The high pressure process water pump is a specialised, heavy‑duty multistage centrifugal pump designed to generate high discharge pressure (heads 300‑600 metres) for a variety of industrial water services. Typical applications include high‑pressure transfer of treated water, reverse osmosis (RO) feed in desalination and water treatment plants, booster service for industrial boiler feed systems, cooling water circulation in high‑rise circuits, and long‑distance raw water pipelines. The pump is classified under API 610 (ISO 13709) as Type BB3 – a horizontal, single‑casing, axially split, centreline‑mounted, between‑bearings, multistage centrifugal pump.
The BB3 pump is ideally suited for high‑head, moderate‑flow, continuous process water duties. The axially split casing allows full rotor access without disturbing suction or discharge piping. Opposed back‑to‑back impellers produce hydraulic axial thrust self‑balance, eliminating complex balance discs or drums. Double volute stages balance radial thrust, and centreline mounting accommodates thermal expansion. The materials are selected for economy and durability: a robust carbon steel casing (C‑6) provides strength and pressure containment, while stainless steel (304 or 316L) internal parts – impellers, diffusers, wear rings, and shaft sleeves – give excellent corrosion resistance to treated water, demineralised water, and mildly aggressive industrial water at 104‑150°C. This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, decades of severe‑duty pumping experience, and thousands of BB3 pumps installed in industrial water, process, and power plants worldwide.
| Feature | Description |
|---|---|
| API 610 Type | BB3 (axial split, single casing, between‑bearings) |
| Casing form | Axially split volute (horizontal split) |
| Casing material | Carbon steel (Class II – API 610 C‑6) |
| Internal wetted parts | Stainless steel (304 / 316L – API 610 S‑8) |
| Casing type | Single casing (non‑barrel) |
| Bearing support | Between‑bearings – two bearing brackets at drive end and non‑drive end |
| Number of stages | 4 to 12 (depending on head requirement: 300‑600 m) |
| Impeller arrangement | Opposed (back‑to‑back) for axial thrust self‑balance |
| Volute design | Double volute to balance radial thrust |
| Suction type | Single‑suction first stage; double‑suction low‑NPSH option |
| Mounting | Centreline‑mounted (feet on casing centreline) |
| Nozzle orientation | Suction and discharge nozzles integrally cast with lower half casing |
| Flange rating | ANSI Class 300 / 600 / 900 |
| Compliance | API 610 11th / 12th edition (ISO 13709) |
Axially split casing – The casing is split horizontally along the centreline; the upper half can be removed without disconnecting suction or discharge piping. This provides full access to the rotor, impellers, wear rings, and seal chamber – essential for maintenance. All internal maintenance and replacement can be performed without removing inlet and outlet pipes.
Between‑bearings rotor – Extremely high shaft stiffness minimises deflection even at 600 metres head, extending mechanical seal and bearing life.
Opposed back‑to‑back impellers – Successive stages are arranged in opposing directions. Each pair generates equal and opposite axial thrust. The rotor is hydraulically self‑balanced without complex balance discs, drums, or heavy thrust bearings – eliminating components that wear or foul.
Double volute diffuser design – Each stage contains double volute passages; radial hydraulic forces are self‑balanced over the entire operating range, reducing shaft deflection and increasing reliability.
Centreline mounting – Feet are located on the casing centreline; the pump expands uniformly when handling process water at 104‑150°C, preventing shaft misalignment and bearing distress.
Material combination (carbon steel casing + stainless steel internals) – This hybrid construction offers an optimal balance of cost and corrosion resistance. The carbon steel casing (C‑6) withstands high pressure (up to 100 bar) and provides strength; the stainless steel (304/316L) internals resist rust, pitting, and erosion at elevated temperatures and in demineralised water. No rust particles contaminate downstream equipment.
Hydraulic performance – Heads of 300‑600 metres are easily achieved with 4‑12 stages, each contributing 50‑75 metres per stage. The pump has a steep, stable head‑flow curve rising continuously to shut‑off, suitable for parallel operation.
| Parameter | Range |
|---|---|
| Flow | 50 – 1,500 m³/h (220 – 6,600 GPM) – typical 200‑800 m³/h |
| Head | 300 – 600 m (980 – 1,970 ft) |
| Discharge pressure | Up to 100 bar (1,450 psi) – depending on head and water density |
| Temperature | 104 – 150°C (219 – 302°F) |
| Number of stages | 4 – 12 (customised for exact head) |
| Speed | 1,450 / 2,950 rpm (50Hz) or 1,750 / 3,550 rpm (60Hz) |
| Flange connection | ANSI Class 300 / 600 / 900 raised face |
| Casing material | Carbon steel (API 610 C‑6, Class II) |
| Impeller / diffuser material | Stainless steel 304 / 316L (API 610 S‑8) |
| Shaft material | 4140 hardened steel (coated) or 316 SS |
| Wear rings | Stainless steel + Stellite hard‑facing |
| NPSHr | Optimised (≤5‑7 m depending on first‑stage design); double‑suction option reduces by 30‑40% |
| Pump efficiency | 75‑85% at BEP |
| Design life | 20 years minimum |
This hybrid material selection is specifically chosen for high pressure process water at 104‑150°C. It balances cost (carbon steel casing) with corrosion resistance (stainless steel wetted internals).
| Component | Material | API 610 Class | Remarks |
|---|---|---|---|
| Casing (volute) | Carbon steel (cast or forged) | C‑6 | Economical, high strength, suitable for process water pressure containment |
| Casing cover | Carbon steel | C‑6 | – |
| Impellers (all stages) | Stainless steel 304 / 316L | S‑8 | Corrosion resistance, no rust contamination |
| Diffusers / interstage channels | Stainless steel 304 / 316L | S‑8 | – |
| Shaft | 4140 hardened steel (standard) ; 316 SS optional | C‑6 / A‑8 | 4140 offers high strength; 316 SS for aggressive water |
| Wear rings (casing side) | Stainless steel + Stellite hard‑facing | – | Abrasion resistance |
| Wear rings (impeller side) | Stainless steel + Stellite hard‑facing | – | – |
| Shaft sleeve (at seal) | Stainless steel 316 | – | Protects shaft from corrosion/wear |
| Fasteners (casing bolts) | 4140 (B7) standard; 316 SS optional | – | – |
| Gaskets / O‑rings | Spiral wound graphite (casing joints) ; PTFE / Viton (seals) | – | High temperature compatible |
Carbon steel casing – For high head (up to 600 m), the casing must withstand high internal pressure. Carbon steel provides the required strength at lower cost than stainless steel. The water is treated process water, not highly corrosive, so carbon steel is acceptable for the pressure‑containing envelope.
Stainless steel internals – Impellers, diffusers, wear rings, and shaft sleeves are entirely in contact with the water and should not rust or corrode. Stainless steel (304 or 316L) provides excellent resistance to oxygenated hot water (104‑150°C), prevents iron oxide contamination downstream (critical for RO membranes, boilers, or sensitive equipment), and offers good erosion resistance. 316L is preferred for higher chloride levels or when water chemistry is aggressive.
All materials supplied with EN 10204 Type 3.1 certification and full traceability.
Process water at 104‑150°C requires a seal plan that prevents flashing and maintains cooling. Plan 23 (recirculation with external cooler) is the standard for high‑temperature water services.
| Seal Arrangement | API 682 Plan | Suitability |
|---|---|---|
| Single seal with recirculation cooler | Plan 23 | Recommended – fluid recirculates from seal chamber through an external cooler and back, maintaining seal face temperature below vapourisation point |
| Single seal with cooled flush from discharge | Plan 21 | Acceptable alternative – takes hot water from pump discharge, passes through a cooler, then injects into seal chamber |
| Single seal with self‑flush | Plan 11 | Not suitable – hot water would flash across seal faces |
| Tandem seal | Plan 52 | Higher reliability for critical services |
| Dual pressurised (Arrangement 3) | Plan 53B | For hazardous fluid – not required for clean process water |
Plan 23 operational principle – A closed loop continuously circulates fluid from the seal chamber through an external cooler (air‑cooled or water‑cooled), returning cooled fluid to the seal. The seal chamber is thus always filled with cool, liquid‑phase water, preventing flashing and keeping seal faces cool. The external cooler is properly piped to ensure continuous circulation by thermal siphon.
Recommended seal faces – Silicon carbide vs. carbon (standard for water). Silicon carbide vs. silicon carbide may be specified for higher reliability or abrasive water. Elastomers: Viton (FKM) – handles up to 200°C.
Seal flush piping – Must be rated for 150°C and 1.5 times pump discharge pressure. The external cooler should be sized to reduce fluid temperature to ≤70°C before returning to the seal chamber.
High head pumps (300‑600 m) require careful attention to NPSHa. The pump typically takes suction from a tank, deaerator, or pipeline with limited liquid level or pressure.
Single‑suction first‑stage (standard) – sufficient if NPSHa ≥ 5‑7 m.
Double‑suction first‑stage impeller – reduces NPSHr by 30‑40%; strongly recommended when NPSHa ≤ 5 m.
Inducer – optional axial flow inducer reduces NPSHr by 40‑60% for very low NPSHa (e.g., < 3 m).
Ensure NPSHa ≥ NPSHr + 1.0 m per API 610. For hot water near boiling point, add an extra 1‑2 m margin because water is near vapour pressure.
During start‑up, shutdown, or low load, the pump must be protected against operation below Minimum Continuous Stable Flow (MCSF). An automatic recirculation valve (ARC) or a continuous bypass line with orifice returns the required minimum flow (typically 20‑30% of BEP flow) to the suction source. The ARC senses flow and opens the bypass when flow drops, preventing overheating, cavitation, and seal damage. This is critical for multistage pumps with high energy input per stage.
| Industry / Setting | Specific Service |
|---|---|
| Industrial water treatment | Reverse osmosis (RO) high‑pressure feed for seawater or brackish water desalination |
| Power plants | Boiler feed booster pump (pre‑charging before main BFP); high‑pressure cooling water |
| Petrochemical / refinery | Process water injection; high‑pressure wash water; cooling water circulation in tall columns |
| Steel & metal industries | Descaling water supply; high‑pressure cooling circuits |
| Municipal water | Long‑distance raw water transfer; high‑rise building pressure boosting |
| Paper & pulp industry | High‑pressure water for showers and cleaning systems |
| Mining | High‑pressure process water for ore processing |
Full API 610 compliance (BB3) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.
Axially split casing – Maintenance without removing piping; full rotor access in hours.
Between‑bearings high‑rigidity rotor – Low vibration, extended bearing and seal life even at 600 m head.
Opposed back‑to‑back impellers – Hydraulic axial thrust self‑balance eliminates balance discs and drums – simplified construction, no wear components.
Double volute casing – Radial thrust self‑balance over entire operating range; reduces shaft deflection and bearing load.
Centreline mounting – Accommodates thermal expansion at 104‑150°C; prevents misalignment.
Hybrid materials: carbon steel casing + stainless steel internals – Cost‑effective pressure containment with corrosion‑resistant wetted parts; no iron contamination downstream.
API 682 Plan 23 – External cooler recirculates cooled water around seal faces; prevents flashing in high‑temperature service.
Low NPSH options – Double‑suction first‑stage impeller and inducer available for low NPSHa.
Broad hydraulic coverage – Flow 50‑1,500 m³/h, head 300‑600 m, pressure to 100 bar.
Certified China manufacturer – API Q1, ISO 9001, with global references in industrial water and process plant projects.
Proven in process water service – Thousands of BB3 pumps operating worldwide in demanding high‑head water applications.
Hydrostatic test – Casing tested at 1.5× MAWP.
Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).
Mechanical run test – 4 hours minimum continuous operation at rated speed; vibration and bearing temperature recorded.
NPSH test – Optional, when specified.
Impeller dynamic balancing – Grade G6.3 or better.
Material certification – EN 10204 3.1 for all pressure‑containing components and stainless steel internals.
PMI (Positive Material Identification) – Available on request for alloy verification.
NDE – Dye penetrant on castings; ultrasonic on shafts; as required by API 610.
Third‑party inspection – Available (DNV, Lloyds, BV, SGS).
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 23 ready) | 1 set |
| Bearing set (radial cylindrical + angular contact) | 1 set |
| Wear ring set (casing + impeller) – stainless steel | 1 set |
| Interstage bushings | 1 set |
| Impeller set (all stages) – stainless steel | 1 set (for critical duty) |
| Shaft (4140 or 316 SS) | 1 (for critical duty) |
| Gasket / O‑ring kit (full set) | 1 set |
| Inducer (if fitted) | 1 set |
For detailed selection of the correct API 610 BB3 high pressure process water pump for your industrial water, RO feed, or high‑head transfer project – including flow, head (300‑600 m), operating temperature (104‑150°C), water chemistry, NPSHa, material selection (carbon steel casing + stainless steel internals), and API 682 seal plan – please contact our engineering team.
Email: info@hyrig.com
*Our API 610 BB3 high pressure process water pumps are specifically engineered for high‑head, high‑temperature, and high‑reliability water service – handling up to 600 m head and 150°C with proven performance. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with axially split casing, opposed impeller axial balance, double volute radial balance, and Plan 23 seal cooling. Carbon steel casing + stainless steel internals provide optimal cost‑performance for process water applications.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.