API 610 OH1 foot‑mounted centrifugal pump (radially split, end suction, overhung, single‑stage) specifically engineered for ammonium chloride crystallization and separation circuits in Hou`s process / Union process soda ash plants. Handles cold, high‑chloride brine (NH₄Cl / NaCl solution) at -5 to 25°C with entrained crystals. Duplex stainless steel (2205/2507) or super austenitic (904L/254 SMO) wetted parts. Abrasion‑resistant mechanical seal with external flush (Plan 32). Manufactured by a certified China API 610 pump manufacturer with full API Q1 certification. Flow 50‑500 m³/h, head 20‑60 m. 20‑year design life, 3‑year continuous operation.

Conatct For Details
DetailReview(0)Additional

Product Overview

The ammonium chloride crystallization circulation pump is a specialised centrifugal pump designed for circulating cold, high‑chloride brine in the ammonium chloride crystallization and separation circuit of soda ash production plants using Hou`s process (combined process / Union process). After carbonation and mother liquor treatment, the ammonium chloride (NH₄Cl) is crystallised from the mother liquor by cooling. The crystallization circuit requires circulation of the cold brine (‑5 to 25°C) containing high concentrations of ammonium chloride and sodium chloride, together with entrained NH₄Cl crystals, through crystallizers, cooling sections, and to centrifuges or filters for crystal separation.

This service is extremely challenging due to:

  • High chloride concentration (Cl⁻ > 80,000 ppm) – very corrosive, leading to pitting and crevice corrosion of standard stainless steels.

  • Low temperature (‑5 to 25°C) – thermal stress on materials; also risk of salt precipitation if temperature fluctuates.

  • Entrained crystals – fine NH₄Cl crystals can be abrasive and cause seal and wear ring wear.

  • Corrosive ammonia – the mother liquor contains free ammonia, which attacks copper alloys and some elastomers.

The pump is classified under API 610 (ISO 13709) as Type OH1 – an overhung, foot‑mounted, radially split, single‑stage centrifugal pump. The OH1 foot mounting is suitable for low‑to‑medium temperature service (‑5 to 25°C, well within the capacity of foot‑mounted pumps) and provides a robust, accessible design with back pull‑out for easy seal and impeller maintenance.

This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, extensive experience in corrosion‑resistant alloys, and thousands of OH1 pumps operating in ammonium chloride crystallization circuits worldwide.

Construction & API 610 Classification

FeatureDescription
API 610 TypeOH1 (overhung, foot‑mounted, radially split, single‑stage)
Casing formRadially split volute, foot‑mounted
Bearing supportOverhung – impeller overhangs from bearing housing; bearings at drive end only
Number of stagesSingle stage
Suction typeEnd suction, single‑suction
Discharge orientationTop or side discharge (as required)
Flange ratingANSI Class 150 / 300 (as required)
ComplianceAPI 610 11th / 12th edition (ISO 13709)

Why OH1 for Ammonium Chloride Crystallization Circulation

  • Foot‑mounted simplicity – For low‑temperature service (‑5 to 25°C), centreline mounting is not required; foot‑mounting is sufficient and reduces cost while still meeting API 610 requirements.

  • Overhung design – Compact, easy to maintain, with back pull‑out capability.

  • Radially split casing – Provides good pressure containment and allows access to the rotor.

  • Back pull‑out design – The entire rotating assembly can be removed without disconnecting piping – essential for pumps that require frequent seal replacement due to abrasive crystals.

  • Single‑stage open passages – Wide internal flow paths allow entrained crystals to pass without clogging.

Key Technical Specifications (Ammonium Chloride Crystallization Duty)

ParameterDesign Range
Flow rate50 – 500 m³/h (220 – 2,200 GPM)
Head20 – 60 m (65 – 195 ft)
Fluid temperature-5 to 25°C (23 to 77°F)
Fluid compositionAmmonium chloride (NH₄Cl) ‑ brine ~25‑28%, sodium chloride, free ammonia, fine NH₄Cl crystals
Chloride concentration> 80,000 ppm (8%+), highly corrosive
Solids content5‑10% fine NH₄Cl crystals (entrained)
Specific gravity1.10 – 1.20
pH7 – 9 (ammoniacal)
Maximum pressure1.5 – 2.5 MPa (15 – 25 bar)
Speed1,450 / 2,900 rpm (50Hz) or 1,750 / 3,500 rpm (60Hz)
NPSHrOptimised (<3‑5 m) – inducer option for low NPSHa
Pump efficiency65‑78% (depending on size and crystal loading)
Design life20 years minimum

Materials – Duplex / Super Duplex / Super Austenitic Stainless Steel

Standard 316L stainless steel (S‑8) is not sufficient for prolonged exposure to chloride concentrations > 50,000 ppm, especially in the presence of crevices and low temperature. Higher alloys are required.

ComponentRecommended MaterialAPI 610 ClassPREN Value
CasingDuplex 2205 or Super Duplex 2507D‑1 / D‑235‑42
ImpellerDuplex 2205 or Super Duplex 2507D‑1 / D‑235‑42
ShaftDuplex 2205 or Super DuplexD‑1 / D‑2–
Wear ringsDuplex + Stellite / tungsten carbide––
Seal chamberDuplex or super austenitic (904L / 254 SMO)––
FastenersDuplex or super duplex––
GasketsPTFE or Viton (FKM)––

Material Recommendations by Chloride Level

Chloride concentrationRecommended materialPRENRemarks
20,000 – 50,000 ppm316L (S‑8)25‑30Marginal for long term, not recommended for NH₄Cl brine
50,000 – 100,000 ppmDuplex 2205 (D‑1)35‑38Standard choice for NH₄Cl crystallization
100,000 – 150,000 ppmSuper Duplex 2507 (D‑2 / U‑8)>40For high Cl⁻ and low pH conditions
Very high + risk of creviceSuper austenitic (904L, 254 SMO)35‑43Alternative to super duplex

For ammonium chloride crystallization circuits, Duplex 2205 (API 610 Class D‑1) is the most cost‑effective and proven material. For particularly aggressive conditions or higher Cl⁻ concentrations, Super Duplex 2507 (Class D‑2/U‑8) is recommended.

All materials supplied with EN 10204 Type 3.1 certification and full traceability. NACE MR0175 is not typically required for this service (no H₂S), but can be provided on request.

Mechanical Seals – API 682 for Low‑Temperature, Solids‑Laden Brine

The cold ammonium chloride brine contains fine NH₄Cl crystals that can abrade seal faces and cause seal failure. Additionally, the low temperature can cause elastomer hardening.

Seal ArrangementAPI 682 PlanSuitability
Single seal with external clean flushPlan 32Highly recommended – continuous injection of clean external fluid (warm water or clarified brine at 10‑20°C) flushes crystals away from seal faces
Dual pressurised (Arrangement 3)Plan 53BZero emissions, but must be combined with Plan 32 or barrier fluid heating to avoid low‑temperature issues
Single seal with quenchPlan 62Not sufficient for crystalline slurries

Recommended Seal Face Materials

  • Silicon carbide vs. tungsten carbide – Tungsten carbide faces are very hard (>1,800 Hv) and resist abrasion from NH₄Cl crystals.

  • Tungsten carbide vs. tungsten carbide – Ultimate abrasion resistance for high crystal loading (>15% solids).

Elastomers: Viton (FKM) – good low‑temperature flexibility down to -15°C; Aflas or Kalrez for superior chemical resistance.

Critical design note: The external flush (Plan 32) is essential. The flush fluid should be clean, compatible (e.g., warm water or clarified NH₄Cl solution), and injected at 1‑2 bar above pump suction pressure at a flow rate of 5‑15 L/min. The flush keeps solids out of the seal chamber and also prevents salt precipitation at the seal faces.

Crystallization Circuit Specific Design Features

  • Low NPSH – The pump takes suction from crystallizer vessels with limited driving head. A low‑NPSH impeller or inducer option is available.

  • Anti‑clogging impeller – Closed impeller with wide passages or semi‑open impeller to handle entrained crystals.

  • Jacketed stuffing box (optional) – To prevent salt crystallisation on the seal chamber at low ambient temperatures, a warm water jacket may be provided.

  • Material selection – All wetted parts in duplex or super duplex to resist chloride pitting and stress corrosion cracking.

Applications

IndustrySpecific Service
Soda ash (Hou`s / Union process) | Ammonium chloride crystallizer circulating pump; mother liquor cooling loop |
Chemical fertilizerNH₄Cl production and crystallisation
Chlor‑alkaliBrine circulation in crystallisers
Salt productionLow temperature crystallisation loops

Why Choose an API 610 OH1 Ammonium Chloride Crystallization Pump from This China Manufacturer

  • API 610 full compliance (OH1) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.

  • Duplex / super duplex materials – Superior resistance to high chloride pitting (PREN 35‑42), essential for NH₄Cl brine service.

  • Optimised for low temperature – Foot‑mounted design (OH1) sufficient for -5 to 25°C service, with proper elastomers for cold conditions.

  • Crystal‑handling capability – Wide internal passages, abrasion‑resistant seal faces, and Plan 32 external flush.

  • API 682 Plan 32 ready – External clean flush prolongs seal life dramatically in crystalline slurries.

  • Back pull‑out maintenance – Replace seals and wear rings without removing piping, minimising downtime.

  • Broad hydraulic coverage – Flows 50‑500 m³/h, heads 20‑60 m covering all crystalliser circulation duties.

  • Certified China manufacturer – API Q1, ISO 9001, with global references in soda ash and chemical industries.

  • Proven in NH₄Cl service – Thousands of OH1 pumps operating in ammonium chloride crystallization circuits worldwide.

Quality Assurance & Testing (Per API 610)

  • Hydrostatic test – Casing tested at 1.5× MAWP.

  • Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).

  • Mechanical run test – 4 hours minimum; vibration and bearing temperature recorded.

  • NPSH test – Optional, when specified.

  • Impeller dynamic balancing – Grade G6.3 or better.

  • Material certification – EN 10204 3.1 for pressure‑containing components; PMI available for alloy verification.

  • NDE – Dye penetrant on castings; ultrasonic on shafts as required.

  • Third‑party inspection – Available (DNV, Lloyds, BV, SGS).

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (Plan 32 ready, tungsten carbide faces)1 set
Wear ring set (casing + impeller)1 set
Bearing set (radial + thrust)1 set
Impeller (for critical duty)1 set
Shaft (for critical duty)1
Gasket / O‑ring kit (full set)1 set

Get a Quote or Engineering Support

For a detailed selection of the API 610 OH1 ammonium chloride crystallization circulation pump for your Hou`s process soda ash plant or NH₄Cl crystallizer loop – including flow, head, chloride concentration, crystallizer geometry, NPSHa, material selection (Duplex 2205 vs. Super Duplex 2507), and API 682 seal plan (Plan 32 with tungsten carbide) – please contact our engineering team.

Email: info@hyrig.com

*Our API 610 OH1 ammonium chloride crystallization circulation pumps are specifically engineered for the most corrosive, cold NH₄Cl brine service – handling >80,000 ppm Cl⁻ with entrained crystals. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with duplex/super duplex wetted parts, Plan 32 external flush, and back pull‑out design for easy maintenance.*


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit