The raw water / seawater deep well pump is a vertical turbine, wet pit, single-casing centrifugal pump specifically engineered for pumping from deep wells, boreholes, sumps, reservoirs, and seawater intake structures. Applications include municipal raw water supply, seawater intake for desalination plants, industrial water supply, cooling water circulation for power plants, irrigation, flood control, and offshore seawater lift. The pump is classified under API 610 (ISO 13709) as Type VS2 – a vertical suspended, wet pit, single-casing diffuser or volute-type pump. The discharge is through the column, with the driver mounted at grade level for easy access and maintenance.
The VS2 pump features a vertically suspended bowl assembly with a surface-mounted driver, flexible shafting, and intermediate sleeve bearings that support the shaft within the pump column. The suction inlet is submerged beneath the bowl assembly, delivering excellent NPSH characteristics critical for volatile or hot liquids. This design makes it ideal for deep well settings, low NPSH conditions, and spaces where horizontal pumps cannot be installed due to footprint limitations. The vertical configuration and positive submerged suction eliminate priming issues and ensure reliable start-up even when the source is below the pump base.
This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, decades of experience in severe-duty pumping, and thousands of VS2 pumps installed in raw water, deep well, and seawater intake services worldwide.
| Feature | Description |
|---|---|
| API 610 Type | VS2 (vertical suspended, wet pit, single-casing diffuser or volute type) |
| Casing form | Diffuser type or volute type; single casing |
| Suction | Submerged below bowl assembly; flooded suction |
| Discharge | Through column to surface |
| Driver | Surface-mounted (motor or engine), dry and accessible |
| Number of stages | Single-stage (VS2 volute type) or multistage option available |
| Impeller type | Single or double suction radial impeller |
| Shaft | Flexible line shaft with intermediate sleeve bearings |
| Thrust bearing | Located in driver or discharge head, absorbs hydraulic axial load |
| Compliance | API 610 11th / 12th edition (ISO 13709) |
Vertical suspended configuration – The pump bowl assembly is submerged in the source, eliminating priming requirements. The surface-mounted motor remains dry and accessible, simplifying maintenance and alignment.
Excellent NPSH characteristics – The submerged impeller significantly improves NPSH available and reduces NPSH required, lowering the risk of cavitation – critical for volatile hydrocarbons, hot liquids, and seawater applications.
Single-casing diffuser or volute design – The bowl section efficiently converts velocity energy to pressure while maintaining smooth hydraulic behavior across the operating range, with stable head-flow curves suitable for parallel operation.
Shaft supported by intermediate sleeve bearings – A multi-piece line shaft transmits power down to the impeller. Bearings are product-lubricated or externally flushed, ensuring alignment, reducing vibration, and supporting reliable operation even in long settings.
Double-suction first-stage impeller (optional) – Improves cavitation resistance and reduces NPSH required, protecting against vibration and cavitation damage.
Low NPSH 1st-stage hydraulics – Unique low NPSH first-stage impeller followed by a high head per stage series hydraulics design, reducing the number of stages required, shortening the pump, and lowering associated civil costs.
| Parameter | Range |
|---|---|
| Flow (capacities) | Up to 10,000 m³/h (44,000 GPM) – larger sizes on request |
| Head | Up to 150 m (490 ft) – single-stage typical; multistage options for higher head |
| Discharge pressure | Up to 15 bar (218 psi) – standard; up to 78 bar on request |
| Temperature range | -30°C to +250°C (-22°F to +482°F) |
| Setting depth (column length) | Up to 50 m (custom on request) |
| Number of stages | Single-stage (VS2 volute type) or multistage (up to 10 stages) |
| Speed | Up to 3,600 rpm |
| Flange rating | ANSI Class 150 / 300 (raised face) as required |
| Driver | Electric motor (NEMA / IEC) or diesel engine |
| Design life | 20 years minimum |
Seawater and raw water (especially brackish or chlorinated) are corrosive to carbon steel. Material selection is critical for long service life in deep well and seawater intake applications.
| Component | Standard Material | Upgrade Option | Remarks |
|---|---|---|---|
| Column & discharge head | Carbon steel with epoxy coating | 316L stainless steel / duplex | Carbon steel economical for fresh water; 316L/duplex required for seawater |
| Bowl assembly (diffuser/volute) | 316L stainless steel (CF3M) | Duplex 2205 / super duplex 2507 | Seawater wetted; corrosion-resistant materials mandatory |
| Impeller | 316L stainless steel (CF3M) | Duplex 2205 / super duplex / bronze | 316L suitable for raw water; duplex for high chloride seawater |
| Shaft (enclosed tube) | 410 stainless steel (fresh water) / duplex (seawater) | Super duplex 2507 | For seawater-exposed shafting |
| Shaft enclosing tube (if used) | 316L stainless steel | Duplex | Protects shaft from seawater |
| Shaft sleeve | 420 stainless steel | 316L / duplex | Wear‑resistant |
| Wear rings | 316L + Stellite hard-facing | Tungsten carbide | – |
| Intermediate line shaft bearings | Product-lubricated cutless rubber (bronze-backed) | Silicon carbide / PTFE | Seawater‑lubricated |
| Thrust bearing (in driver) | Heavy-duty angular contact | Tilt‑pad Kingsbury | – |
| Fasteners | 316 stainless steel | Duplex | – |
Fresh water / low chloride raw water: Carbon steel column + 316L stainless steel bowl, impeller, and shaft sleeves. This is the most cost‑effective combination for municipal raw water, river intake, and fresh water deep wells.
Standard seawater (chlorides 15,000-30,000 ppm): 316L stainless steel (S‑8) wetted parts (bowl, impeller, shaft). 316L provides good resistance to seawater corrosion and is the most widely used material for seawater intake and cooling water pumps in coastal power plants. Type 316L stainless steel (UNS S31603) plus cathodic protection (CP) has been adapted as a cost‑effective solution to ensure long service life for large seawater circulating water pumps.
Aggressive seawater (high velocity, warm, high salinity): Duplex 2205 (D‑1) – PREN 35, superior resistance to pitting and crevice corrosion compared to 316L (PREN 23). Duplex 2205 is recommended for more aggressive environments where 316L may show pitting over long periods.
Severe seawater conditions (high chloride, splash zone, difficult maintenance): Super duplex 2507 (D‑2 / U‑8) – PREN >40, the most resistant among common seawater pump materials. High strength and good corrosion resistance enable weight and cost savings. Super duplex 2507 requires no additional corrosion protection measures when proper heat treatment, surface finishing, and pickling/passivation are performed.
Material selection logic for seawater service – PREN values: 316L ~23, duplex 2205 ~35, super duplex 2507 ~40. Among these materials, only alloy 2507 requires no additional corrosion protection measures (normally cathodic protection). Both Type 316L SS and Alloy 2205 require additional corrosion protection measures for long‑term seawater service where internal CP is applicable. For pumps where adding CP is not feasible, pump integrity relies on the chosen material, good fabrication practices, and proper operation patterns. For high‑chloride environments, super duplex materials have the best resistance to both general and localized corrosion.
All materials supplied with EN 10204 Type 3.1 certification and full traceability. PMI (Positive Material Identification) available for alloy verification.
For VS2 deep well pumps, sealing is typically at the stuffing box in the discharge head above grade. The mechanical seal design follows API 682 and depends on the shut‑off head and pumped liquid.
| Seal Arrangement | API 682 Plan | Suitability |
|---|---|---|
| Single cartridge seal with self-flush | Plan 11 (or Plan 13 for deep settings) | Standard – simple, reliable for clean water and seawater |
| Single seal with external flush | Plan 32 | For abrasive or saline water – external clean flush prevents solids/crystals from entering seal faces |
| Dual pressurized (Arrangement 3) | Plan 53B | Zero emissions; recommended for hazardous or toxic liquids |
| Tandem seal (Arrangement 2) | Plan 52 | For critical applications where leakage prevention is essential |
Seal faces: Silicon carbide vs. silicon carbide (hard‑on‑hard) recommended for seawater and abrasive raw water. Elastomers: Viton (FKM) or EPDM (for fresh water).
For deep wells with very long column lengths (exceeding seal capabilities), the pump may be supplied with lantern ring and packing instead of a mechanical seal, providing reliable sealing in applications where the stuffing box is submerged.
The VS2 pump provides excellent NPSH characteristics because the suction inlet is submerged and the impeller is located at depth, providing positive head from the water column above it.
Submerged impeller – Eliminates NPSH problems common with horizontal pumps mounted above the water source. The inlet remains under a positive head at all times.
Low NPSH first-stage hydraulics – Sulzer’s VS2 series features a low NPSH first-stage, followed by unique high head per stage series hydraulics, minimizing the number of stages required and reducing pump length and associated civil costs.
Double‑suction first-stage impeller option – Further reduces NPSH required. Double suction on larger sizes can reduce pump length.
No priming required – The pump is self‑priming by virtue of being submerged. There is no need for foot valves, vacuum systems, or manual priming.
| Industry / Setting | Specific Service |
|---|---|
| Municipal water supply | Raw water extraction from deep wells, boreholes, and river intakes |
| Desalination plants | Seawater intake from beach wells or open ocean intakes |
| Coastal power plants | Cooling water circulation (once‑through cooling) from seawater intake caissons |
| Industrial water | Raw water supply for refineries, petrochemical plants, steel mills |
| Irrigation | Deep well pumping for agricultural irrigation systems |
| Offshore platforms (FPSO) | Seawater lift to deck, firewater, and service water |
| LNG terminals | Seawater supply to open‑rack vaporizers |
| Mine dewatering | Groundwater lowering and sump dewatering |
| Flood control & drainage | Large volume pumping from sumps and wet pits |
API 610 full compliance (VS2) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.
Vertical submerged configuration – Eliminates priming, no foot valve required, excellent NPSH characteristics.
Surface-mounted driver – Motor remains dry and accessible; no submersible motor required for deep wells.
Double-suction first-stage impeller option – Reduces NPSH required, protects against cavitation damage and vibration.
Material flexibility – 316L stainless steel (S‑8) for raw water and seawater; duplex (D‑1) and super duplex (D‑2/U‑8) for aggressive seawater.
Excellent NPSH characteristics – Low NPSH 1st-stage hydraulics minimize pump length and reduce civil costs.
High efficiency with reduced power consumption – Modular construction to fit project-specific nozzle location requirements.
Long service life – Designed for continuous heavy‑duty operation with minimal downtime.
Easy maintenance – Driver removal without disturbing column; accessible shaft couplings for inspection.
Proven in service – Thousands of VS2 pumps installed in raw water, deep well, and seawater intake applications worldwide.
Hydrostatic test – Casing, bowl, and discharge head tested at 1.5× design pressure.
Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).
Mechanical run test – 4 hours minimum continuous operation; vibration and bearing temperature recorded.
NPSH test – Optional, when specified.
Impeller dynamic balancing – Grade G6.3 or better.
Material certification – EN 10204 3.1 for all pressure‑containing and wetted parts.
NDE – Dye penetrant (PT) on castings; ultrasonic (UT) on shafts; as required by API 610.
Third‑party inspection – Available (DNV, Lloyds, BV, SGS).
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 11/13 ready) | 1 set |
| Thrust bearing set (driver or discharge head) | 1 set |
| Intermediate line shaft bearing set (per column section) | 1 set per 2‑3 metres of column |
| Wear ring set (casing + impeller) | 1 set |
| Impeller | 1 (for critical duty) |
| Shaft sleeve | 1 |
| Gasket / O‑ring kit (full set) | 1 set |
For detailed selection of the correct API 610 VS2 raw water / seawater deep well pump for your deep well, seawater intake, or raw water project – including flow, head, well depth/setting depth, water chemistry (fresh, brackish, or seawater chloride concentration), NPSHa, material selection (316L vs. duplex vs. super duplex), and driver type – please contact our engineering team.
Email: info@hyrig.com
*Our API 610 VS2 raw water / seawater deep well pumps are specifically engineered for deep set, high‑reliability water intake applications – handling flows to 10,000 m³/h, heads to 150 m, and column lengths to 50 metres. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with vertical turbine construction, surface‑mounted driver, low‑NPSH hydraulics, and material options for fresh water, raw water, and aggressive seawater.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.