Circulating Cooling Water Pump – API 610 OH1 / OH2 Overhung Centrifugal Pump by Leading China 610 Pump Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 OH1/OH2 circulating cooling water pump – horizontal, overhung, single‑stage centrifugal pump engineered for continuous duty in industrial cooling water systems, HVAC condenser loops, power plant auxiliary cooling, and process cooling circuits. Available in OH1 foot‑mounted (moderate temperature) and OH2 centreline‑mounted (higher temperature) configurations. Cast iron or 316L stainless steel wetted parts. Flows to 1,000 m³/h, heads to 100 m, temperatures to 120°C. Back pull‑out design, API 682 mechanical seals with Plan 11. Manufactured by a leading certified China API 610 pump manufacturer with API Q1 certification. Flows 10‑1,000 m³/h, heads 10‑100 m. 20‑year design life, 3‑year continuous operation.

Conatct For Details
DetailReview(0)Additional

Product Overview

A circulating cooling water pump is a single‑stage, overhung centrifugal pump designed to move large volumes of cooling water through condensers, heat exchangers, cooling towers, and other cooling equipment in industrial plants, power stations, HVAC systems, and chemical facilities. Unlike high‑head multistage pumps, cooling water circulation typically requires moderate head (10‑100 metres) but high flow rates (10‑1,000 m³/h). The pump runs continuously, often 24/7, with minimal flow variation, demanding high reliability, long service life, and easy maintenance.

The pump is classified under API 610 (ISO 13709) as Type OH1 (foot‑mounted) or OH2 (centreline‑mounted). The OH1 foot‑mounted configuration is suitable for moderate temperature cooling water (≤80°C). The OH2 centreline‑mounted configuration is preferred for higher temperature water (≤120°C) or when thermal expansion could cause misalignment. Both types are overhung, radially split, single‑stage, end‑suction centrifugal pumps with back pull‑out design.

This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, decades of severe‑duty pumping experience, and thousands of OH1/OH2 units installed in cooling water services worldwide.

OH1 vs. OH2 Configuration for Cooling Water

FeatureOH1 (Foot‑mounted)OH2 (Centreline‑mounted)
MountingFeet on casing bottom bolted to baseplateFeet on casing centreline bolted to baseplate
Thermal expansionCasing expands downward; minor shaft riseCasing expands uniformly around centreline; shaft alignment maintained
Temperature rangeUp to 80°C (176°F)Up to 120°C (248°F) and higher
Best forAmbient to warm cooling water (cooling tower discharge, river water)Hot cooling water (condenser discharge, hot process cooling)
CasingRadially split voluteRadially split volute with centreline feet
API 610 TypeOH1OH2

Which one to choose?

  • Use OH1 when cooling water temperature is below 80°C, typically from cooling towers, rivers, lakes, or ambient sources. Foot‑mounted pumps are simpler and more cost‑effective.

  • Use OH2 when cooling water temperature exceeds 80°C, such as direct discharge from condensers or heat exchangers where water is 80‑120°C. The centreline mounting prevents misalignment caused by thermal expansion of the casing.

Construction & API 610 Classification (Common to OH1 and OH2)

FeatureDescription
API 610 TypeOH1 (foot‑mounted) or OH2 (centreline‑mounted)
Casing formRadially split, single volute (or double volute for large sizes)
Bearing supportOverhung – impeller overhangs from bearing housing; bearings at drive end
Number of stagesSingle stage
Suction typeEnd suction, single‑suction
Discharge orientationTop or vertical discharge (standard)
MountingOH1: foot‑mounted / OH2: centreline‑mounted
Flange ratingANSI Class 150 / 300 (standard for cooling water pressures)
ComplianceAPI 610 11th / 12th edition (ISO 13709)

Back pull‑out design – The complete rotating assembly (impeller, shaft, bearing housing, mechanical seal) can be removed without disturbing suction or discharge piping. This is essential for cooling water pumps that may require seal or impeller inspection after long operating periods.

Heavy‑duty bearing housing – Finned or water‑cooled (optional) to dissipate heat. L10 bearing life ≥25,000 hours per API 610. Oil lubrication standard.

Impeller – Closed (enclosed) radial type for high efficiency. Dynamically balanced. Standard material: cast iron, bronze, 304 SS, or 316L SS.

Wear rings – Replaceable, to restore hydraulic clearance after wear.

Key Technical Specifications (Cooling Water Duty)

ParameterOH1 (Foot‑mounted)OH2 (Centreline‑mounted)
Flow range10 – 1,000 m³/h (44 – 4,400 GPM)10 – 1,000 m³/h (same)
Head range10 – 100 m (33 – 330 ft)10 – 100 m
Max temperatureUp to 80°C (176°F)Up to 120°C (248°F); higher on request
Pressure ratingUp to 2.0 MPa (20 bar)Up to 2.5 MPa (25 bar)
Speed1,450 / 2,900 rpm (50Hz) or 1,750 / 3,500 rpm (60Hz)
Design pressureANSI Class 150 / 300ANSI Class 150 / 300
NPSHrOptimised (<3‑5 m)Same
Pump efficiency75‑85% at BEPSame
Design life20 years minimum20 years minimum

Materials – Cast Iron or 316L Stainless Steel

Cooling water may be clean, but often contains chlorides, biological growth, or treatment chemicals (corrosion inhibitors, biocides). The selection of materials depends on water quality.

ComponentStandard Material (cast iron)Upgrade Material (316L SS)Remarks
CasingCast iron (GG25) epoxy coated316L stainless steel (CF3M)Cast iron is economical for clean fresh water; 316L for corrosive water (seawater, brackish, high chlorides)
ImpellerCast iron or bronze316L stainless steelBronze for marine applications; stainless for high‑chloride
Shaft4140 or 2Cr13 stainless316 stainless steel–
Wear ringsCast iron / bronze316L SS + Stellite–
Mechanical seal facesCarbon vs. ceramicSilicon carbide vs. carbon or SiC/SiCSilicon carbide for abrasives or higher temperature
GasketsNon‑asbestos / EPDMPTFE / Viton–

Material guidelines

  • For fresh cooling water (river, lake, cooling tower make‑up) with low chloride (<500 ppm): Cast iron casing + bronze impeller is sufficient and cost‑effective.

  • For brackish water or cooling water with chlorides (500‑5,000 ppm): 316L stainless steel wetted parts (casing, impeller, shaft) to prevent pitting and rust.

  • For seawater cooling (Cl⁻ >20,000 ppm): Super duplex (D‑1/D‑2) , not covered by standard OH1/OH2 material package, but available on special order.

All materials supplied with EN 10204 Type 3.1 certification and full traceability.

Mechanical Seals – API 682 Plan 11 (Standard) for Cooling Water

Cooling water at 10‑120°C is generally clean and non‑hazardous, so a simple single mechanical seal with Plan 11 (self‑flush) is standard. Plan 11 uses the pump’s own discharge pressure to circulate a small flow of water from the pump casing through the seal chamber, cooling and lubricating the seal faces.

Seal ArrangementAPI 682 PlanSuitability for Cooling Water
Single cartridge seal with self‑flushPlan 11Standard – simple, reliable, cost‑effective for clean cooling water
Single seal with cooled flushPlan 21For higher temperature (>80°C) to cool flush before entering seal chamber – optional
Single seal with quenchPlan 62Water or steam quench on atmosphere side to prevent salt crystal buildup (for seawater / brackish)
Tandem seal (Arrangement 2)Plan 52For critical applications where leakage cannot be tolerated (not typical for open cooling loops)

Recommended seal face materials – Carbon vs. ceramic is economical and works well for clean water up to 80°C. For higher temperature (80‑120°C) or for water containing fine sand/silt, use silicon carbide vs. carbon or silicon carbide vs. silicon carbide. Elastomers: EPDM (standard for water) or Viton (FKM) for higher temperature.

NPSH Considerations

Cooling water pumps often take suction from a basin, pond, or cooling tower cold water basin with good NPSHa (3‑10 metres). However, care must be taken:

  • If the pump is located above the water source (e.g., on a platform), NPSHa may be limited. The first‑stage impeller should be selected for low NPSHr.

  • If the water is hot (e.g., direct suction from condenser hot well), NPSHa may be low. An inducer or double‑suction impeller may be required.

  • Ensure NPSHa ≥ NPSHr + 1.0 m per API 610.

Cooling Water System Characteristics

  • Continuous duty – Cooling water pumps may run 8,000 hours per year. Bearings and seals must be designed for extended operation.

  • Variable flow – Some systems use two‑pump operation, VFD control, or valve throttling. The pump head‑flow curve should be stable, rising continuously to shut‑off.

  • Parallel operation – Multiple cooling water pumps often operate in parallel. The pump curve should be non‑overloading and have a continuously rising characteristic to avoid hunting.

  • Materials – Cooling water may be treated with chlorine, ozone, UV, or other biocides. Ensure elastomers and gaskets are compatible.

Applications

Industry / SettingSpecific Service
Power plantsCondenser cooling water circulation (once‑through or closed loop); auxiliary cooling water
Petrochemical / refineryCooling water to heat exchangers, coolers, and air fin coolers
Chemical plantsProcess cooling loops; reactor jacket cooling
HVAC (large commercial / industrial)Chilled water circulation; condenser water circulation in chillers (usually vertical inline, but OH1/OH2 used for larger systems)
Steel millsRoll cooling; furnace cooling
Paper & pulp millsProcess water cooling; machine cooling
Data centresCooling water circulation for air handling units

Why Choose an API 610 OH1/OH2 Circulating Cooling Water Pump from This China Manufacturer

  • API 610 full compliance (OH1/OH2) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.

  • Proven reliability – Thousands of units in cooling water service. Overhung, back pull‑out design minimises downtime.

  • Material flexibility – Cast iron (economical) or 316L stainless steel (corrosion resistance).

  • OH1 (foot‑mounted) for ambient to warm water (≤80°C)

  • OH2 (centreline‑mounted) for hot cooling water (≤120°C) – prevents misalignment due to thermal expansion.

  • Back pull‑out design – Seal replacement, bearing inspection, and impeller cleaning without removing piping.

  • API 682 Plan 11 seal – Simple, reliable cooling water sealing.

  • High efficiency – Up to 85% at BEP, reducing annual energy costs.

  • VFD ready – Suitable for variable frequency drive operation where flow demand varies.

  • Certified China manufacturer – API Q1, ISO 9001, with global references.

  • Competitive pricing – Factory direct with short lead times.

Quality Assurance & Testing (Per API 610)

  • Hydrostatic test – Casing tested at 1.5× design pressure

  • Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional)

  • Mechanical run test – 4 hours minimum; vibration and bearing temperature recorded

  • NPSH test – Optional on request

  • Impeller dynamic balancing – Grade G6.3 or better

  • Material certification – EN 10204 3.1 for all wetted parts

  • Third‑party inspection – Available (DNV, Lloyds, BV, SGS)

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 11 ready)1 set
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller)1 set
Impeller1 (for critical duty)
Shaft1 (for critical duty)
Gasket / O‑ring kit (full set)1 set

Get a Quote or Engineering Support

For detailed selection of the correct API 610 OH1 / OH2 circulating cooling water pump for your application – including flow, head, cooling water temperature (ambient to 120°C), water quality (fresh, brackish, seawater), NPSHa, material (cast iron vs. 316L), and configuration (OH1 foot‑mounted or OH2 centreline‑mounted) – please contact our engineering team.

Email: info@hyrig.com

*Our API 610 OH1/OH2 circulating cooling water pumps are specifically engineered for continuous, high‑reliability cooling water circulation – handling flows to 1,000 m³/h, heads to 100 m, and temperatures to 120°C. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with back pull‑out design, Plan 11 mechanical seals, and material options for fresh or corrosive cooling water.*


Comment