Eddy Current Brakes
Design Features
1. DS water-cooled eddy current brakes are suitable for auxiliary brake requirement of drawworks for rigs with depth range of 4000~9000m (4 1/2" drill pipe).
2. The rotor and the stator are made of high quality magnetic materials and subjected to heat treatment. There is a gap between rotor and magnetic pole so no wear occurs during operation.
3. Coils are made of single polyimide wire wrapped with glass fibre and are dip coating of vacuum pressure in twice. The insulation level is Class F or H.
4. The cooling water is supplied by a circulating water pump to ensure that the heat generated by the brake can be dissipated even under maximum load.
5. Rotor shafts are supported on double-row radial spherical roller bearings.
6. To connect with the drum shaft by means of involute spline tooth clutch
Specifications of Eddy Current Brakes
| Model | DS40 |
| Rated stop torque kN.m(Lb.-Ft.) | 44(32600) |
| Applicable depth range m | 2500-4000 |
| Max.Exciting power KW | 9 |
| Exciting coil(H Class) | 4 |
| Amount of cooling water L/min(gpm) | 190(50) |
| Max.Temperature of inlet water ℃ | 42 |
| Max.Temperature of outlet water ℃ | 72 |
| Model | DS50 |
| Rated stop torque kN.m(Lb.-Ft.) | 60.76(45000) |
| Applicable depth range m | 3500-5000 |
| Max.Exciting power KW | 12 |
| Exciting coil(H Class) | 4 |
| Amount of cooling water L/min(gpm) | 285(75) |
| Max.Temperature of inlet water ℃ | 42 |
| Max.Temperature of outlet water ℃ | 72 |
| Model | DS70 |
| Rated stop torque kN.m(Lb.-Ft.) | 107.8(79500) |
| Applicable depth range m | 4500-7000 |
| Max.Exciting power KW | 23.5 |
| Exciting coil(H Class) | 4 |
Amount of cooling water L/min(gpm) | 560(148) |
| Max.Temperature of inlet water ℃ | 42 |
| Max.Temperature of outlet water ℃ | 72 |
| Model | DS80 |
| Rated stop torque kN.m(Lb.-Ft.) | 130(95940) |
| Applicable depth range m | 5000-8000 |
| Max.Exciting power KW | 25 |
| Exciting coil(H Class) | 4 |
| Amount of cooling water L/min(gpm) | 700(184) |
| Max.Temperature of inlet water ℃ | 42 |
| Max.Temperature of outlet water ℃ | 78 |
| Model | DS90 |
| Rated stop torque kN.m(Lb.-Ft.) | 145(107010) |
| Applicable depth range m | 6000-9000 |
| Max.Exciting power KW | 30 |
| Exciting coil(H Class) | 4 |
| Amount of cooling water L/min(gpm) | 800(211) |
| Max.Temperature of inlet water ℃ | 42 |
| Max.Temperature of outlet water ℃ | 78 |
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.