Every vertical barrel pump undergoes the following tests as a minimum.
Casing (outer barrel): 1.5× maximum allowable working pressure (MAWP)
Hold time: 30 minutes minimum
Acceptance: No visible leakage or pressure drop
Grade: API 610 Grade 2 (Grade 1 optional)
Fluid: Water at rated speed (or test speed)
Points: Shut‑off, 25%, 50%, 75%, 90%, 100%, 110% of BEP flow
Measured: Head, flow, power, efficiency, NPSHr
Tolerance: Per API 610 Table 24
Method: Constant flow, reduce suction pressure until 3% head drop
Report: NPSHr curve at rated speed
Duration: 4 hours minimum at rated speed (or maximum continuous speed)
Monitor: Bearing temperature (rise ≤40°C), vibration velocity (≤3 mm/s rms)
Record: Discharge pressure, power, ambient conditions
| Component | NDE method | Acceptance criteria |
|---|---|---|
| Outer barrel (forging) | Ultrasonic (UT) | No flaws >1.5 mm equivalent |
| Shaft | Ultrasonic (UT) + Magnetic Particle (MT) | API 610 / ASME Section VIII |
| Impeller (cast) | Dye Penetrant (PT) or Radiography (RT) | No surface cracks |
| Weld joints (barrel to flange) | Radiography (RT) or UT | Full penetration, no defects |
Standard: EN 10204 Type 3.1 – full chemical and mechanical test reports, traceable to heat number.
Optional: EN 10204 Type 3.2 (third‑party inspection by Lloyds, DNV, BV, etc.)
Positive Material Identification (PMI) – Available for alloy verification (e.g., 316L, duplex, 9% Ni).
We welcome customer or third‑party witnesses for all tests. Typical inspection bodies:
Lloyds Register
DNV
Bureau Veritas
SGS
TÜV
Each pump is supplied with:
Certified performance curve (including NPSH curve when tested)
Hydrostatic test certificate
Material certificates (EN 10204 3.1)
Dimensional outline drawing
Cross‑sectional drawing
Instruction & maintenance manual
Mechanical seal data sheet (API 682)
For any inquiries, please contact: info@hyrig.com