Fill the casing with liquid through the priming port. Ensure the stored liquid volume is adequate (mark on casing).
Close discharge valve partially (about 30% open) to reduce starting load.
Start motor – pump should prime within 2‑3 minutes (depending on suction lift).
Open discharge valve slowly to operating point.
Check for leaks at mechanical seal, flanges, and drain plugs.
Suction line – no air leaks (visible liquid drips or pressure instability).
Stored liquid – ensure casing has not lost liquid (through evaporation or leak).
Vibration and bearing temperature – compare to baseline.
Mechanical seal – no visible dripping from seal chamber drain.
| Component | Lubricant | Quantity | Change interval |
|---|---|---|---|
| Bearing housing (oil bath) | ISO VG 68 synthetic or mineral | To oil level indicator | 8,000 hours or 1 year |
| Grease‑lubricated bearings | NLGI 2 lithium complex | Fill cavity 30‑50% | 2,000 hours (high speed) |
Isolate pump, drain casing.
Remove coupling guard, disconnect spacer coupling.
Unbolt bearing housing from casing.
Pull rotating assembly (shaft, bearings, seal chamber) out of casing.
Remove old seal cartridge, install new API 682 cartridge.
Re‑assemble – no alignment needed because cartridge is pre‑set.
| Problem | Likely cause | Remedy |
|---|---|---|
| Pump does not prime | Casing lost stored liquid, suction air leak, recirculation port blocked | Refill casing, tighten suction joints, clean port |
| Priming too slow | Suction pipe too long/diameter too large, low impeller speed | Shorten pipe, install larger impeller, check voltage |
| Pump loses prime after running | Air leak in suction line, vortexing at strainer | Repair leak, lower strainer or increase submergence |
| Low flow / head | Impeller or wear ring worn, voltage low, suction strainer clogged | Replace wear parts, check supply voltage, clean strainer |
| Excessive vibration | Cavitation (NPSH insufficient), misalignment, impeller imbalance | Increase NPSHa, re‑align, balance impeller |
Drain completely, flush with clean water/inhibitor.
Apply rust preventive to machined surfaces.
Rotate shaft manually monthly to prevent bearing brinelling.
Store in dry, covered area.
For any inquiries, please contact: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.