The large ammonia brine circulation pump is the core rotating equipment in soda ash production plants (Solvay / Hou`s process). It delivers prepared ammonia brine (NH₃ + NaCl + H₂O) from the ammonia brine storage or mixer to the carbonating towers and maintains forced circulation of the entire ammonia brine system. The pump is classified under API 610 (ISO 13709) as Type BB1 – an axially split, between‑bearings, single‑stage, single‑suction volute centrifugal pump.
The BB1 configuration is ideal for high‑flow, moderate‑head, continuous heavy‑duty service. The between‑bearings design provides excellent rotor stiffness, while the axially split casing allows the top half to be removed without disturbing suction and discharge piping – enabling easy rotor access for maintenance. The single‑stage design eliminates multi‑stage axial thrust balance issues and handles suspended crystal particles that may be present in ammonia brine.
This pump series is fully compliant with API 610 11th/12th edition (ISO 13709) , offering a 20‑year design life and minimum 3‑year uninterrupted operation. It is specifically tailored for large‑scale soda ash plants and combined process (Hou`s process) ammonia brine systems.
| Feature | Description |
|---|---|
| API 610 Type | BB1 (axial split, between‑bearings, single‑stage) |
| Casing type | Horizontally split, double‑volute (optional on large sizes) |
| Bearing support | Two bearing brackets (drive end and non‑drive end) with radial and thrust bearings |
| Number of stages | Single stage |
| Suction type | Single‑suction (double‑suction first‑stage optional for low NPSH) |
| Nozzle orientation | Top suction, top discharge (or side‑suction / side‑discharge as required) |
Axially split casing – Remove the top half without disconnecting piping; full access to rotor, seals, and internal flow passages. Ideal for pumps requiring periodic inspection due to crystallisation or scaling.
Between‑bearings rotor – High shaft stiffness, low vibration, and extended bearing life under high flow rates.
Single‑stage design – No interstage seals; unaffected by small suspended salt crystals that may be present in ammonia brine.
Double‑volute option – Balances radial thrust at off‑BEP conditions; reduces shaft deflection and improves reliability.
Double‑suction first‑stage (optional) – Lowers NPSHr by 30‑40% for low‑NPSHa installations.
| Parameter | Design Range |
|---|---|
| Rated flow | 500 – 5,000 m³/h (typical 2,000‑4,000 m³/h) |
| Rated head | 25 – 80 m |
| Maximum pressure | 2.5 MPa (25 bar) |
| Fluid temperature | 40 – 65°C |
| Fluid density | 1.15 – 1.22 g/cm³ (ammonia brine) |
| NPSHa | Typically 4‑10 m; pump NPSHr ≤ 5 m (≤3 m with double‑suction impeller / inducer) |
| Speed | 980 / 1,450 / 1,480 rpm (low speed for large pumps) |
| Pump efficiency | 80‑88% (depending on size and flow) |
| Motor power | 150 – 1,500 kW |
Ammonia brine contains high chloride concentration (NaCl) and free NH₃. Carbon steel and 304 stainless steel are not suitable for long‑term service. 316L stainless steel or duplex stainless steel is required.
| Component | Standard Material | Upgrade Material | API 610 Class |
|---|---|---|---|
| Casing / cover | 316L stainless steel (CF3M) | Duplex 2205 | S‑8 / D‑1 |
| Impeller | 316L stainless steel | Duplex 2205 / 2507 | S‑8 / D‑2 |
| Shaft | 17‑4 PH or 316 SS | Duplex stainless steel | A‑8 / D‑1 |
| Seal chamber | 316L stainless steel | Duplex | S‑8 |
| Wear rings | 316L SS + Stellite | Duplex + tungsten carbide | – |
| Fasteners | 316 SS | Duplex | – |
316L (S‑8) – Contains 2‑3% molybdenum, resists chloride pitting. Suitable for ammonia brine with Cl⁻ ≤ 20,000 ppm.
Duplex 2205 (D‑1) – PREN >35, superior pitting and crevice corrosion resistance. Recommended for higher chloride levels or fluctuating pH.
Super Duplex 2507 (D‑2 / U‑8) – For extreme conditions (very high Cl⁻ + temperature + oxygen), rarely needed for ammonia brine.
All materials supplied with EN 10204 Type 3.1 traceability.
Free ammonia (NH₃) is toxic and has a pungent odour. Leakage to atmosphere must be prevented. Ammonia brine may also contain small NaCl crystals that can abrade seal faces.
| Seal Arrangement | API 682 Plan | Suitability |
|---|---|---|
| Dual pressurised (Arrangement 3) | Plan 53B (bladder accumulator) | Recommended – Zero emissions; barrier fluid pressure > process; prevents NH₃ escape; barrier fluid flow flushes away crystals |
| Tandem seal (Arrangement 2) | Plan 52 | Acceptable for low NH₃ concentration, but not preferred for main circulation |
| Single seal (Arrangement 1) | Plan 32 (external flush) | Not recommended for high NH₃ service |
Plan 53B is the standard for ammonia brine circulation pumps:
Barrier fluid (glycol/water or oil) pressurised by nitrogen‑charged bladder accumulator, 2‑3 bar above pump casing pressure.
Even if the process‑side seal leaks, barrier fluid enters the pump – not ammonia brine to atmosphere.
Circulation of barrier fluid removes heat and washes away salt deposits from seal faces.
Seal faces: Silicon carbide vs. silicon carbide (hard‑on‑hard) – wear‑resistant and tolerant of fine particles. Elastomers: Viton (FKM) or Kalrez – ammonia‑resistant.
Ammonia brine pumps often take suction from a low‑level storage tank. The liquid is near‑saturated with ammonia and at 40‑65°C, so vapour pressure can be significant.
Double‑suction first‑stage impeller – Reduces NPSHr by 30‑40%; highly recommended for low NPSHa applications.
Inducer – Available to further reduce NPSHr to 1‑2 metres.
Ensure NPSHa ≥ NPSHr + 1.0 m per API 610.
Avoid prolonged operation at low flow (below MCSF) to prevent recirculation cavitation.
| Industry | Specific Service |
|---|---|
| Soda ash production (Solvay / Hou`s process) | Ammonia brine preparation → storage → main circulation to carbonating towers | | |
| Combined process (Hou`s process) | Ammonia brine to carbonating towers; mother liquor recovery | | |
| Large‑scale ammonia plants | Ammonia absorption / recirculation |
| Chlor‑alkali plants | High‑concentration brine circulation |
| Other chemical evaporation / crystallization | Forced circulation of high‑chloride, ammonia‑containing media |
| Feature | BB1 (this pump) | OH2 (overhung) | BB3 (multistage) |
|---|---|---|---|
| Flow range | 500‑5,000 m³/h | ≤1,000 m³/h | 50‑1,500 m³/h |
| Head range | 25‑80 m | 20‑150 m | 100‑1,500 m |
| Rotor stiffness | Very high (between‑bearings) | Moderate (overhung) | High |
| Tolerance of suspended crystals | Good (open volutes, wide passages) | Good | Poor (tight interstage clearances) |
| Maintenance without piping removal | Yes (axial split) | Yes (back pull‑out) | Partial (axial split on some types) |
| Suitability for large‑flow low‑head | Ideal | Limited | Not suitable |
For large‑flow, moderate‑head ammonia brine main circulation, BB1 is the optimal configuration.
Design life: 20 years minimum
Continuous operation: ≥3 years uninterrupted
Bearing L10 life: ≥25,000 hours
Critical speed: ≥120% of maximum operating speed
Centreline mounting (optional for high temperature) – standard foot mounting for 40‑65°C service
Hydrostatic test: 1.5 × design pressure
Performance test: Water per API 610 Grade 2 (Grade 1 optional)
Material certification: EN 10204 3.1 full traceability
Ultra‑high flow capability – Single pump can circulate ammonia brine for tens‑of‑thousands‑tons/year soda ash plants.
Axial split for easy maintenance – Remove top casing without disconnecting piping; reduce downtime by >50%.
High rotor rigidity – Between‑bearings design ensures low vibration and long bearing life.
Corrosion‑resistant materials – 316L/duplex wetted parts resist chloride pitting and ammonia attack.
Zero‑leakage sealing – API 682 Plan 53B dual pressurised seals; eliminates NH₃ emissions.
Low NPSH options – Double‑suction impeller or inducer for low‑headroom installations.
Non‑overloading power curve – Impeller designed to prevent motor overload at high flow.
Flexible drive options – Direct motor or belt drive; horizontal foot‑mounted baseplate.
Hydrostatic test – Casing and covers at 1.5× MAWP.
Performance test – Flow, head, power, efficiency per API 610 Grade 2.
Mechanical run test – 4 hours minimum; vibration and temperature monitoring.
NPSH test – Optional, when specified.
Non‑Destructive Examination (NDE) – PT/MT on castings; UT on shaft forgings.
Material certification – EN 10204 3.1; PMI available on request.
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (Plan 53B ready) | 1 set |
| Bearing set (radial + thrust) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Gasket / O‑ring kit (full) | 1 set |
| Inducer (if fitted) | 1 set |
| Impeller (critical spare) | 1 set |
For a detailed selection of the large ammonia brine circulation pump (API 610 BB1) for your soda ash project – including flow, head, ammonia brine composition (density, chloride level, NH₃ content), NPSHa, and materials – please contact our engineering team.
Email: info@hyrig.com
Our engineering team has supplied over 150 API 610 BB1 ammonia brine circulation pumps for soda ash plants worldwide, with the longest trouble‑free operation exceeding 6 years. Choose BB1 for long cycle life, high efficiency, and zero‑leakage ammonia brine handling.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.