A can type pump (also called submersible cryogenic pump or in‑tank cryogenic pump) is designed to be fully immersed in cryogenic liquids such as LNG, liquid nitrogen, liquid oxygen, or liquid hydrogen. The pump is installed inside a pressure vessel (tank or cold box) with the motor and hydraulics submerged in the cold liquid. Our API 610 VS6 vertical, double‑casing, submerged can pump is specifically engineered for safe, zero‑leakage cryogenic service. This design fully complies with API 610 11th/12th edition (ISO 13709) .
Structure match check: API 610 VS6 is defined as a vertical, double‑casing, can pump with submerged driver (wet motor), designed for cryogenic or volatile liquids. This matches can type pump requirements because:
The pump has an outer can (barrel) that is pressure‑containing and insulated, and an inner casing (diffuser/impeller assembly) that handles the hydraulic duty.
The motor is directly coupled and fully submerged in the pumped cryogenic liquid, eliminating any shaft seal to atmosphere (zero leakage).
The assembly is suspended from a top flange, allowing easy withdrawal for maintenance.
This VS6 type is specifically intended for low temperature, low NPSH, and high‑pressure differential services typical of LNG, LN₂, and LH₂ pumping.
Why API 610 VS6 for can type cryogenic duty?
Zero leakage – No mechanical shaft seal. The motor is encapsulated or open to the cryogenic liquid, but the electrical windings are protected. No dynamic seal to the environment, eliminating fugitive emissions – critical for flammable and cryogenic fluids.
Low NPSH – The submerged first‑stage impeller or inducer provides extremely low NPSHr, often less than 1 meter, essential for pumping boiling liquids (LNG at -162°C, near saturation).
Double‑casing safety – Outer can (barrel) contains the full tank pressure and any potential leakage from the inner stage. The annulus between can and inner casing acts as a chill and safety volume.
High head capability – Multistage design (up to 10+ stages) achieves heads up to 1500 meters, suitable for LNG pipeline or transfer to high pressure vaporisers.
Easy maintenance – Entire pump (motor + stages + can) can be lifted out through the tank top nozzle without emptying the storage tank.
Wide flow range – 5 to 1000+ m³/h, covering LNG ship offloading, receiving terminals, peak‑shaving plants, and hydrogen refueling stations.
Key design features for can type cryogenic service
Outer can (barrel) – High‑strength stainless steel (316L / 304L) or 9% nickel steel. Designed for full tank pressure (up to 25 bar or more). Provides secondary containment.
Inner casing – Diffuser style, multiple stages (radial or mixed flow). Made of low‑temperature stainless steel or aluminum alloys.
Inducer / first‑stage impeller – High‑suction specific speed design to minimize NPSHr. Prevents cavitation (cryogenic liquids flash easily).
Submerged motor – Permanent magnet synchronous motor (PMSM) or induction motor. Wound with cryogenic‑resistant insulation. Rotor and stator cooled by the pumped liquid. No cooling jackets or external lubrication.
Bearings – Cryogenic‑compatible materials: PTFE‑composite, carbon graphite, or ceramic hybrid. Lubricated by the cryogenic fluid itself.
Sealing – No dynamic seal to atmosphere. The only seals are static O‑rings (metal C‑rings or elastomer compatible with cryogenic temperatures) at flanges and electrical feedthroughs.
Electrical connections – Hermetically sealed through the top flange, with appropriate cold‑shock resistant cable entry.
Materials – All wetted parts: 316L / 304L stainless steel, nickel‑based alloys (Inconel 718 for shafts), or A356‑T6 aluminum for impellers. Low temperature toughness tested per applicable codes (ASME, EN 13458).
NPSH – Ultra low NPSHr, typically <1 m, achieved by inducer and submerged configuration.
Typical performance range (LNG / liquid methane service)
| Parameter | Value |
|---|---|
| Flow rate | 5 – 1500 m³/h |
| Head | Up to 1500 m |
| Discharge pressure | Up to 150 bar (multistage) |
| Temperature | -253°C (LH₂) to -162°C (LNG) |
| Speeds | 1500 – 6000 rpm (VFD common) |
| Stages | 1 – 12 (depending on head) |
Typical applications
LNG receiving terminals – In‑tank pumps for offloading and send‑out.
LNG peak‑shaving plants – Transfer to vaporisers.
LNG fuelling stations (marine or truck) – High pressure fuel supply.
Liquid nitrogen / oxygen / argon – Air separation unit storage.
Liquid hydrogen – Refuelling stations and transport.
Marine fuel gas supply systems (FGSS) – Cryogenic pumps for LNG‑fuelled vessels.
Why choose our API 610 VS6 can type cryogenic pump?
Full API 610 compliance – Type VS6 verified. Cryogenic performance test (with suitable test medium) and mechanical run test.
Zero leakage design – No shaft seal, no packing, no dynamic emissions – meets the strictest environmental standards.
Ultra low NPSH – Reliable operation at or near boiling point, no cavitation.
Proven cryogenic materials – Alloys with full low‑temperature Charpy V‑notch testing.
Short lead time – Standard sizes (4‑10 inch discharge) available 24‑32 weeks.
Global spare parts support – Motors, impellers, diffusers, can assemblies, bearings, electrical penetrations shipped worldwide.
Quality assurance
ISO 9001:2015 certified.
API 610 mechanical run test with vibration and temperature monitoring (simulated using liquid nitrogen or clean cold water with safety).
NPSH test verification per API 610.
Hydrostatic test of outer can (1.5× design pressure) at cryogenic temperature design.
Material testing – Impact tests at service temperature (e.g., -196°C for LN₂).
PMI (positive material identification) for all alloys.
How to specify your can type cryogenic pump
Please provide: flow (m³/h), head (m), cryogenic fluid (LNG, LN₂, LH₂, LAr, LOX), operating temperature (°C), tank pressure (bar), NPSHa available (m), required material (316L / 9% Ni / aluminum), and driver type (VFD fixed speed). We will recommend number of stages, inducer design, motor type (PMSM), can diameter, and top flange details.
Contact us
For a quotation or technical discussion on can type cryogenic pumps (API 610 VS6) :
info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.