Overview
The kelly valve, also named kelly cock or drill pipe safety valve, is a manual control valve installed in the drill string circulating system. It is one of the most effective tools for preventing blowouts during drilling operations. The kelly valve is divided into two types: the upper kelly valve (used between the swivel sub and the kelly) and the lower kelly valve (used between the lower end of the kelly and the upper end of the drill pipe). Using a special wrench, a 90° rotation of the valve switch achieves on/off operation according to instructions. In normal drilling operations, to avoid malignant accidents such as loss of drilling fluid or blowouts, kelly valves shall be connected on both ends of the kelly, providing a reliable safety barrier at the top of the drill string.
Key Features
Manual Control Valve – Simple, reliable, and does not rely on external power or hydraulic systems.
Upper & Lower Configuration – Installed above and below the kelly for complete isolation capability.
90° Rotation Operation – Quarter‑turn (90°) with a special wrench opens or closes the valve quickly and positively.
High Pressure Rating – Working pressure from 35 MPa to 105 MPa (5,000 psi to 15,000 psi) to suit a wide range of well conditions.
Blowout Prevention – Essential component of the well control system; seals the drill string when a kick occurs.
Multiple Sizes & Connections – Models from 86 mm to 203 mm OD with API connections including NC26, NC31, NC38, NC46, NC50, 4-1/2 REG, 5-1/2 FH, 6-5/8 REG, etc.
Working Principle
The kelly valve is a full‑bore, ball‑type or gate‑type manual valve. In the open position, it allows unrestricted flow of drilling fluid through the kelly and drill string. When a well kick or other emergency occurs, the driller uses a specially designed wrench to rotate the valve stem 90°. This rotation turns the internal ball or gate, sealing off the bore and preventing fluid from flowing upward out of the drill string. The valve is designed to hold pressure from either direction (bidirectional sealing). The upper kelly valve is typically used as the primary surface‑controllable barrier, while the lower kelly valve serves as a backup or as a means to isolate the kelly itself for servicing.
Technical Specifications (Partial Model List)
| Model | OD mm (inch) | ID mm (inch) | Connection (API) | Working Pressure MPa (psi) |
|---|---|---|---|---|
| XS86 | 86 (3-3/8) | 30 (1-3/16) | NC26 B×P | 35~105 (5,000~15,000) |
| XS105 | 105 (4-1/8) | 40 (1-37/64) | NC31 B×P | 35~105 (5,000~15,000) |
| XS111 | 111 (4-3/8) | 40 (1-37/64) | NC31 B×P | 35~105 (5,000~15,000) |
| XS121 | 121 (4-3/4) | 44.5 (1-3/4) | NC38 B×P | 35~105 (5,000~15,000) |
| XS127 | 127 (5) | 44.5 (1-3/4) | NC38 B×P | 35~105 (5,000~15,000) |
| XS146 | 146 (5-3/4) | 44.5 (1-3/4) | 4-1/2 REG LHB×P | 35~105 (5,000~15,000) |
| XS159 | 159 (6-1/4) | 57.2 (2-1/4) | NC46 B×P | 35~105 (5,000~15,000) |
| XS168 | 168 (6-5/8) | 71.4 (2-13/16) | NC50 B×P | 35~105 (5,000~15,000) |
| XS178 | 178 (7) | 71.4 (2-13/16) | 5-1/2 FH B×P | 35~105 (5,000~15,000) |
| XS197 | 197 (7-3/4) | 76.2 (3) | 6-5/8 REG LHB×P | 35~105 (5,000~15,000) |
| XS203 | 203 (8) | 76.2 (3) | 6-5/8 REG LHB×P | 35~105 (5,000~15,000) |
Note: Custom specifications and other connections are available upon request – refer to the technical agreement for details.
Applications
Installed above and below the kelly on any drilling rig (onshore and offshore)
Provides a manual shut‑off valve for the drill string during well control events
Prevents loss of drilling fluid when making connections or when stripping pipe
Serves as a backup safety barrier in conjunction with the top drive IBOP and annular BOP
Suitable for all drilling operations, including vertical, directional, horizontal, and HPHT wells
Value Proposition
Essential Well Control – Mandatory component for safe drilling operations; provides a positive shut‑off at the top of the drill string.
Bidirectional Sealing – Holds pressure from above or below, allowing it to be used in a variety of well control scenarios.
Simple Operation – 90° rotation with a special wrench is quick and requires no complex training.
High Pressure Capability – Rated up to 105 MPa (15,000 psi) to meet the demands of deep and high‑pressure wells.
Wide Model Selection – Multiple sizes and API connections ensure compatibility with most kellys and drill strings.
Durable Construction – Designed for repeated use in harsh drilling environments with minimal maintenance.
The kelly valve (kelly cock / drill pipe safety valve) is a simple, reliable, and essential tool for preventing blowouts and controlling the drill string under pressure. By installing upper and lower kelly valves on both ends of the kelly, operators can safely isolate the drill string, prevent loss of drilling fluid, and respond effectively to well kicks – making it a cornerstone of drilling safety.
Contact Us
For technical data sheets, model selection assistance, or a quotation, please contact:
Email: info@hyrig.com
Kelly Valve – 90° to safety.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.