The ammonium chloride crystallization circulation pump is a specialised centrifugal pump designed for circulating cold, high‑chloride brine in the ammonium chloride crystallization and separation circuit of soda ash production plants using Hou`s process (combined process / Union process). After carbonation and mother liquor treatment, the ammonium chloride (NH₄Cl) is crystallised from the mother liquor by cooling. The crystallization circuit requires circulation of the cold brine (‑5 to 25°C) containing high concentrations of ammonium chloride and sodium chloride, together with entrained NH₄Cl crystals, through crystallizers, cooling sections, and to centrifuges or filters for crystal separation.
This service is extremely challenging due to:
High chloride concentration (Cl⁻ > 80,000 ppm) – very corrosive, leading to pitting and crevice corrosion of standard stainless steels.
Low temperature (‑5 to 25°C) – thermal stress on materials; also risk of salt precipitation if temperature fluctuates.
Entrained crystals – fine NH₄Cl crystals can be abrasive and cause seal and wear ring wear.
Corrosive ammonia – the mother liquor contains free ammonia, which attacks copper alloys and some elastomers.
The pump is classified under API 610 (ISO 13709) as Type OH1 – an overhung, foot‑mounted, radially split, single‑stage centrifugal pump. The OH1 foot mounting is suitable for low‑to‑medium temperature service (‑5 to 25°C, well within the capacity of foot‑mounted pumps) and provides a robust, accessible design with back pull‑out for easy seal and impeller maintenance.
This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, extensive experience in corrosion‑resistant alloys, and thousands of OH1 pumps operating in ammonium chloride crystallization circuits worldwide.
| Feature | Description |
|---|---|
| API 610 Type | OH1 (overhung, foot‑mounted, radially split, single‑stage) |
| Casing form | Radially split volute, foot‑mounted |
| Bearing support | Overhung – impeller overhangs from bearing housing; bearings at drive end only |
| Number of stages | Single stage |
| Suction type | End suction, single‑suction |
| Discharge orientation | Top or side discharge (as required) |
| Flange rating | ANSI Class 150 / 300 (as required) |
| Compliance | API 610 11th / 12th edition (ISO 13709) |
Foot‑mounted simplicity – For low‑temperature service (‑5 to 25°C), centreline mounting is not required; foot‑mounting is sufficient and reduces cost while still meeting API 610 requirements.
Overhung design – Compact, easy to maintain, with back pull‑out capability.
Radially split casing – Provides good pressure containment and allows access to the rotor.
Back pull‑out design – The entire rotating assembly can be removed without disconnecting piping – essential for pumps that require frequent seal replacement due to abrasive crystals.
Single‑stage open passages – Wide internal flow paths allow entrained crystals to pass without clogging.
| Parameter | Design Range |
|---|---|
| Flow rate | 50 – 500 m³/h (220 – 2,200 GPM) |
| Head | 20 – 60 m (65 – 195 ft) |
| Fluid temperature | -5 to 25°C (23 to 77°F) |
| Fluid composition | Ammonium chloride (NH₄Cl) ‑ brine ~25‑28%, sodium chloride, free ammonia, fine NH₄Cl crystals |
| Chloride concentration | > 80,000 ppm (8%+), highly corrosive |
| Solids content | 5‑10% fine NH₄Cl crystals (entrained) |
| Specific gravity | 1.10 – 1.20 |
| pH | 7 – 9 (ammoniacal) |
| Maximum pressure | 1.5 – 2.5 MPa (15 – 25 bar) |
| Speed | 1,450 / 2,900 rpm (50Hz) or 1,750 / 3,500 rpm (60Hz) |
| NPSHr | Optimised (<3‑5 m) – inducer option for low NPSHa |
| Pump efficiency | 65‑78% (depending on size and crystal loading) |
| Design life | 20 years minimum |
Standard 316L stainless steel (S‑8) is not sufficient for prolonged exposure to chloride concentrations > 50,000 ppm, especially in the presence of crevices and low temperature. Higher alloys are required.
| Component | Recommended Material | API 610 Class | PREN Value |
|---|---|---|---|
| Casing | Duplex 2205 or Super Duplex 2507 | D‑1 / D‑2 | 35‑42 |
| Impeller | Duplex 2205 or Super Duplex 2507 | D‑1 / D‑2 | 35‑42 |
| Shaft | Duplex 2205 or Super Duplex | D‑1 / D‑2 | – |
| Wear rings | Duplex + Stellite / tungsten carbide | – | – |
| Seal chamber | Duplex or super austenitic (904L / 254 SMO) | – | – |
| Fasteners | Duplex or super duplex | – | – |
| Gaskets | PTFE or Viton (FKM) | – | – |
| Chloride concentration | Recommended material | PREN | Remarks |
|---|---|---|---|
| 20,000 – 50,000 ppm | 316L (S‑8) | 25‑30 | Marginal for long term, not recommended for NH₄Cl brine |
| 50,000 – 100,000 ppm | Duplex 2205 (D‑1) | 35‑38 | Standard choice for NH₄Cl crystallization |
| 100,000 – 150,000 ppm | Super Duplex 2507 (D‑2 / U‑8) | >40 | For high Cl⁻ and low pH conditions |
| Very high + risk of crevice | Super austenitic (904L, 254 SMO) | 35‑43 | Alternative to super duplex |
For ammonium chloride crystallization circuits, Duplex 2205 (API 610 Class D‑1) is the most cost‑effective and proven material. For particularly aggressive conditions or higher Cl⁻ concentrations, Super Duplex 2507 (Class D‑2/U‑8) is recommended.
All materials supplied with EN 10204 Type 3.1 certification and full traceability. NACE MR0175 is not typically required for this service (no H₂S), but can be provided on request.
The cold ammonium chloride brine contains fine NH₄Cl crystals that can abrade seal faces and cause seal failure. Additionally, the low temperature can cause elastomer hardening.
| Seal Arrangement | API 682 Plan | Suitability |
|---|---|---|
| Single seal with external clean flush | Plan 32 | Highly recommended – continuous injection of clean external fluid (warm water or clarified brine at 10‑20°C) flushes crystals away from seal faces |
| Dual pressurised (Arrangement 3) | Plan 53B | Zero emissions, but must be combined with Plan 32 or barrier fluid heating to avoid low‑temperature issues |
| Single seal with quench | Plan 62 | Not sufficient for crystalline slurries |
Silicon carbide vs. tungsten carbide – Tungsten carbide faces are very hard (>1,800 Hv) and resist abrasion from NH₄Cl crystals.
Tungsten carbide vs. tungsten carbide – Ultimate abrasion resistance for high crystal loading (>15% solids).
Elastomers: Viton (FKM) – good low‑temperature flexibility down to -15°C; Aflas or Kalrez for superior chemical resistance.
Critical design note: The external flush (Plan 32) is essential. The flush fluid should be clean, compatible (e.g., warm water or clarified NH₄Cl solution), and injected at 1‑2 bar above pump suction pressure at a flow rate of 5‑15 L/min. The flush keeps solids out of the seal chamber and also prevents salt precipitation at the seal faces.
Low NPSH – The pump takes suction from crystallizer vessels with limited driving head. A low‑NPSH impeller or inducer option is available.
Anti‑clogging impeller – Closed impeller with wide passages or semi‑open impeller to handle entrained crystals.
Jacketed stuffing box (optional) – To prevent salt crystallisation on the seal chamber at low ambient temperatures, a warm water jacket may be provided.
Material selection – All wetted parts in duplex or super duplex to resist chloride pitting and stress corrosion cracking.
| Industry | Specific Service |
|---|---|
| Soda ash (Hou`s / Union process) | Ammonium chloride crystallizer circulating pump; mother liquor cooling loop | | |
| Chemical fertilizer | NH₄Cl production and crystallisation |
| Chlor‑alkali | Brine circulation in crystallisers |
| Salt production | Low temperature crystallisation loops |
API 610 full compliance (OH1) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.
Duplex / super duplex materials – Superior resistance to high chloride pitting (PREN 35‑42), essential for NH₄Cl brine service.
Optimised for low temperature – Foot‑mounted design (OH1) sufficient for -5 to 25°C service, with proper elastomers for cold conditions.
Crystal‑handling capability – Wide internal passages, abrasion‑resistant seal faces, and Plan 32 external flush.
API 682 Plan 32 ready – External clean flush prolongs seal life dramatically in crystalline slurries.
Back pull‑out maintenance – Replace seals and wear rings without removing piping, minimising downtime.
Broad hydraulic coverage – Flows 50‑500 m³/h, heads 20‑60 m covering all crystalliser circulation duties.
Certified China manufacturer – API Q1, ISO 9001, with global references in soda ash and chemical industries.
Proven in NH₄Cl service – Thousands of OH1 pumps operating in ammonium chloride crystallization circuits worldwide.
Hydrostatic test – Casing tested at 1.5× MAWP.
Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).
Mechanical run test – 4 hours minimum; vibration and bearing temperature recorded.
NPSH test – Optional, when specified.
Impeller dynamic balancing – Grade G6.3 or better.
Material certification – EN 10204 3.1 for pressure‑containing components; PMI available for alloy verification.
NDE – Dye penetrant on castings; ultrasonic on shafts as required.
Third‑party inspection – Available (DNV, Lloyds, BV, SGS).
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (Plan 32 ready, tungsten carbide faces) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Bearing set (radial + thrust) | 1 set |
| Impeller (for critical duty) | 1 set |
| Shaft (for critical duty) | 1 |
| Gasket / O‑ring kit (full set) | 1 set |
For a detailed selection of the API 610 OH1 ammonium chloride crystallization circulation pump for your Hou`s process soda ash plant or NH₄Cl crystallizer loop – including flow, head, chloride concentration, crystallizer geometry, NPSHa, material selection (Duplex 2205 vs. Super Duplex 2507), and API 682 seal plan (Plan 32 with tungsten carbide) – please contact our engineering team.
Email: info@hyrig.com
*Our API 610 OH1 ammonium chloride crystallization circulation pumps are specifically engineered for the most corrosive, cold NH₄Cl brine service – handling >80,000 ppm Cl⁻ with entrained crystals. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with duplex/super duplex wetted parts, Plan 32 external flush, and back pull‑out design for easy maintenance.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.