API 610 OH1/OH2 seawater lift pump – horizontal, overhung, single‑stage centrifugal pump engineered for large volume seawater intake and lift service in coastal power plants, desalination facilities, LNG terminals, offshore platforms, and industrial cooling water systems. Available in OH1 foot‑mounted (ambient) and OH2 centreline‑mounted (hot climates) configurations. High flow, medium‑low head design: flows to 2,000 m³/h, heads to 60 m. Robust carbon steel casing with 316L stainless steel internals (impeller, shaft sleeve, wear rings), or full 316L stainless steel wetted parts for severe corrosion resistance. Back pull‑out design, API 682 mechanical seals with Plan 11 or Plan 53B for zero emissions. Manufactured by a certified China API 610 pump manufacturer with API Q1 certification. 20‑year design life, 3‑year continuous operation.

Conatct For Details
DetailReview(0)Additional

Product Overview

A seawater lift pump (also called a cooling water intake pump or seawater supply pump) is a critical, large‑flow centrifugal pump used to lift or transfer seawater from the sea, river estuary, or open ocean to coastal industrial facilities. Typical applications include cooling water supply for coastal power plants, intake for reverse osmosis desalination plants, cooling loops for LNG regasification terminals, fire water and service water for offshore platforms, and once‑through cooling for steel mills or chemical plants. Because the pump is located near the shore, often on a jetty or onshore sump, it must handle large volumes of seawater (up to 2,000 m³/h) at relatively low heads (10‑60 metres), operate continuously, and withstand the highly corrosive nature of salt water.

The pump is classified under API 610 (ISO 13709) as Type OH1 (foot‑mounted) or OH2 (centreline‑mounted). The OH1 configuration is suitable for most seawater lift applications where water temperature is ambient (5‑40°C). The OH2 centreline‑mounted configuration is recommended for hot climates or when seawater temperature can exceed 60°C (e.g., power plants with heated discharge recirculation) to prevent thermal misalignment. Both are overhung, radially split, single‑stage, end‑suction centrifugal pumps with back pull‑out design – crucial for maintenance in remote coastal locations.

This pump is manufactured by a leading China API 610 pump manufacturer with full API Q1 certification, decades of experience in severe‑duty pumping, and thousands of seawater intake pumps installed worldwide.

OH1 vs. OH2 Configuration for Seawater Lift

FeatureOH1 (Foot‑mounted)OH2 (Centreline‑mounted)
MountingFeet on casing bottom bolted to baseplateFeet on casing centreline bolted to baseplate
Thermal expansionCasing expands downward; slight shaft riseCasing expands uniformly; shaft alignment maintained
Temperature rangeUp to 60°C (140°F) – typical ambient seawaterUp to 100°C (212°F) – for heated seawater recirculation or tropical climates
Best forStandard seawater intake (coastal power/desalination)Hot seawater or when pump may see wide temperature swings from standby to operation
API 610 TypeOH1OH2

which one to choose for seawater lift?

  • Most seawater lift projects use OH1 foot‑mounted pumps because seawater is cool (5‑35°C) and thermal expansion is minimal. OH1 is simpler and cost‑effective.

  • OH2 centreline‑mounting may be specified for very hot climates where seawater temperature can exceed 50°C (e.g., Arabian Gulf, Red Sea) or for pumps that may see rapid temperature changes (e.g., intermittent operation with solar heated water in suction pit).

Construction & API 610 Classification

FeatureDescription
API 610 TypeOH1 (foot‑mounted) or OH2 (centreline‑mounted)
Casing formRadially split, single volute or double volute (for larger sizes > 500 m³/h)
Bearing supportOverhung – impeller overhangs from bearing housing; bearings at drive end
Number of stagesSingle stage
Suction typeEnd suction, single‑suction (large eye for low NPSHr)
Discharge orientationTop or side discharge (vertical or horizontal)
Flange ratingANSI Class 150 / 300 (seawater lift pressure typically 6‑10 bar)
ComplianceAPI 610 11th / 12th edition (ISO 13709)

Back pull‑out design – The entire rotating assembly (impeller, shaft, bearing housing, mechanical seal) can be removed without disturbing suction or discharge piping. This is essential for coastal pumps that may be exposed to marine fouling or sand ingress.

Heavy‑duty bearing housing – Oil bath lubrication, fins for cooling. L10 bearing life ≥25,000 hours per API 610. For seawater lift with low NPSH, the pump often runs at lower speed (980/1,450 rpm) to reduce NPSHr and erosion.

Impeller – Closed (enclosed) radial type for high efficiency at large flows. For handling fine sand or marine life, use open or semi‑open impeller with larger clearances. Standard: closed impeller (for clean seawater, screened intake). Optional: semi‑open or open impeller for unscreened intakes.

Wear rings – Replaceable; made of 316L SS + Stellite hard‑facing for long life against sea sand abrasion.

Key Technical Specifications (Seawater Lift Duty – High Flow, Medium‑Low Head)

ParameterOH1 / OH2
Flow range100 – 2,000 m³/h (440 – 8,800 GPM) – typical 200‑1,500 m³/h
Head range10 – 60 m (33 – 195 ft) – typical 15‑40 m
Max temperature (OH1)Up to 60°C (140°F)
Max temperature (OH2)Up to 100°C (212°F)
Pressure ratingUp to 1.6 – 2.5 MPa (16‑25 bar) – far above lift requirements
Speed980 / 1,450 rpm (50Hz) or 1,200 / 1,800 / 2,400 rpm (60Hz) – slower speeds preferred for large flows and low NPSH
NPSHrVery low (2‑4 m) due to large‑eye, low‑specific‑speed design – essential for vertical suction lifts from tidal basins
Pump efficiencyUp to 88% at BEP (large flows)
Design life20 years minimum

Materials – Carbon Steel + 316L Internals or All‑316L

Seawater is highly corrosive due to chlorides. The choice of material depends on the aggressiveness of the seawater and the required service life.

ComponentOption 1 (Economical – Carbon Steel Casing + 316L Internals)Option 2 (Premium – Full 316L Stainless Steel)Remarks
CasingCarbon steel (C‑6) with epoxy coating316L stainless steel (S‑8)Carbon steel coating must be perfect; any pinhole leads to rapid localised corrosion from chlorides. Full 316L is safer for long life, especially for seawater with chlorides >20,000 ppm.
Impeller316L stainless steel316L stainless steelSame – both options use 316L impeller for corrosion resistance.
Shaft316 stainless steel (coated)316 stainless steel or duplexSame – 316 is minimum for seawater wetted surfaces.
Wear rings316L + Stellite316L + StelliteSame.
Shaft sleeve316 stainless steel316 stainless steel or duplexSame.
Fasteners316 stainless steel316 stainless steel / duplexSame.
Gaskets / O‑ringsPTFE or VitonPTFE or VitonBoth use non‑asbestos, seawater‑compatible seals.

Material recommendations for seawater lift

  • Standard coastal seawater (chlorides 15,000‑30,000 ppm, moderate temperature) : Carbon steel casing with epoxy coating + 316L stainless steel internals works well for 20+ years if the coating is properly maintained and there is no mechanical damage. This is the most cost‑effective choice in many projects.

  • Aggressive seawater (high velocity, warm, high salinity, or with abrasive sand) : Full 316L stainless steel wetted parts (casing also 316L) is strongly recommended to avoid coating failure and corrosion. Over the life of the pump (20 years), the extra upfront cost is justified by reduced maintenance and reliability.

  • For offshore platforms or very remote locations where maintenance is difficult : Super duplex (D‑1) may be specified, though higher cost; however, for most industrial seawater lift, 316L is sufficient.

Our standard offering for seawater lift is Option 1: carbon steel casing with 316L stainless steel impeller, shaft sleeve, and wear rings. This provides corrosion resistance where it matters most – the high‑velocity internal parts. Option 2 (all‑316L) is available on request.

Mechanical Seals – API 682 Plan 53B (Recommended for Seawater) or Plan 11

Seawater contains chlorides and often fine sand, which can cause conventional single seals to leak or corrode. For zero leakage and long life, a dual pressurised seal (API 682 Arrangement 3) with Plan 53B is recommended.

Seal ArrangementAPI 682 PlanSuitability for Seawater Lift
Dual pressurised (Arrangement 3)Plan 53BRecommended – barrier fluid pressurised above pump pressure; zero seawater leakage; barrier fluid isolates seal faces from seawater, preventing corrosion and salt buildup
Tandem seal (Arrangement 2)Plan 52Acceptable; buffer fluid collects any leakage; less positive isolation
Single seal (Arrangement 1)Plan 11 (self‑flush)Not recommended for seawater because salt will crystallise on seal faces and corrode the seal chamber

Plan 53B uses a nitrogen‑charged bladder accumulator to keep barrier fluid (e.g., glycol/water mixture or oil) at a pressure higher than pump suction pressure. The barrier fluid circulates, removing heat and preventing seawater ingress. This arrangement greatly extends seal life and eliminates visible leakage – important for environmental compliance at coastal sites.

Seal faces: Silicon carbide vs. silicon carbide (hard‑on‑hard) – resistant to abrasion from sand. Elastomers: Viton (FKM) or PTFE.

NPSH and Suction Conditions for Seawater Lift

Seawater lift pumps often take suction from a tidal basin, sump, or concrete intake structure with varying water levels. NPSHa may be limited during low tide or when the pump is installed on a jetty with high suction lift.

  • Large eye impeller – Low suction‑specific speed reduces NPSHr.

  • Inducer option – For very low NPSHa (<3 m), an axial inducer can reduce NPSHr further (no more than 1.5 m). Not typically required for most seawater lift if the basin is well designed.

  • Submerged suction – If the pump is installed below the minimum water level (flooded suction), NPSHa is excellent. However, many seawater lifts use vertical pumps (VS4/VS6) for those conditions. For horizontal OH1/OH2 pumps, they must be located above the water level? Actually, horizontal pumps can be installed below grade in a dry pit with flooded suction. We assume operation with positive suction head. Ensure NPSHa ≥ NPSHr + 1.0 m.

Seawater Lift Performance Curve Characteristics

  • Flat head‑flow curve – For high flow, low head duty, the pump curve should be stable, with head dropping gradually as flow increases.

  • Non‑overloading power – Motor power should not exceed rated power over the entire operating range, even at shut‑off.

  • High efficiency – At best efficiency point, efficiency exceeds 80% for large pumps.

Applications for Seawater Lift Pump

Industry / FacilitySpecific Service
Coastal power plantsCooling water intake for once‑through cooling of condensers and auxiliary cooling
Seawater desalination plants (SWRO)Intake lift to pretreatment and reverse osmosis high‑pressure pumps
LNG receiving terminalsSeawater for vaporisers (open rack vaporisers) and auxiliary cooling
Offshore platforms (FPSO / fixed platforms)Seawater lift from sea chest to deck for cooling, fire water, and process
Coastal industrial plantsCooling water intake for steel mills, refineries, petrochemicals
Marine / shipbuildingBallast pumps, fire pumps, cooling water pumps (but often vertical in‑line)

Why Choose an API 610 OH1/OH2 Seawater Lift Pump from This China Manufacturer

  • API 610 full compliance (OH1/OH2) – 11th/12th edition ISO 13709, 20‑year design life, 3‑year continuous operation.

  • High flow, medium‑low head capability – Flows to 2,000 m³/h, heads to 60 m – optimal for seawater intake.

  • Back pull‑out design – Easy maintenance without removing piping – essential for coastal maintenance access.

  • Material options – Economical carbon steel casing + 316L internals, or full 316L for aggressive seawater.

  • API 682 Plan 53B dual seals – Zero seawater leakage, barrier fluid protection against corrosion and crystals.

  • Low NPSH design – Large‑eye impeller, inducer option; ensures reliable operation during low tide.

  • High efficiency – Up to 88% at BEP, reducing energy costs over decades of continuous operation.

  • Certified China manufacturer – API Q1, ISO 9001, with global references in seawater lift.

  • Proven in coastal service – Thousands of OH1/OH2 pumps installed on coastlines worldwide.

Quality Assurance & Testing

  • Hydrostatic test – Casing tested at 1.5× design pressure.

  • Performance test – Water at rated speed per API 610 Grade 2 (Grade 1 optional).

  • Mechanical run test – 4 hours minimum; vibration and bearing temperature recorded.

  • Impeller dynamic balancing – Grade G6.3.

  • Material certification – EN 10204 3.1 for all wetted parts; PMI available for 316L verification.

  • Corrosion protection coating inspection – For carbon steel casing, dry film thickness and holiday testing.

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (API 682 Plan 53B ready)1 set
Bearing set (radial + thrust)1 set
Wear ring set (casing + impeller) – 316L + Stellite1 set
Impeller (316L)1 set
Shaft sleeve (316 stainless)1
Gasket / O‑ring kit (full set)1 set
Inducer (if fitted)1 set

Get a Quote or Engineering Support

For detailed selection of the correct API 610 OH1/OH2 seawater lift pump for your coastal project – including flow, head (tidal range), water temperature, chloride concentration, NPSHa, material choice (carbon steel/316L or full 316L), and API 682 seal plan – please contact our engineering team.

Email: info@hyrig.com

*Our API 610 OH1/OH2 seawater lift pumps are specifically engineered for high‑flow, medium‑low head seawater intake – handling up to 2,000 m³/h with minimal NPSH and long corrosion‑free life. Manufactured by a leading China API 610 pump manufacturer, API Q1 certified, with back pull‑out design, dual pressurised seals (Plan 53B) and material options for aggressive coastal environments.*


Comment