Our self‑priming pump is designed and manufactured according to API 610 11th/12th edition (ISO 13709) , the most stringent standard for centrifugal pumps in petroleum, petrochemical, and natural gas industries.
Key API 610 requirements met:
Design life: 20 years minimum
Continuous operation: ≥3 years uninterrupted
Bearing life: L10 ≥25,000 hours
Critical speed: First lateral critical speed ≥120% of maximum operating speed
Centreline mounting (OH2 configuration) – accommodates thermal expansion
Nozzle loads – meeting API 610 allowable values
| Feature | OH1 | OH2 |
|---|---|---|
| Mounting | Foot‑mounted | Centreline‑mounted |
| Thermal growth handling | Less suitable for hot service | Excellent (feet on centreline) |
| Typical temperature range | –20°C to +150°C | –45°C to +400°C |
| Best for | Moderate temperature | High‑temperature applications |
The seal chamber is API 682 (4th edition) compliant, accepting all arrangements:
Arrangement 1 (single seal) – Plan 11, 21, 23
Arrangement 2 (tandem) – Plan 52
Arrangement 3 (dual pressurised) – Plan 53B, 53A
Available for hazardous areas: ATEX II 2G Ex h IIB T4 (gas) and II 2D Ex h IIIC T120°C (dust). Certified as equipment for explosive atmospheres.
CE – Conforms to European machinery directive 2006/42/EC
NACE MR0175 / ISO 15156 – For sour service (H₂S)
PED 2014/68/EU – Pressure equipment directive (optional)
WRAS / NSF 61 – For potable water applications (on request)