition (default) | Dual pressurized (Arr. 3) | Plan 53B | Provides highest reliability and compliance |
If the KO liquid contains solids or is prone to coking, consider an external flush (Plan 32) with compatible clean fluid.
For intermittent operation, seal faces should be silicon carbide (SiC) or tungsten carbide. Elastomers: FKM (Viton) for moderate temperatures; Aflas for higher temperature or caustic service.
The flare knockout drum is typically elevated 3–6 meters above grade, and the pump is installed at grade. This provides NPSHa of approximately 4–8 meters (after accounting for drum pressure – near atmospheric – and liquid vapour pressure).
NPSHa = (drum liquid level above pump centreline) – (vapour pressure of liquid at operating temperature) – (suction line friction)
The liquid may be near its bubble point because flare headers operate just above atmospheric pressure.
Ensure NPSHa ≥ NPSHr + 1.0 m per API 610.
For low vapour pressure liquids (e.g., heavy hydrocarbon condensate), NPSH is typically adequate.
If the knockout drum is not elevated (e.g., at grade only a few feet above pump), NPSHa may be marginal – then a VS4 vertical pump (with submerged suction) or a pump with inducer may be required.
Flare knockout pumps are almost always started and stopped by a level controller on the KO drum:
High level (L H): start pump
Low level (L L): stop pump
Low‑low level interlock: pump stop to prevent dry run
A time delay on starting is often included to prevent short cycling.
Because the pump may run dry for brief periods after the drum empties, thermal protection (temperature sensor on casing or bearing housing) should be provided.
During intermittent operation, the pump discharges against a normally open valve to a slop system or storage tank. If the discharge valve closes (e.g., downstream line blocked), the pump must be protected. Options:
Automatic recirculation valve (ARC) integrated with the pump baseplate, ensuring minimum flow returns to the knockout drum or suction source.
External bypass line with orifice sized for minimum continuous stable flow, continuously recirculating.
For intermittent duty with reliable downstream path, an ARC is preferred.
| Facility | Typical Liquid | Duty Cycle |
|---|---|---|
| Refinery flare system | Hydrocarbon + sour water + H₂S | Intermittent (during relief events or normal blowdown) |
| Petrochemical plant flare | Olefins, aromatics, water | Intermittent |
| LNG / gas plant flare | Condensate, water, amines | Intermittent |
| Offshore platform (FPSO) | Hydrocarbon + produced water | Intermittent (level controlled) |
| Terminal / tank farm flare | Vapour condensate | Intermittent |
Design life: 20 years minimum
Bearing life: L10 ≥25,000 hours
Centerline mounting (OH2): Thermal stability for any temperature liquid
Hydrostatic test: 1.5x design pressure
Performance test: Water per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 (full traceability)
NACE MR0175 / ISO 15156 certification available for sour flare liquid
API 610 full compliance (OH2/VS4) – 11th/12th edition, 20‑year life
Material flexibility – Carbon steel (C-6), 316L SS (S‑8), or duplex (D‑1/D‑2) to match unknown or variable flare liquid composition
316L SS recommended as minimum – handles H₂S, caustic, amine carryover without premature failure
API 682 Plan 53B dual seals – zero emissions for H₂S or hydrocarbon service
Level control integration – pump starts/stops automatically based on KO drum level
Low NPSH designs + inducer option for low‑elevation KO drums
Robust intermittent duty design – suitable for frequent start‑stop cycles
Minimum flow protection via ARC or bypass
ATEX compliant motor available for Zone 1/2 hazardous areas
Proven in refineries and petrochemical plants worldwide
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (Plan 53B ready) | 1 set per pump |
| Bearing set | 1 set |
| Wear ring set | 1 set |
| Gasket / O-ring kit | 1 set |
For detailed selection of the correct Flare Knockout Pump for your refinery, petrochemical, or gas plant flare system – including NPSHa calculation from KO drum elevation, material selection based on expected flare condensate composition (carbon steel, 316L SS, or duplex), API 682 seal plan (Plan 53B for H₂S service), level control integration, and complete API 610 data sheet – please contact our engineering team.