Coffer dam system – Install coffer dam / purge mechanism to isolate pump from tank when removing inner assembly.
Cool‑down procedure – Slowly introduce cryogenic liquid at controlled rate (≤5°C/min) to avoid thermal shock. Monitor differential expansion.
Motor insulation test – Measure insulation resistance before initial start. Cryogenic exposure can affect insulation.
Venting – Ensure all trapped gas is vented before impeller rotation. Vapour pockets cause dry running.
Ensure the suction can is fully flooded – the pump must be submerged below the minimum operating liquid level.
Start motor – unit should reach operating speed within 5‑10 seconds.
Monitor:
Discharge pressure – stabilises at design value.
Motor current – steady within 10% of nameplate.
Vibration (if monitored) – ≤3 mm/s rms.
Temperature sensors – in winding and bearings.
Because the pump has no mechanical shaft seal, traditional seal replacement is eliminated. Maintenance focuses on:
| Component | Task | Frequency |
|---|---|---|
| Motor winding insulation | Monitor resistance | Monthly |
| Vibration trend | Compare to baseline | Weekly |
| Vapour return line | Inspect for blockage | Quarterly |
| Thrust bearing oil (oil‑lubricated) | Check level and condition | Monthly |
Isolate pump from tank – close valves, activate coffer dam.
Allow pump to warm to ambient temperature – purge with dry nitrogen.
Disconnect electrical leads at tank penetration.
Unbolt discharge head flange.
Lift the entire cartridge (motor + impeller stack + diffusers) vertically out of the outer barrel.
On workbench: inspect impeller clearance, diffuser wear, bearing condition.
Clean, measure clearances, replace worn parts.
Reassemble – reverse order. Replace all static seals (O‑rings) and gaskets.
| Problem | Likely cause | Remedy |
|---|---|---|
| Pump fails to start | Low liquid level, vapour lock, electrical fault | Ensure flooded, vent vapour, check power supply |
| Low flow / low discharge pressure | Worn impeller, inducer damage, gas ingestion | Pull pump; inspect; replace damaged components |
| Excessive vibration | Rotor imbalance, bearing wear, cavitation | Balance rotor; check bearing clearance; increase NPSHa (inducer check) |
| Overcurrent (motor trips) | Dense liquid (two‑phase), tight bearings, voltage drop | Check fluid quality; run cool‑down cycle; verify supply |
| Temperature alarm (winding/bearings) | Prolonged dry running, blocked cooling passages | Ensure submergence; inspect internal cooling channels |
Drain completely, purge with dry nitrogen to remove moisture.
Apply rust preventive on accessible machined surfaces.
Store vertically in dry, covered area.
Rotate shaft (if accessible) monthly to prevent bearing brinelling.