Drop-In Check Valve – Complete Product Introduction

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Drop‑in check valve is an inside blowout control valve that can also be used for cutting off drill pipe on all kinds of offshore drilling floating equipment. It consists of a landing sub and a drop‑in valve assembly. The landing sub is connected at the required position in the drill string and run into the well. The check valve assembly is stored on the platform. When a blowout signal is detected, the valve is dropped into the drill pipe and pumped down until it seats in the landing sub. When high pressure flow upwells, the check valve cuts off the high‑pressure flow injected upward in the drill string, thereby achieving blowout prevention. Working pressure 35–70 MPa (5,000–10,000 psi). Available in nine models from FT105 to FT203 with API connections NC31, NC38, NC46, NC50, 5-1/2 FH, and 6-5/8 FH.

Conatct For Details
DetailReview(0)Additional

Overview
The drop‑in check valve is an inside blowout control valve designed for use in drilling operations, particularly on all kinds of offshore drilling floating equipment (semi‑submersibles, drillships, and jack‑ups). It is also used for cutting off the drill pipe bore during well control emergencies. The system consists of two main components: a landing sub and a drop‑in check valve assembly. The landing sub is connected at the desired position in the drill string and run into the well during normal tripping. The check valve assembly is stored on the platform in a ready‑to‑use condition. When a blowout signal is detected (e.g., a well kick or flowing well), the valve is dropped into the drill pipe from the surface and pumped down until it seats firmly in the landing sub. Once seated, the valve acts as a check valve: when high pressure flow upwells from the formation, the check valve automatically cuts off the high‑pressure flow moving upward inside the drill string, thereby achieving the purpose of blowout prevention.

Key Features

  • Inside Blowout Control – Provides a downhole barrier against upward flow through the drill string.

  • Offshore Floating Rig Compatible – Suitable for all types of floating drilling units where rapid deployment is critical.

  • Landing Sub Pre‑installed – The landing sub is placed in the drill string during normal operations, ready to receive the drop‑in valve.

  • Surface Storage & Deployment – Valve assembly stored on the rig floor; dropped and pumped down only when needed.

  • Automatic Cut‑Off – No surface intervention required after seating; valve closes on reverse flow.

  • Wide Pressure & Size Range – Working pressure 35–70 MPa (5,000–10,000 psi); nine models covering drill pipe sizes from 105 mm to 203 mm OD.

Working Principle
The landing sub is installed in the drill string at a predetermined depth and remains there during drilling. Under normal conditions, the drop‑in check valve assembly is not present, allowing full‑bore circulation. When a well control event occurs (blowout signal), the rig crew drops the valve assembly into the top of the drill pipe. The assembly is then pumped down using drilling fluid until it reaches the landing sub. The landing sub has an internal profile that matches the valve assembly, causing the valve to lock and seal into place. Once seated, the valve functions as a check valve: forward (downward) flow – such as pumping kill mud – is permitted, but any reverse (upward) flow, such as high‑pressure formation fluid entering the drill string, forces the valve closed. The valve seals the bore, cutting off the upward high‑pressure flow and preventing a blowout through the drill pipe. The valve can be retrieved later using a spearing tool if required.

Technical Specifications

ModelValve Assembly OD mm (inch)Landing Sub OD mm (inch)Landing Sub ID mm (inch)Working Pressure MPa (psi)OAL mm (ft)Connection
FT10539 (1-17/32)104.8 (4-1/8)40.5 (1-19/32)35~70 (5,000~10,000)572 (1.9)NC31
FT12151 (2-1/64)121 (4-3/4)53 (2-3/32)35~70 (5,000~10,000)794 (2.6)NC38
FT12752 (2-1/16)127 (5)54 (2-1/8)35~70 (5,000~10,000)794 (2.6)NC38
FT15968 (2-11/16)159 (6-1/4)70 (2-3/4)35~70 (5,000~10,000)867 (2.8)NC46
FT16269 (2-23/32)162 (6-3/8)71.4 (2-13/16)35~70 (5,000~10,000)872 (2.9)NC50
FT16567 (2-41/64)165 (6-1/2)69 (2-23/32)35~70 (5,000~10,000)872 (2.9)NC50
FT16867 (2-41/64)168 (6-5/8)69 (2-23/32)35~70 (5,000~10,000)867 (2.8)NC50
FT19078 (3-5/64)190 (7-1/2)80 (3-9/64)35~70 (5,000~10,000)906 (3.0)5-1/2 FH
FT20374 (2-29/32)203 (8)76.2 (3)35~70 (5,000~10,000)883 (2.9)6-5/8 FH

Note: Custom specifications and other connections are available upon request – refer to the technical agreement for details.

Applications

  • Onshore and offshore drilling, particularly floating rigs (semi‑submersibles, drillships, jack‑ups)

  • Used as an emergency inside blowout preventer when a well kick occurs

  • Cutting off high‑pressure upward flow in the drill string during well control events

  • Can be deployed rapidly without tripping the drill string (landing sub already in place)

  • Suitable for most conventional drilling operations where a downhole check valve is required on demand

Value Proposition

  • Rapid Emergency Response – Valve stored on platform; dropped and pumped down immediately upon blowout signal.

  • No Trip Required – Landing sub pre‑installed; valve can be deployed without pulling the drill string.

  • Automatic Blowout Protection – Once seated, the valve self‑activates on reverse flow, cutting off upward high‑pressure flow.

  • Offshore Optimized – Designed for floating rig dynamics; reliable seating even with vessel motion.

  • Versatile Sizing – Nine models cover a broad range of drill pipe sizes from 4‑1/8″ to 8″ with common API connections.

The drop‑in check valve is an essential well control tool for any drilling operation, especially on offshore floating rigs where rapid deployment and reliability are critical. By keeping the landing sub permanently in the drill string and the valve assembly ready on the platform, operators can respond instantly to blowout signals, drop the valve, and pump it down to seat – providing a dependable downhole barrier against upward high‑pressure flow.

Contact Us
For technical data sheets, deployment procedures, or a quotation, please contact:
Email: info@hyrig.com


Drop‑In Check Valve – Ready on the platform, seated in the string, stopping the blowout.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit