All pumps are tested in accordance with API 610 11th/12th edition requirements.
1. Hydrostatic test
Pressure casing tested at 1.5 × design pressure
Hold time: 30 minutes minimum
No leakage permitted
2. Performance test
Test fluid: water at rated speed
Grade: API 610 Grade 2 (Grade 1 optional)
Head, flow, power, efficiency measured at five points (shut‑off to >110% BEP)
Tolerance: per API 610 Table 24
3. NPSH test (when specified)
Full NPSH curve at rated speed
Verification at 3% head drop
4. Mechanical run test
Minimum 4 hours continuous at rated speed
Vibration velocity measured per API 610 limits
Bearing temperature rise monitored (max 40°C above ambient)
| Component | NDE method | Acceptance criteria |
|---|---|---|
| Casing (pressure‑containing) | Magnetic Particle (MPI) or Dye Penetrant (DP) | API 610, no relevant indications |
| Shaft | Ultrasonic (UT) or MPI | API 610, no cracks |
| Impeller | Visual & MPI (if cast) | No porosity >2mm |
EN 10204 Type 3.1 – full traceability with chemical and mechanical test reports for all wetted parts.
Positive Material Identification (PMI) – available on request for alloy verification.
Inspection by customer or third party (e.g., DNV, BV, Lloyds) can be arranged. All test reports are provided with each pump.
Certified performance curve
Hydrostatic test certificate
Material certificates (EN 10204 3.1)
Dimensional outline drawing
Cross‑sectional drawing
Instruction manual
For any inquiries, please contact: info@hyrig.com