Overview
The tubing valve, also named tubing cock, is a manual safety valve specifically designed for tubing strings in oil and gas wells. When open, drilling fluid (or produced fluids) can flow through the valve with virtually no pressure drop, ensuring unrestricted production or circulation. This valve is installed above the tubing string to serve two critical functions: to control blowout (well pressure) and to prevent loss of drilling fluid when disassembling tubing during workover, completion, or well servicing operations. The tubing valve provides a positive shut‑off at the top of the tubing string, protecting the rig floor and personnel from unexpected pressure releases.
Key Features
Full‑Bore Flow – When open, the valve presents minimal flow restriction, allowing fluid to pass with negligible pressure drop.
Bidirectional Sealing – Seals pressure from above or below, suitable for both production and well control applications.
Manual Operation – Simple quarter‑turn or multi‑turn mechanism operated with a standard wrench or handle.
Blowout Control – Installed above tubing to provide a rapid shut‑off in case of a tubing‑head pressure event.
Fluid Loss Prevention – Prevents expensive drilling fluid or completion fluid from draining into the well when tubing is disconnected.
Multiple Connection Sizes – Available with API UPTBG threads (2-7/8″, 3-1/2″, 4-1/2″) and 2″ 1502 Weco hammer union connections.
Working Principle
The tubing valve is typically a ball valve or gate valve design. In the open position, the internal bore is aligned with the tubing ID, allowing unrestricted fluid flow. When the valve is closed, the internal sealing element (ball or gate) rotates or slides across the bore, creating a pressure‑tight seal. The valve is designed to hold rated working pressure (35 MPa / 5,000 psi) from either direction. During normal production or circulation, the valve remains open. When tubing must be disconnected (e.g., to change packers, pull tubing, or perform wireline work), the valve is closed manually at the surface, trapping fluid below and preventing spillage or loss. In the event of a tubing‑head pressure increase (blowout potential), the valve can be closed immediately to kill the well from the top.
Technical Specifications
| Model | OD mm (inch) | ID mm (inch) | Upper End Connection (API) | Lower End Connection (API) | Working Pressure MPa (psi) |
|---|---|---|---|---|---|
| XSY105 | 105 (4-1/8) | 40 (1-37/64) | 2-7/8 UPTBG | 2-7/8 UPTBG | 35 (5,000) |
| XSY127 | 127 (5) | 44.5 (1-3/4) | 3-1/2 UPTBG | 3-1/2 UPTBG | 35 (5,000) |
| XSY130 | 130 (5-1/8) | 50 (1-31/32) | 3-1/2 UPTBG | 2″ 1502 Weco | 35 (5,000) |
| XSY140 | 140 (5-1/2) | 50 (1-31/32) | 4-1/2 UPTBG | 2″ 1502 Weco | 35 (5,000) |
Note: Other sizes, pressure ratings, and connections are available upon request – refer to the technical agreement for details.
Applications
Installed above the tubing string on production wells, injection wells, and workover/completion operations
Provides blowout prevention during wireline, coiled tubing, or snubbing operations
Prevents drilling fluid, completion brine, or produced fluid loss when disconnecting surface equipment
Suitable for onshore and offshore wells, including HPHT wells (35 MPa / 5,000 psi rating)
Can be used as a backup safety valve in conjunction with surface BOPs and tubing heads
Value Proposition
Zero Pressure Drop – Full‑bore design ensures no production or circulation restriction when open.
Rapid Well Control – Manual closure provides immediate shut‑off in emergency situations.
Fluid Conservation – Prevents costly fluid loss to the wellbore, saving money and reducing environmental risk.
Simple & Reliable – No external power required; mechanical operation is intuitive and dependable.
Versatile Connections – Models available with standard UPTBG tubing threads and 1502 Weco hammer unions for easy integration into existing wellhead assemblies.
The tubing valve (tubing cock) is a simple but essential safety device for any tubing string. By installing this valve above the tubing, operators gain a reliable, manually‑operated shut‑off that controls blowouts, prevents fluid loss, and enhances overall well safety during servicing operations.
Contact Us
For technical data sheets, connection compatibility advice, or a quotation, please contact:
Email: info@hyrig.com
Tubing Valve – Full flow when open, positive seal when closed.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.