Cryogenic liquids (LNG at -162°C, LOX at -183°C, LN₂ at -196°C) have extremely low boiling points and are stored at near‑atmospheric pressure. Pumping these fluids presents unique challenges: standard centrifugal pumps would cavitate instantly because the liquid is at its boiling point. The pump must maintain positive Net Positive Suction Head available above the vapour pressure – otherwise explosive vaporisation occurs.
The cryogenic pump is a vertically suspended, double‑casing diffuser pump (API 610 Type VS6) with the motor and pump integrated into a single sealed unit, fully submerged in the cryogenic liquid.
Operating cycle:
The pump motor and impeller are completely immersed in the cryogenic liquid, which provides continuous cooling and eliminates priming requirements.
The integrated inducer at the suction inlet forces liquid into the first‑stage impeller, dramatically reducing NPSHr.
Multistage diffuser vanes surrounding each impeller convert velocity to pressure – total head is the sum of each stage.
The liquid is discharged through a column pipe to the vaporiser or tank outlet.
Because the motor is submerged, no shaft penetrates the tank wall – only stationary electrical connections. This eliminates dynamic seals and provides absolute zero leakage.
Submerged motor – No shaft seal, no mechanical dynamic seal. The motor windings are cooled directly by the cryogenic liquid.
Double‑casing (can type) – Outer barrel contains pressure; inner assembly withdraws for maintenance.
Inducer – Axial flow stage before first radial impeller, reduces NPSHr by 40‑60%.
Diffuser hydraulics – High efficiency (up to 80.2%) and lower radial loads at off‑design conditions.