Before first start:
Ensure outer barrel is flooded – vent air through top vents. No air pockets near first‑stage impeller.
Check thrust bearing lift – on Kingsbury tilting‑pad bearings, manually jack the rotor to ensure correct lift height (0.1‑0.3 mm typical).
Purge balance line – the line from the balance drum back to suction must be free of debris.
Prime mechanical seal – if Plan 23 or 53B, ensure barrier fluid is filled and pressurised.
Motor rotation check – bump motor, confirm correct direction (arrow on pump casing).
Partially open discharge valve (10‑20%).
Start motor.
Monitor discharge pressure – should rise quickly.
Slowly open discharge valve to operating point.
Check:
Bearing temperature – stable within 40°C rise above ambient.
Vibration – ≤3 mm/s rms.
Seal flush flow (Plan 11/21/23) – visual indicator.
| Task | Frequency |
|---|---|
| Check discharge pressure & flow vs. curve | Monthly |
| Monitor vibration trend (plot per month) | Monthly |
| Inspect seal barrier fluid level (Plan 53B) | Weekly |
| Check bearing oil level (if oil bath) | Weekly |
| Sample oil for moisture (thrust bearing) | Annually |
Isolate and drain pump.
Disconnect driver coupling.
Remove discharge head cover (if separate).
Unbolt the cartridge flange from the discharge head.
Lift the entire inner assembly (shaft, impellers, diffusers, radial bearings) vertically out of the outer barrel.
Place on workbench for disassembly – clean and measure:
Impeller to diffuser clearances
Balance drum gap
Radial bearing clearances
Wear ring clearances
Reassemble – reverse order. Use new gaskets and O‑rings.
For many VS6 pumps, the seal is accessible from above after removing the driver and top cover. Follow API 682 seal manufacturer’s instructions.
| Problem | Likely cause | Remedy |
|---|---|---|
| Pump trips on overcurrent | Rotor stuck, fluid density too high, balance line blocked | Rotate shaft by hand; check fluid properties; clean balance line |
| Excessive vibration | Impeller imbalance, misalignment, cavitation, bearing wear | Balance assembly; re‑align driver; check NPSHa; replace bearing |
| Low discharge pressure | Worn wear rings / balance drum, air in suction, inlet strainer blocked | Replace wear parts; vent casing; clean strainer |
| High thrust bearing temperature | Wrong oil level, excessive axial thrust (balance device worn) | Adjust oil; check balance drum clearance |
| Seal leaks (Plan 53B pressure drop) | Worn seal faces, barrier fluid loss | Replace cartridge; refill barrier fluid |
Drain completely, dry with hot air.
Apply rust preventive (VCI paper or fogging oil).
Fill outer barrel with nitrogen blanket (for cryogenic pumps).
Rotate shaft monthly to prevent bearing brinelling.
For any inquiries, please contact: info@hyrig.com