Overview
The retrievable drop‑in check valve is an inside blowout control valve designed for drilling operations. It consists of two main components: a landing sub and a retrievable drop‑in check valve assembly. The landing sub is connected at the desired position in the drill string and run into the well. Later, if well control conditions require, the check valve assembly can be dropped (pumped or gravity‑fed) down the drill string until it seats automatically in the landing sub. This valve is a check valve that prevents backflow when a well kick occurs, yet it allows liquid to be injected downward into the circulation well for most conventional drilling operations. The retrievable drop‑in check valve provides effective pressure control while drilling and significantly improves and simplifies well control procedures. As long as the check valve is dropped in, it automatically locks into place on the landing sub, achieving blowout prevention. Additionally, the disassembly of this check valve saves a great deal of manpower and material resources compared to previous drop‑in check valve designs.
Key Features
Two‑Component Design – Landing sub installed in drill string; drop‑in valve assembly retrievable and replaceable.
Automatic Seating – Valve assembly self‑locates and seals in the landing sub when dropped.
Backflow Prevention – Check valve closes instantly when reverse flow (well kick) occurs.
Downward Injection Permitted – Allows normal forward circulation and fluid injection.
Improved Well Control – Simplifies well control procedures; provides a reliable downhole barrier.
Manpower & Material Savings – Easy retrieval and disassembly reduce operational costs compared to older designs.
Multiple Models – Available for 121 mm to 168 mm drill string sizes with NC38 and NC50 connections.
Working Principle
The landing sub is installed in the drill string at a predetermined depth. Under normal drilling conditions, the drop‑in check valve assembly is not present in the string, allowing full‑bore circulation. When a well kick or other well control situation occurs, or when it is desired to install a downhole check valve, the operator drops the valve assembly from the surface. The assembly travels down the drill string by gravity or pump pressure until it reaches the landing sub. The landing sub has an internal profile that matches the valve assembly, causing the valve to automatically seat and lock. Once seated, the valve functions as a spring‑assisted or flow‑sensitive check valve: forward (downward) circulation pushes the valve open, while any reverse (upward) flow – such as from a kick – forces the valve closed, sealing the drill string bore and preventing blowout through the pipe. The valve can be retrieved later by running a spearing tool, pulling the assembly to the surface for inspection or reuse.
Technical Specifications
| Model | Valve Assembly OD mm (inch) | Landing Sub OD mm (inch) | Landing Sub ID mm (inch) | Working Pressure MPa (psi) | OAL mm (ft) | Connection |
|---|---|---|---|---|---|---|
| HFT121 | 60.5 (2-3/8) | 121 (4-3/4) | 50.8 (2) | 35~70 (5,000~10,000) | 776 (2.5) | NC38 |
| HFT127 | 60.5 (2-3/8) | 127 (5) | 50.8 (2) | 35~70 (5,000~10,000) | 776 (2.5) | NC38 |
| HFT165 | 73 (2-7/8) | 165 (6-1/2) | 71.4 (2-13/16) | 35~70 (5,000~10,000) | 804 (2.6) | NC50 |
| HFT168 | 73 (2-7/8) | 168 (6-5/8) | 71.4 (2-13/16) | 35~70 (5,000~10,000) | 804 (2.6) | NC50 |
Note: Custom specifications and other connections are available upon request – refer to the technical agreement for details.
Applications
Onshore and offshore drilling operations requiring a downhole check valve that can be installed and retrieved without tripping the drill string.
Wells with potential for well kicks, swabbing, or loss of circulation where a temporary inside blowout preventer is needed.
Used as a secondary well control barrier in conjunction with surface BOPs and IBOP valves.
Situations where manpower and material savings are desired compared to traditional drop‑in valves.
Value Proposition
Simplified Well Control – Drop the valve only when needed; no need to trip out to install a fixed check valve.
Automatic Blowout Protection – Valve seats automatically and closes on reverse flow, providing immediate downhole shut‑off.
Cost Effective – Retrievable and reusable; disassembly saves significant manpower and material vs. older designs.
Full‑Bore Circulation When Open – Minimal flow restriction during normal drilling.
Versatile Sizing – Four models cover common drill string sizes from 4‑3/4″ to 6‑5/8″ with NC38 and NC50 connections.
The retrievable drop‑in check valve is an innovative well control tool that combines the reliability of a downhole check valve with the operational convenience of a drop‑in, retrievable design. By keeping the landing sub permanently in the drill string and dropping the valve assembly only when needed, operators gain a flexible, cost‑effective inside blowout prevention solution.
Contact Us
For technical data sheets, landing sub installation guidance, or a quotation, please contact:
Email: info@hyrig.com
Retrievable Drop‑In Check Valve – Drop it when you need it, retrieve it when you don’t.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.