API 610 Pump Selection Overview for Soda Ash Industry – Standard Configurations

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 pump selection guide for soda ash production (Hou`s process / Solvay process). Covers all standard pump types: OH1/OH2 overhung pumps for 80% of routine duties (mother liquor, ammonia brine, cleaning liquid); BB1 between-bearings axial split for high flow low head main circulation; BB2 radially split for high pressure crystallization and transfer; BB3 multistage for boiler feed and high pressure process water; VS4/VS5 vertical sump for mother liquor tanks, underground pits, emergency spills; VS2 vertical turbine for deep well raw water, seawater lift, and condensate recovery. API 610 11th/12th edition compliant. 20-year design life, 3-year continuous operation.

Conatct For Details
DetailReview(0)Additional

Introduction

In soda ash production (Hou`s combined process / ammonia-soda / Solvay process), selecting the correct API 610 pump type for each service is critical for reliability, energy efficiency, and long-term operation. This overview summarizes the standard pump configurations used across the plant – from ammonia brine preparation to crystallization, mother liquor handling, boiler feed, and utility services.

All pumps comply with API 610 11th/12th edition (ISO 13709) , offering 20‑year design life and minimum 3‑year uninterrupted operation. The following table presents the standard API 610 types for each major service.


API 610 Pump Type Selection Matrix for Soda Ash Industry

Pump TypeAPI 610 ClassTypical Service in Soda Ash PlantFlowHeadKey FeaturesMaterial Recommendation
OH1 / OH2OH1 (foot‑mounted), OH2 (centreline‑mounted)Mother liquor circulation, ammonia brine transfer, cleaning liquid pump, absorber feed/reflux, heat recovery circulation, filter feedLow‑MediumLow‑MediumMost common type (covers ~80% of process duties). Back pull‑out design. OH2 for hot service (>80°C). Single‑stage overhung.316L SS (S‑8) or duplex for high Cl⁻; cast iron + bronze for clean water
BB1BB1 (axial split, between‑bearings, single‑stage)Large ammonia brine main circulation pump, cooling water circulation, reboiler circulationHigh (500‑5,000 m³/h)Low‑Medium (25‑100 m)High flow, low head. Axially split casing allows rotor access without removing piping. Between‑bearings for high rigidity. Single‑stage.316L SS (S‑8) or duplex (D‑1) for ammonia brine; cast iron for clean water
BB2BB2 (radially split, between‑bearings, single‑/two‑stage)NH₄Cl crystallizer circulation pump, high pressure mother liquor transfer, salting‑out feed pumpMedium‑High (50‑1,000 m³/h)Medium‑High (100‑400 m)Radially split barrel casing provides high pressure containment. Between‑bearings for stability. Ideal for high pressure crystallizer loops.Duplex (D‑1) or super duplex (D‑2) for NH₄Cl brine; 316L SS for less aggressive
BB3BB3 (axial split, between‑bearings, multistage)Boiler feed pump (BFW), high pressure process water pump, RO feedMedium‑High (10‑1,500 m³/h)High (300‑1,500 m)Multistage (3‑14 stages). Axially split casing. Opposed impellers for axial thrust balance. Double volute for radial balance. Centreline‑mounted for high temperature.Carbon steel casing + stainless steel internals (S‑8) for process water; carbon steel for boiler feed
VS4 / VS5VS4 (wet pit sump), VS5 (closed sump/barrel)Mother liquor tank sump, underground tank pump, emergency pit pumpLow‑Medium (10‑400 m³/h)Low‑Medium (15‑60 m)Vertically suspended, submerged suction – no priming required. Excellent low NPSH. VS4 for open pits; VS5 for closed tanks with suction pipe.316L SS (S‑8) for corrosive mother liquor; carbon steel + SS internals for clean water
VS2VS2 (vertical turbine, wet pit)Raw water deep well pump, seawater lift pump, condensate recovery pumpMedium‑High (20‑10,000 m³/h)Low‑Medium (15‑200 m)Vertical turbine, surface‑mounted motor, submerged bowl. Ideal for deep wells, low NPSH hot condensate, and seawater intake. Single‑ or multistage.316L SS (S‑8) or duplex / super duplex for seawater; carbon steel + SS for fresh water / condensate

Detailed Description by Pump Type

OH1 / OH2 – Overhung Process Pumps (80% of Routine Duties)

Application: Mother liquor circulation, ammonia brine transfer, cleaning liquid pump, absorber feed/reflux, heat recovery circulation, calciner feed pump, heavy soda filtrate pump.

Why OH1/OH2: These overhung, single‑stage, end‑suction centrifugal pumps are the workhorses of the soda ash plant. They cover most medium‑flow, medium‑head duties. The back pull‑out design allows seal and impeller replacement without removing piping – minimizing downtime. OH1 (foot‑mounted) is used for moderate temperature (<80°C); OH2 (centreline‑mounted) is recommended for hot service (>80°C) to accommodate thermal expansion.

Hydraulic range: Flow 10‑600 m³/h, head 10‑150 m (OH2 up to 260 m).

Materials: 316L stainless steel (S‑8) for corrosive mother liquor and ammonia brine; duplex (D‑1) for high chloride; cast iron + bronze for cleaning water loops.


BB1 – High Flow, Low Head Main Circulation

Application: Large ammonia brine main circulation pump (from storage to carbonating towers), cooling water circulation, reboiler circulation.

Why BB1: The BB1 is an axially split, between‑bearings, single‑stage pump designed for very high flow rates (500‑5,000 m³/h) at moderate heads. The between‑bearings rotor provides exceptional rigidity and low vibration at high flow. The axially split casing allows the upper half to be removed without disturbing suction/discharge piping – giving full access to the impeller and wear rings. Single‑stage design is simple and robust, handling suspended solids without clogging.

Hydraulic range: Flow 500‑5,000 m³/h, head 25‑100 m.

Materials: 316L SS or duplex (D‑1/D‑2) for ammonia brine; cast iron for clean cooling water.


BB2 – High Pressure Crystallizer & Transfer Pumps

Application: NH₄Cl crystallizer circulation pump, high pressure mother liquor transfer to ammonia recovery, salting‑out feed pump.

Why BB2: The BB2 is a radially split (barrel), between‑bearings, single‑stage or two‑stage pump. The radial split casing provides superior pressure containment (up to 300 bar), making it ideal for high pressure crystallization loops and long‑distance high‑head transfer. Between‑bearings support ensures rotor stability under high differential pressure. Single‑stage design handles entrained NH₄Cl crystals without clogging interstage passages.

Hydraulic range: Flow 50‑1,000 m³/h, head 100‑400 m (up to 1,500 m with multistage variants).

Materials: Duplex 2205 (D‑1) or super duplex 2507 (D‑2) for high chloride NH₄Cl brine; 316L SS for less aggressive mother liquor.


BB3 – Multistage High Pressure Boiler Feed & Process Water

Application: Boiler feed pump (BFW), high pressure process water pump, reverse osmosis feed, high pressure wash water.

Why BB3: The BB3 is an axially split, between‑bearings, multistage (3‑14 stages) pump. It generates high heads (up to 1,500 m) from a compact footprint. Opposed back‑to‑back impellers provide hydraulic axial thrust self‑balance – eliminating balance discs or drums. Double volute casing balances radial thrust. Axially split casing allows full rotor access without removing piping. Centreline mounting accommodates thermal expansion at high temperatures (up to 205°C). First‑stage double‑suction impeller option for low NPSH.

Hydraulic range: Flow 10‑1,500 m³/h, head 100‑1,500 m (300‑600 m typical for boiler feed).

Materials: Carbon steel casing (C‑6) with stainless steel 304/316L internals for process water; carbon steel for clean boiler feed water.


VS4 / VS5 – Vertical Sump Pumps for Tanks & Pits

Application: Mother liquor tank sump, underground tank pump, emergency pit pump, spill collection.

Why VS4/VS5: These vertically suspended, wet pit, single‑casing pumps are designed for collecting corrosive mother liquor from low‑level tanks, underground pits, and emergency sumps. The pump bowl is submerged, so no priming is required – essential for intermittent service. Excellent low NPSH performance (submerged impeller). VS4 (open suction) is used for wet pits; VS5 (closed suction/barrel) for sealed tanks or when suction pipe is required. The rotating assembly is withdrawable upward without draining the pit.

Hydraulic range: Flow 10‑400 m³/h, head 15‑60 m.

Materials: 316L stainless steel (S‑8) for corrosive mother liquor; carbon steel + stainless steel trim for less aggressive water.


VS2 – Vertical Turbine for Deep Well & Condensate

Application: Raw water deep well pump, seawater lift pump, condensate recovery pump from low‑level pits.

Why VS2: The VS2 is a vertical turbine, wet pit, single‑casing pump with a surface‑mounted driver. The bowl assembly is submerged, providing excellent low NPSH for hot condensate or deep well applications. The vertical design saves floor space and eliminates priming. The pump can be single‑stage or multistage (for higher heads). Flexible line shaft with intermediate sleeve bearings supports long setting depths (up to 50 m). Suitable for seawater intake, groundwater extraction, and high‑temperature condensate return (up to 200°C).

Hydraulic range: Flow 20‑10,000 m³/h, head 15‑200 m.

Materials: 316L SS (S‑8) or duplex/super duplex for seawater; carbon steel + SS internals for fresh water and condensate.


Summary of Standard Configurations

Pump TypeApplication SummaryFlowHeadMaterial Class
OH1/OH280% of process duties: mother liquor, ammonia brine, cleaning, reflux, heat recovery10‑600 m³/h10‑260 m316L SS (S‑8) / duplex (D‑1)
BB1High flow low head: ammonia brine main circulation, cooling water500‑5,000 m³/h25‑100 m316L SS / duplex / cast iron
BB2High pressure: NH₄Cl crystallizer, mother liquor high head transfer50‑1,000 m³/h100‑400 mDuplex (D‑1/D‑2)
BB3Multistage high pressure: boiler feed, high pressure process water10‑1,500 m³/h100‑1,500 mCarbon steel + 316L internals
VS4/VS5Sump & pits: mother liquor tanks, underground tanks, emergency pits10‑400 m³/h15‑60 m316L SS (S‑8)
VS2Deep well / seawater / condensate: raw water wells, seawater lift, condensate recovery20‑10,000 m³/h15‑200 m316L SS / duplex / super duplex

Why Choose Our API 610 Pumps for Soda Ash Industry

  • Full API 610 compliance – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.

  • Proven in soda ash – Thousands of pumps installed in Hou`s process and Solvay plants worldwide.

  • Complete range – From OH1/OH2 process pumps to BB1 main circulation, BB2 high pressure, BB3 multistage, VS4/VS5 sump pumps, and VS2 deep well/condensate pumps.

  • Corrosion resistance – 316L SS, duplex, and super duplex materials for high chloride ammonia brine and NH₄Cl service.

  • Low NPSH options – Inducers, double‑suction first stages, submerged vertical designs for low NPSHa applications.

  • API 682 mechanical seals – Plan 32 (external flush), Plan 23 (cooled recirculation), Plan 53B (dual pressurised) for sealing hot, abrasive, and hazardous fluids.

  • Back pull‑out / axial split / withdrawable designs – Easy maintenance without disturbing piping.

  • Certified manufacturer – API Q1, ISO 9001, with global references.

Get a Quote or Engineering Support

For detailed pump selection for your soda ash project – including process conditions, flow/head requirements, fluid composition, material selection, and API 610 pump type recommendation – please contact our engineering team.

Email: info@hyrig.com

*Our API 610 pump selection guide for soda ash industry covers all standard configurations from OH1/OH2 for routine duties, BB1 for high flow, BB2 for high pressure, BB3 for multistage high head, VS4/VS5 for sump, and VS2 for deep well and condensate – ensuring reliable, long‑life operation across your entire plant.*


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit