Four VS2 pump successful cases. Case 1: Refinery hydrocracking feed – API 610 VS2 can-type pump for hydrocracking unit feed, ultra low NPSH no cavitation, long-term stable operation. Case 2: Petrochemical reactor feed – duplex material VS2 pump for corrosive process medium, high pressure resistance and leak-free running. Case 3: Power plant condensate boosting – custom stage VS2 pump for condensate high-head pressurization, high efficiency, low vibration. Case 4: Low NPSH chemical process – VS2 can-type design solved insufficient NPSH problem, perfectly matched process design requirements. Can-type flooded suction eliminates cavitation. Multistage up to 1500 m head. We provide installation drawings, site photos, and project performance data.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 VS2 vertical can-type multistage pumps operating reliably in extremely low NPSH, high head critical services. Each case demonstrates the pump's ability to eliminate cavitation, handle high pressure, and deliver long-term stable performance in refinery, petrochemical, power, and chemical applications.


Case 1 – Refinery Hydrocracking Feed (Middle East)

Background: A refinery required a high-pressure feed pump for a hydrocracking unit. The feedstock was light hydrocarbon at near-boiling temperature, with available NPSH less than 2.5 meters. Horizontal multistage pumps experienced severe cavitation and seal failures.

VS2 Pump Solution:

  • Flow: 320 m³/h

  • Head: 1,350 m

  • Temperature: 210°C

  • Can length: 3,600 mm

  • Material: Alloy steel can, 316L impellers

  • Stages: 9

Results:

  • Ultra low NPSH – can-type flooded suction eliminated cavitation completely

  • Long-term stable operation – over 3 years without pump-related downtime

  • No suction piping – reduced leak points and installation complexity

  • Cartridge rotor – annual inspection completed without removing can casing

Available references: Can installation drawing, site photo, NPSH calculation sheet.


Case 2 – Petrochemical Reactor Feed (Southeast Asia)

Background: A petrochemical plant needed a high-pressure pump for feeding a polymerization reactor with corrosive process medium (chlorinated solvent). Required head: 1,100 m. Available NPSH was limited. Standard 316L showed pitting after short service.

VS2 Pump Solution:

  • Flow: 180 m³/h

  • Head: 1,100 m

  • Temperature: 120°C

  • Can length: 2,800 mm

  • Material: Duplex stainless steel (can, impeller, shaft)

  • Stages: 8

  • Seal: API 682 Plan 53B dual mechanical seal

Results:

  • Duplex material – withstood corrosive medium for 2+ years without pitting

  • High pressure resistance – 110 bar discharge pressure maintained consistently

  • Leak-free running – dual seal with barrier fluid achieved zero emissions

  • Stable operation – no cavitation despite low NPSH

Available references: Material certificate (EN 10204 3.1), installation photo, seal performance log.


Case 3 – Power Plant Condensate Boosting (Asia)

Background: A combined cycle power plant required a condensate booster pump to transfer hot condensate (85°C) from a low-level hotwell to the deaerator. The condensate was near boiling point, and horizontal pumps cavitated frequently, causing plant trips.

VS2 Pump Solution:

  • Flow: 280 m³/h

  • Head: 520 m

  • Temperature: 85°C

  • Can length: 3,200 mm

  • Material: Carbon steel can, stainless steel impellers

  • Stages: 5 (custom stage count for exact head)

Results:

  • High efficiency (82%) – better than previous multistage horizontal pump

  • Low vibration – vertical can design absorbed thermal expansion, vibration <2.0 mm/s

  • No cavitation – can-type flooded suction eliminated NPSH problem

  • 24/7 continuous operation – 18 months without failure

Available references: Performance test report, vibration log, site photo.


Case 4 – Low NPSH Chemical Process (Europe)

Background: A chemical facility had a process requiring high-head transfer (450 m) of a solvent with very low vapor pressure margin. Available NPSH was only 1.8 meters. Existing pumps cavitated severely, damaging impellers and seals within weeks.

VS2 Pump Solution:

  • Flow: 95 m³/h

  • Head: 450 m

  • Temperature: 60°C

  • Can length: 2,400 mm

  • Material: 316L stainless steel

  • Stages: 4

Results:

  • Solved insufficient NPSH problem – can-type design provided flooded suction, complete cavitation elimination

  • Perfectly matched process design requirements – achieved exact head and flow

  • Low maintenance – after 18 months, impeller and wear rings showed minimal wear

  • Simple installation – tank-top mounted, no foundation, no suction piping

Available references: Installation drawing, site photo, before/after cavitation comparison.


What You Can Request From Us for Each Case

  • Can installation drawings (2D CAD)

  • Site photos and tank mounting images

  • Project parameter sheet (flow, head, stages, can length, material)

  • Performance test data and NPSH calculations

Why Real Project Cases Matter

Field references prove that our VS2 pumps deliver:

  • No cavitation in ultra-low NPSH refinery hydrocracker feed service

  • Corrosion resistance and leak-free operation in petrochemical reactor feed (duplex)

  • High efficiency, low vibration in power plant condensate boosting

  • Perfect solution for insufficient NPSH chemical processes

Get the Complete VS2 Pump Case Study Package

We can match your low NPSH high head conditions to similar successful installations. Request the VS2 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery / petrochemical / power / chemical) and we will send relevant case studies, installation drawings, and technical data within 24 hours. We also welcome inquiries for custom VS2 vertical can-type multistage pump selection and factory direct pricing.