Evaporation Circulation Pump – API 610 BB2 Radially Split Between‑Bearings Centrifugal Pump for NH₄Cl Crystallization by Leading China 610 Pump Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 BB2 radially split, between‑bearings, single‑stage centrifugal pump specifically engineered for forced circulation evaporation in ammonium chloride (NH₄Cl) crystallization and separation circuits – Hou`s process / Union process soda ash plants. Handles high‑chloride brine (Cl⁻ 60,000‑100,000 ppm) with 5‑15% entrained NH₄Cl crystals at moderate temperatures (‑5 to 25°C). Duplex 2205 or super duplex 2507 wetted parts resist chloride pitting, SCC, and crystal abrasion. Heavy‑duty between‑bearings construction minimises shaft deflection and ensures long service life under continuous, low‑head, high‑flow forced circulation duty. API 682 mechanical seals with Plan 32 external flush or Plan 53B. Manufactured by a certified China API 610 pump manufacturer with full API Q1 certification. Flow 400‑2,500 m³/h, head 20‑100 m. 20‑year design life, 3‑year continuous operation.


Conatct For Details
DetailReview(0)Additional

Product Overview

The evaporation circulation pump is a specialised, heavy‑duty centrifugal pump designed to provide forced circulation in ammonium chloride (NH₄Cl) evaporation crystallizers in Hou`s process (combined process / Union process) soda ash plants. After the cold crystallization and salting out stages, the mother liquor – a concentrated brine containing NH₄Cl, NaCl, free ammonia, and fine NH₄Cl crystals – is fed to evaporative crystallizers where water is removed to produce high‑purity NH₄Cl crystals. The forced circulation pump recirculates the slurry through an external heat exchanger at high velocity, maintaining supersaturation control and preventing crystal settling or fouling on heat transfer surfaces.

This forced circulation service is extremely demanding due to:

  • High flow, low head – Typical duty requires large volumes of slurry to be circulated with relatively low pressure rise (2‑10 metres per pass).

  • High chloride concentration (Cl⁻ 60,000‑100,000 ppm) – extremely corrosive, requiring high‑performance alloys to prevent pitting and stress corrosion cracking (SCC).

  • Entrained NH₄Cl crystals (5‑15%) – abrasive, causing wear on impellers, wear rings, and seal faces.

  • Corrosive ammonia – free ammonia in the brine attacks copper alloys and some elastomers.

  • Continuous duty – evaporation circulation pumps run 24/7 for months or years without interruption.

This pump is classified under API 610 (ISO 13709) as Type BB2 – a radially split, between‑bearings, single‑stage or two‑stage centrifugal pump. The BB2 design is ideal for forced circulation evaporator service because the between‑bearings support provides high rotor rigidity and low vibration even under high‑flow, low‑head conditions, while the radially split casing offers excellent pressure containment and easy maintenance.

This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, extensive experience in corrosion‑resistant alloys for high‑chloride service, and thousands of BB2 pumps operating in NH₄Cl crystallization and other demanding chemical processes worldwide.

Construction & API 610 Classification

FeatureDescription
API 610 TypeBB2 (radially split, between‑bearings, single‑stage)
Casing formRadially split, double volute
Bearing supportBetween‑bearings – bearings at both drive end and non‑drive end
Number of stagesSingle‑stage (typical for forced circulation); two‑stage options available for higher head
Suction typeSingle‑suction or double‑suction (to reduce NPSHr)
Nozzle orientationSide‑suction / side‑discharge (standard) or top‑suction / top‑discharge
Flange ratingANSI Class 150 / 300 (typically lower pressure for evaporator circulation)
Pressure ratingUp to 5‑10 MPa depending on configuration – evaporator circulation typically lower
ComplianceAPI 610 11th / 12th edition (ISO 13709)

Why BB2 for NH₄Cl Evaporation Circulation

  • Between‑bearings rotor – Extremely high shaft stiffness minimises deflection even at high flow rates, extending seal and bearing life. This is critical for continuous, 24/7 forced circulation duty.

  • Radially split casing – Provides superior pressure containment. The double volute design balances radial forces, reducing vibration and bearing load.

  • Double‑suction first stage (available) – Reduces NPSH required – essential when the evaporator body is at vacuum or low pressure and NPSHa is limited.

  • Large internal passages – Handles entrained NH₄Cl crystals without clogging.

  • Heavy‑duty bearings – Designed for continuous operation with L10 life ≥25,000 hours.

  • Centreline mounting – Accommodates thermal expansion; suitable for moderate temperature ranges (‑5 to 25°C standard, up to 150°C for heated circulation).

Key Technical Specifications (Evaporation Circulation Duty)

ParameterDesign Range
Flow rate400 – 2,500 m³/h (1,760 – 11,000 GPM)
Head20 – 100 m (65 – 330 ft) – typical forced circulation head 20‑60 m
Fluid temperature-5 to 25°C (23 to 77°F) – crystallizer temperature; up to 150°C with special design
Fluid compositionNH₄Cl brine (25‑28%), NaCl, free ammonia, fine NH₄Cl crystals
Chloride concentration60,000 – 100,000 ppm (6‑10% Cl⁻)
Solids content5‑15% fine NH₄Cl crystals (entrained)
Specific gravity1.10 – 1.20
pH7 – 9 (ammoniacal)
Maximum pressure0.5 – 1.5 MPa (5 – 15 bar – typical evaporator circulation)
Speed980 / 1,450 / 1,480 rpm (slow speed for large vol**umes and abrasion resistance)
NPSHrOptimised (<3‑5 m) – double‑suction option significantly lowers NPSHr
Pump efficiency75‑85% (depending on size and hydraulic design)
Design life20 years minimum

Materials – Duplex 2205 / Super Duplex 2507 for High Chloride & Crystal Abrasion

Standard 316L stainless steel (S‑8) is not sufficient for prolonged exposure to Cl⁻ > 50,000 ppm in NH₄Cl brine, especially with abrasive crystals. Higher alloys are required to resist both chloride pitting and mechanical wear from crystals.

ComponentRecommended MaterialAPI 610 ClassPREN
CasingDuplex 2205 or Super Duplex 2507D‑1 / D‑235‑42
ImpellerDuplex 2205 (hardened) or Super Duplex 2507D‑1 / D‑235‑42
ShaftDuplex 2205 or super duplexD‑1 / D‑2–
Wear ringsDuplex 2205 + Stellite hard‑facing or tungsten carbide coating––
Seal chamberDuplex 2205D‑1–
FastenersDuplex or super duplex––
GasketsPTFE or Viton (FKM)––

Material Guidelines for NH₄Cl Evaporation Circulation

  • For Cl⁻ 60,000‑80,000 ppm → Duplex 2205 (D‑1) is the standard and cost‑effective choice. PREN 35‑38 provides excellent pitting resistance and high strength.

  • For Cl⁻ >80,000 ppm or risk of SCC / crevice corrosion → Super Duplex 2507 (D‑2 / U‑8) is recommended for its higher PREN (>40) and superior chloride resistance.

  • Crystal abrasion protection – Alloy hardness and surface finish are critical. Duplex alloys offer high mechanical strength; for extreme abrasion (high‑velocity crystal slurry), Stellite hard‑facing on wear rings and tungsten carbide on seal faces are recommended.

  • All materials supplied with EN 10204 Type 3.1 certification and full traceability. Positive Material Identification (PMI) available on request.

  • NACE MR0175 is not typically required for NH₄Cl service (no H₂S), but can be provided if specified.

Mechanical Seals – API 682 for Abrasive Crystalline Slurry

The forced circulation pump handles 5‑15% NH₄Cl crystals at high velocities. Abrasion is the primary threat to seal life, followed by corrosion. External clean flush is essential to wash crystals away from seal faces.

Seal ArrangementAPI 682 PlanSuitability for NH₄Cl Evaporation Pump
Single seal with external clean flushPlan 32Highly recommended – continuous injection of clean external fluid (clarified NH₄Cl solution or warm water) at 1‑2 bar above pump suction pressure flushes crystals away from seal faces. This is the most effective way to prevent seal face abrasion.
Dual pressurised (Arrangement 3)Plan 53BZero emissions, but barrier fluid alone does not flush solids – ideally combined with Plan 32 for crystal flushing
Tandem seal (Arrangement 2)Plan 52Acceptable for lower head services (<5 bar) when combined with Plan 32
Single seal with quenchPlan 62Not sufficient for high solids / crystalline slurries

Recommended Seal Face Materials

  • Tungsten carbide vs. tungsten carbide – Extremely hard (>1,800 Hv), best abrasion resistance for NH₄Cl crystals. This is the preferred choice for evaporation circulation pumps with high crystal loading.

  • Silicon carbide vs. tungsten carbide – Tungsten carbide on one side for abrasion resistance.

  • Silicon carbide vs. silicon carbide – Hard but less abrasion‑resistant than tungsten carbide; acceptable for lower crystal loading (<5‑10%).

Elastomers: Viton (FKM) – compatible with NH₄Cl brine and ammonia at -5 to 25°C; Aflas or Kalrez for superior chemical resistance and broader temperature range.

Critical Design Feature – Plan 32 External Flush

Plan 32 is strongly recommended for this service. An external clean flush fluid (clarified NH₄Cl solution or warm water) is injected into the seal chamber at 1‑2 bar above pump suction pressure, continuously flowing across the seal faces and preventing crystals from entering. The flush flow rate should be 5‑15 L/min depending on pump size and crystal loading.

NPSH and Suction Considerations for Evaporator Pumps

Evaporation circulation pumps often take suction from an evaporator body operating below atmospheric pressure (vacuum) or at very low liquid head. NPSHa can be critically low.

  • Double‑suction impeller option – The suction impeller can be arranged as a double inlet. This significantly reduces the fluid velocity at the pump inlet, lowering NPSHr by 30‑40%.

  • Low NPSHr impeller design – Optimised inlet geometry for forced circulation service.

  • Inducer option – Axial inducer reduces NPSHr by 40‑60%; highly beneficial when NPSHa < 3 m.

  • Maintain NPSHa ≥ NPSHr + 1.0 m per API 610 and best practice.

Forced Circulation Evaporator Design Features

  • High flow, low head – The pump is designed for high volumetric flow with relatively low differential head (2‑10 metres per pass through the heat exchanger). The BB2’s single‑stage configuration is ideal for this.

  • Abrasion‑resistant impeller – Closed impeller with hard surface finish or open impeller with replaceable wear plate.

  • Slurry handling – Wide internal passages, no tight clearances that would trap crystals.

  • Heavy‑duty shaft – Large diameter with minimal deflection to maintain wear ring clearances and protect the seal.

  • Vertical or horizontal orientation – Horizontal BB2 is standard; vertical configuration available for low‑NPSHa installations.

Applications

IndustrySpecific ServiceTypical Head
Soda ash (Hou`s / Union process) | Forced circulation in NH₄Cl evaporative crystallizers | 2‑10 m per pass |

Ammonium chloride productionRecirculation of mother liquor through external heating calandria20‑60 m
Potash / fertilizer productionKCl crystallizer circulationSimilar chloride brine service
Salt production (NaCl)Evaporative crystallizer circulation20‑60 m
Zero Liquid Discharge (ZLD) systemsBrine concentrator circulation20‑60 m

Why Choose an API 610 BB2 Evaporation Circulation Pump from This China Manufacturer

  • API 610 full compliance (BB2) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.

  • Radially split between‑bearings design – High rotor rigidity, low vibration, minimal shaft deflection under high flow conditions.

  • Duplex / super duplex wetted parts – Superior resistance to chloride pitting, SCC, and erosion (PREN 35‑42).

  • Designed for forced circulation service – Double‑suction option, wide passages, abrasion‑resistant impeller, low NPSHr.

  • API 682 Plan 32 external flush – Essential for preventing seal face abrasion from NH₄Cl crystals.

  • API 682 Plan 53B option – Zero emissions for barrier fluid when required.

  • Low NPSH capability – Double‑suction impeller and inducer options for vacuum evaporator service.

  • Broad hydraulic coverage – Flows 400‑2,500 m³/h, heads 20‑100 m, covering all NH₄Cl evaporator circulation duties.

  • Certified China manufacturer – API Q1, ISO 9001, with global references in soda ash and chemical industries.

  • Proven in NH₄Cl crystallization – Thousands of BB2 pumps operating in ammonium chloride evaporation and forced circulation circuits worldwide.

Quality Assurance & Testing (Per API 610)

  • Hydrostatic test – Casing tested at 1.5× MAWP.

  • Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).

  • Mechanical run test – 4 hours minimum; vibration and bearing temperature recorded.

  • NPSH test – Optional, when specified (recommended for vacuum evaporator service).

  • Impeller dynamic balancing – Grade G6.3 or better.

  • Material certification – EN 10204 3.1 for all pressure‑containing components; PMI available.

  • NDE – Dye penetrant on castings; ultrasonic on shafts as required.

  • Third‑party inspection – Available (DNV, Lloyds, BV, SGS).

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (Plan 32 ready, tungsten carbide faces)1 set
Wear ring set (casing + impeller)1 set
Bearing set (radial + thrust)1 set
Impeller1 set
Shaft1 (for critical duty)
Gasket / O‑ring kit (full set)1 set

Get a Quote or Engineering Support

For a detailed selection of the API 610 BB2 evaporation circulation pump for your NH₄Cl crystallizer or forced circulation evaporator – including flow, head (pressure rise per pass), chloride concentration, crystal loading, evaporator operating conditions (vacuum / atmospheric), NPSHa, material (Duplex 2205 vs. Super Duplex 2507), and API 682 seal plan (Plan 32 with tungsten carbide) – please contact our engineering team.

Email: info@hyrig.com

*Our API 610 BB2 evaporation circulation pumps are specifically engineered for the most demanding ammonium chloride forced circulation service – handling high‑chloride brine with 5‑15% entrained NH₄Cl crystals. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with duplex / super duplex wetted parts, outside, double‑suction low‑NPSH capability, and Plan 32 external flush for crystal abrasion protection.*


Comment

comment
Name
Praise degree
Message:
Upload pictures: